manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Penman Collection
  6. •
  7. Stove
  8. •
  9. Penman Collection 100M User manual

Penman Collection 100M User manual













































INSTALLATIONANDOPERATINGINSTRUCTIONS
STOVESMUSTBEFITTEDBYAPPROVED,QUALIFIEDAND
COMPETENTINSTALLERS

PLEASELEAVETHISBOOKLETWITHTHEHOUSEHOLDER
PenmanStovesoperateatveryhightemperatures.Allpersons
includingchildrenandtheinfirmshouldbewarnedofthisandnot
allowedtotouchanysurfaceswhilstinuse.Theoperatormustuse
thegloveprovided.

www.penmancollection.com
HERITAGE/MODEMODELS:
100M,100W,200M&200W
APPROVED‐CONFORMINGTOEN13240:2001and
EN13240A2:2004
17JUL14_HERMOD_V3


Thefollowingisalistofstoveaccessoriesyourretailerwillbeabletosupply:

•Penmanmatchinggraphitehightemperaturepaint
•StoveGlassCleaner
•SpareRope
•RopeSealAdhesive
•CODetector
•PenmanStoveFan
•PenmanStoveThermometer
•WoodMoistureMeter
•SpareGloves
•PermanentVentilators
•Purpose‐builtAshVacuumCleaner
•PenmanAshCarrier
•PenmanFireScreens
•PenmanCompanionSets
•PenmanLogBaskets
•PenmanSootBox




HETASLTDAPPROVAL

ThesestoveshavebeenapprovedbyHETASLtdasintermittentoperating
appliancesforburningwoodlogsandapprovedsmokelessfuels.












17JUL14_HERMOD_V3

Contents
PAGE
YOURSTOVECONTROLS,ITSOUTPUTANDEFFICIENCY1
LIFETIMEGUARANTEE2
INSTALLATION,OPERATIONANDMAINTENANCE3
SAFETYNOTESANDTROUBLESHOOTING21
COMPONENTDRAWINGANDSPARESLIST24

YourStoveControls,OutputandEfficiency
Heritage100MwithLatticeshown


SecondaryAirControl


PrimaryAirControl


RiddlingMechanism

FUEL
ANTHRACITE
EFFICIENCY
WOOD
EFFICIENCY
STOVEWITHOUTWOOD
CLEANBURNKITCLEANBURNWITHOUTWOOD
CLEANBURNKITCLEANBURN
HERITAGE/MODE
100M(5kW)80%77%81%81%
HERITAGE/MODE
100W(5kW)N/AN/A77%77%‐noclean
burnkitrequired
HERITAGE/MODE
200M(8.8kW)81%75%79%79%
HERITAGE/MODE
200W(8.5kW)N/AN/A83%83%
OutputsstatedareunderidealtestconditionscarriedoutatSGSEnvironmentalServicesinThe
Netherlands.Variationsmayoccurduetoinstallation,atmosphericconditionsandfuelquality.

17JUL14_HERMOD_V3

LIFETIMEGUARANTEE

AllPenmanStovesarecoveredbyalifetimeguarantee(validfororiginal
purchasesonly)fromdateofsale.Thisguaranteeexcludesthefollowing
naturallywearingconsumableitems:DoorGlass,Firebricks,RopeSeals,Baffle&
Grate(includingriddlingsystem).Inaddition,thefollowingcriteriamustbe
met.
•Sightofthedataplatethatshouldhavebeenfittedbytheapproved
installer.
•ProofofinstallationbyHETASorotherapprovedbody,orletterfrom
BuildingControlconfirmingthattheinstallationwasinstalledin
accordancewiththeBuildingRegulations
•Proofofpurchasefromanapprovedsupplier
•Proofofannualsweepingofchimney,atwhichtimeaninspectionasto
theconditionofthechimneyshouldbecarriedouttoallowfor
necessarymaintenancetobeperformed.
•Useonlyrecommendedfuels.Seepages15and16forrecommended
fuels.
PercyDoughty&Cowillacceptnoresponsibilityforinstallationswhichhave
beencarriedoutthatarenotinaccordancewiththeBuildingRegulationsorif
theconditionsstatedinthestoveinstructionsarenotadheredto.
Thisguaranteeappliestopartsonlyandexcludeslabourcosts.
InnoeventshallPercyDoughty&Cobeliableforspecial,incidentalor
consequentialdamages,injurytopersons,damagetopropertyoranyother
consequentialloss.









