INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
REMOVE THE CABLE TIES THAT SECURE THE KILLING GRID IN
POSITION BEFORE SWITCHING THE UNIT ON.
Excalibur™Commercial should be mounted as shown in the
mounting options section of this document. Keep out of
reach of children. Use the removable mains cable & plug to
connect Excalibur™Commercial to the main supply. The
power supply should be of an appropriate power rating, as
specified on the specification label found on the catch tray.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every
month. During cleaning the unit should be thoroughly wiped
down with a damp cloth, removing any build up of dirt.
Ensure the unit is completely dry before reconnecting it to the
power supply.
Professional Electric Insect Control
Mounting Options
Wall
Desk
Suspended
(Chain not supplied)
MOUNTING FIXING CENTRES
METHOD EXC 30
Wall 438mm
Desk -
Suspended 506mm
Please read these instructions carefully and store in a safe
place for future reference.
EXCALIBUR™
As part of the Insect-O-Cutor®brand of insect control
products, Excalibur™ Commercial is an effective and flexible
professional flykiller which utilises highly effective UV tubes.
Constructed from stainless steel and UV stable polycarbonate,
Excalibur™ Commercial can be wall mounted, ceiling
suspended or free standing.
Contents of package
- 1 x Excalibur™Commercial flykiller
- 1 x Mains cable (Type X)
- 2 x High powered UV tubes (Fitted)
- 2 x Screws, wall plugs and suspension keyrings
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Excalibur™Commercial utilises high powered ultra violet tubes
to attract flying insects and then electrocutes them on a killing
grid, before collecting them in a removable catch tray.
WARNING
EXCALIBUR™COMMERCIAL IS FOR INDOOR USE ONLY, NOT
SUITABLE FOR USE IN BARNS, STABLES AND SIMILAR LOCATIONS.
Excalibur™Commercial is not to be used by persons with
reduced physical, sensory or mental capabilities, or lack of
experience and training, unless they have been given
instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from Pelsis Ltd or your
supplier.
Not suitable for applications where potentially explosive
environments may exist.
POSITIONING AND GUIDANCE FOR USE
Excalibur™Commercial should ideally be fixed around two
meters above the ground, preferably in the darkest place
within the area to be protected. Do not position the unit close
to windows, skylights or other sources of light, or where it may
be obscured by furniture, doors or other obstacles.
Excalibur™Commercial should ideally be in operation for 24
hours a day, ensuring your premises are kept free of flying
insects. Insects are most attracted to Excalibur™Commercial
units at night when there is no competition from daylight or
other light sources.
GUARANTEE
Excalibur™Commercial has a three year guarantee and if
maintained as recommended in these instructions should
continue to work for many years.* Use of non-approved
consumables may invalidate the guarantee.
*Excludes tubes and starters. Does not cover breakdown due to misuse, incorrect operation
or use in an incorrect application.
SPECIFICATION / REPLACEMENT PARTS
Unit Excalibur Commercial
Voltage 230V ~ 50Hz
Dimensions(mm) 530 x 270 x 155
Coverage 80 Sq. Meters
Weight 4.5 Kg
Light Output 60W
Tubes 2 x TPX15-18
Starter 2 x I154
CATCH TRAY REMOVAL
The catch tray is connected to the power supply of the unit via a hidden switch. By removing the catch tray, the connection
is broken and power is cut to the unit. This ensures safe access to the unit for servicing and cleaning.
NB - WHEN REPLACING THE CATCH TRAY BACK INTO EXCALIBUR™COMMERCIAL, ENSURE IT IS PUSHED FULLY INTO POSITION AND
THAT POWER IS RESTORED TO THE UNIT.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
To ensure the efficiency of Excalibur™Commercial in catching flying insects, the UV tubes should be replaced annually. After
twelve months the phosphor coating that emits the correct wavelength of UV light has burnt away and the UV output is
diminished substantially.
To replace the UV tubes…
1. Remove the catch tray.
2. Remove the killing grid by first pushing it up, then pulling down.
3. Rotate the tube through 90°, freeing it from the tube holder.
(Dispose of the used UV tube in conjunction with local WEEE regulations.)
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT THE UNIT IS
DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tubes. Starters wear out and should be replaced at the same intervals
as the UV tubes.
To replace the starters…
4. Rotate the starter anti-clockwise.
Pull the starter free from the unit.
4
3
1
2
R3 05/16
C2016
Pelsis Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pelsis.com
E [email protected]
WEEE Compliance No. WEE/GF0661QR

Popular Controllers manuals by other brands

Cardinal CLiC WD-02.1.4 installation manual

Cardinal

Cardinal CLiC WD-02.1.4 installation manual

Cooper CEAG GHG 635 GHG 635 operating instructions

Cooper

Cooper CEAG GHG 635 GHG 635 operating instructions

Honeywell HJK7000 UltraKey Plus Technical note

Honeywell

Honeywell HJK7000 UltraKey Plus Technical note

Zeck Audio FOCUS CON2ST Service manual

Zeck Audio

Zeck Audio FOCUS CON2ST Service manual

Mitsubishi Electric MELSEC-QS Series Safety Application Guide

Mitsubishi Electric

Mitsubishi Electric MELSEC-QS Series Safety Application Guide

Datakom D-300 MK2 user manual

Datakom

Datakom D-300 MK2 user manual

Danfoss EKE 1A installation guide

Danfoss

Danfoss EKE 1A installation guide

BN Thermic RD16 instructions

BN Thermic

BN Thermic RD16 instructions

Koganei ZL1 Series manual

Koganei

Koganei ZL1 Series manual

Servomech ILA 15 A Installation, operation and maintenance manual

Servomech

Servomech ILA 15 A Installation, operation and maintenance manual

Hardi HC 9600 Operator's manual

Hardi

Hardi HC 9600 Operator's manual

KISS FLTCTRL Flyduino KISS Flight Controller V2 manual

KISS FLTCTRL

KISS FLTCTRL Flyduino KISS Flight Controller V2 manual

Mecc Alte DER1 Technical guide

Mecc Alte

Mecc Alte DER1 Technical guide

AMX AXLINK WIRING CONSIDERATIONS instruction manual

AMX

AMX AXLINK WIRING CONSIDERATIONS instruction manual

Trane Technologies Symbio 800 Integration guide

Trane Technologies

Trane Technologies Symbio 800 Integration guide

MSTRONIC SOL20A12-56D-BT user manual

MSTRONIC

MSTRONIC SOL20A12-56D-BT user manual

Lindab UltraLink FTCU technical information

Lindab

Lindab UltraLink FTCU technical information

YASKAWA PROFINET V1000 installation manual

YASKAWA

YASKAWA PROFINET V1000 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.