17JUL14_HERMOD_V3

Installation,OperationandMaintenance

IMPORTANT:THISAPPLIANCEMUSTBEINSTALLEDBYACOMPETENTPERSONANDTHE
INSTALLATIONMUSTCOMPLYWITHBS8303–CODEOFPRACTICEFORINSTALLATIONOF
DOMESTICHEATINGANDCOOKINGAPPLIANCESBURNINGSOLIDMINERALFUEL,NATIONAL
BUILDINGREGULATIONS,LOCALBY‐LAWSANDSTANDARDSANDTHEREQUIREMENTSOFTHE
HEALTHANDSAFETYATWORKACT‐INPARTICULAR:

HANDLING–ADEQUATEFACILITIESMUSTBEAVAILABLEFORLOADING,UNLOADINGANDSITE
HANDLING

FIRECEMENT–SOMETYPESARECAUSTICANDSHOULDNOTBEALLOWEDTOCOMEINTO
CONTACTWITHTHESKIN.INCASEOFCONTACTWASHIMMEDIATELYWITHPLENTYOFWATER

ASBESTOS–THESESTOVESCONTAINNOASBESTOS.IFTHEREISAPOSSIBILITYOFDISTURBING
ANYASBESTOSINTHECOURSEOFINSTALLATIONTHENPLEASESEEKTHEGUIDANCEOFA
SPECIALISTANDUSEAPPROPRIATEPROTECTIVEEQUIPMENT.

METALPARTS–WHENINSTALLINGORSERVICINGTHISSTOVECARESHOULDBETAKENTOAVOID
THEPOSSIBILITYOFPERSONALINJURY

UNLESSTHEINSTALLERISQUALIFIEDTOAPPROVEINSTALLATIONTHENAPPROVALMUSTBE
SOUGHTFROMYOURLOCALBUILDINGCONTROLDEPARTMENT.THESUPPLIERSACCEPTNO
RESPONSIBILITYIFTHISADVICEISNOTFOLLOWED.THISAPPLIANCEHASBEENEXTENSIVELY
TESTEDFORSAFETYANDEFFICIENCY,DONOTATTEMPTTOMODIFYIT.ALWAYSUSEGENUINE
REPLACEMENTPARTSASRECOMMENDEDBYYOURSUPPLIER.FAILURETOADHERETOTHIS
ADVICEWILLINVALIDATEYOURGUARANTEE.

TRYTOAVOIDFITTINGANEXTRACTORFANINTHESAMEROOMASTHISSTOVE.IFTHISIS
UNAVOIDABLETHENSEEKSPECIALISTADVICETOENSURETHATTHEINSTALLATIONISTESTED
FORSAFETY.ASUITABLETESTCOMPRISESCHECKINGFORSPILLAGEIFTHEROOMWHERETHE
APPLIANCEISFITTEDISSUBJECTEDTOTHEGREATESTPOSSIBLEDEPRESSURISATION.THIS
MEANSFIRINGTHEAPPLIANCEWITHALLTHEEXTRACTFANSINTHEBUILDINGOPERATINGAT
THEIRMAXIMUMANDWITHALLDOORS,ADJUSTABLEVENTILATORSANDWINDOWSCLOSED.
IFSPILLAGEOCCURSTHENADDITIONALPERMANENTVENTILATIONDIRECTFROMOUTSIDEWILL
BEREQUIRED.ONCETHEADDITIONALVENTILATIONISFITTED,RETESTASNOTEDABOVE,

ITISESSENTIALANDREQUIREDBYBUILDINGREGULATIONSTHATACARBONMONOXIDE(CO)
ALARMISINSTALLEDINTHESAMEROOMASTHISSTOVE.

THISSTOVEMUSTHAVEITSOWNCHIMNEYANDMUSTNOTSHAREACHIMNEYWITHANOTHER
APPLIANCE.

THISSTOVEISFORINTERMITTENTUSEONLYANDSHOULDNOTBESHUTDOWNOVERNIGHT

VENTILATIONMAYBEREQUIREDINTOYOURROOM,PLEASESEEPAGE10.


17JUL14_HERMOD_V3

Installation

Oncetheinstallationiscomplete,theinstallermustadvisethehouseholderon
thecorrectuseofthestoveandwarnthemtouseonlytherecommendedfuels
listedinthisdocument.Theinstallermustalsoadvisethehouseholderonthe
actionstobetakenshouldsmokeorfumesbeemittedfromthestove.

YourPenmanstovemustnotshareachimneywithanyotherappliance

Wherethechimneyisbelievedtohavepreviouslyservedanopenfire
installationitispossiblethatthehigherfluegastemperaturefromaclosed
appliancemayloosendepositsthatwerepreviouslyfirmlyadhered,withthe
consequentriskofflueblockage.Itisthereforerecommendedthatthechimney
besweptasecondtimewithinamonthofregularuseafterinstallation.

Checkthechimneyisingoodcondition,dry,freefromcracks,leaksand
obstructions.Thediameteroftheflueshouldnotbelessthan150mmandnot
morethat230mm.Ifanyoftheserequirementsarenotmet,thechimney
shouldbelinedbyasuitablemethod.

InthecaseoftheHeritage/Mode100stovesburningascleanburnappliances
(cleanburnkitfitted),a125mmfluelinermaybeusedinaccordancewiththe
BuildingRegulations.Allotherstovesmusthaveaminimum150mmdiameter
liner.Thechimneyandconnectingfluepipeshouldnotnarrowtolessthanthe
sizeoftheoutletsocket(collar)ofthestoveatanypoint.

Thechimneyheightandthepositionofthechimneyterminalmustconformto
BuildingRegulationsandthelatesteditionofBSEN15287‐1:2007,Design,
InstallationandCommissioningofChimneysshouldbefollowed.

Afluedraughtofminimum12Pascalsisrequiredforsatisfactoryappliance
performance.Thefluedraughtshouldbecheckedunderfireathighoutputand
ifitexceeds25Pa,adraughtstabilisermayberequiredsothattherateof
burningcanbecontrolled,andtopreventpossibleover‐firing.

Ifyouhaveanydoubtsaboutthesuitabilityofyourchimney,consultyourlocal
dealer/stockist.Theywillalsobeabletoprovideadviceaboutthepossibleneed
foraspecialistcowl.

17JUL14_HERMOD_V3

Thechimneymustbesweptbeforeconnectiontothestoveandsweptevery
twelvemonthsthereafter.Itisrecommendedthatyourchimneyissweptevery
sixmonths.

Anexistingfireplaceopeningcanbemodifiedtoaccommodatethestove.The
followingpagesidentifysometypicalinstallationscenariosandprovidesthe
necessaryspecificinstallationinformationforyournewstove.Alwaysconsult
yourstovesupplierforadetailedsurveyofyourparticularcircumstances.
Tomakeiteasiertohandlethestoveoninstallation,removethebaffleplates,
bricksanddoor.Placeinasecureplacetoavoiddamage.Refitafter
installation.

Uponcompletionofinstallation,theapplianceshouldbecheckedunderfirefor
soundnessofjointsandseals,andalsothatallsmokeandfumesaretakenfrom
theappliance,upthechimneyandemittedsafely.

TypicalInstallationforInglenookFireplaces–topflue

Inglenookfireplacescanhaveverylargeborechimneys.Checkwithyour
installer–youarelikelytorequireastainlesssteelflexiblelinerforsolidfuelif
yourchimneyislargerthan230mmx230mm.Aclosureplatewithaccessfor
cleaningmayalsoberequiredtogetherwithashortlengthoffluepipeofthe
samediameterasthestovefluecollar.


Closureorregisterplate













Mode200Mshown
17JUL14_HERMOD_V3

TypicalInstallationforInglenookFireplaces–rearflue–SideView




Heritage200Mshown







17JUL14_HERMOD_V3

TypicalRearFlueInstallationwithcleanoutsootdoor

Ideally,theoldfireplaceshouldbefilledinsothatthereisasmoothstreamlined
entryintotheflue.

Thelengthofthehorizontalrunofthefluepipemustnotexceedtheflueoutlet
diameteronthestove.

Itisessentialthatallconnectionsbetweenthestoveandchimneyflueare
sealedandmadeairtight.

BothchimneyandfluepipemustbeaccessibleforcleaningandifALLpartsof
thechimneycannotbereachedthroughthestove,asootdoormustbefittedto
enablethistobedone.


SOOT
DOOR
Heritage100Mshown





17JUL14_HERMOD_V3

TypicalInstallationIntoIn‐filledMasonryFireplaces


Heritage200Mshown








17JUL14_HERMOD_V3

SpecificInstallationInformation

Legs–ApplicabletoHeritage/Mode100Wand200Wversionsonly

Removethelegsfrominsidethestoveandremovethethroatplate,baffleand
sideandbackbricks.Carefullylaythestoveonitsbackandusingthescrews
providedfitthelegsinplace.Carefullysetthestoveuprightandreplacethe
internalcomponents.

ThefollowinginformationappliestoallvariantsoftheHeritage/Mode100M,
Heritage/Mode100w,Heritage/Mode200M,Heritage/Mode200wstoves.

Clearances

Ifthestovesaretobeinstalledadjacentmaterialsthatcancatchfirelikewood
thenthefollowingclearancesmustbeadheredto:

STOVEBACK(mm)SIDES(mm)TOP(mm)
Heritage/Mode100M250300250
Heritage/Mode100W250300250
Heritage/Mode200M450350250
Heritage/Mode200W500400275

Thestovecanberecessedintoasuitablysizedfireplacebuiltfromnon‐
combustiblematerials,butapermanentfreeairgapofatleast100mmshould
beleftaroundthesidesandtoptoobtainmaximumheatoutputandforaccess
totherearofthestove.

Itispossibletofitthestovewithlessclearancearoundit–downto50mm,but
thenon‐combustiblematerialarounditmustbeatleast150mmthick.Thisis
normallyachievedwheninstallingintoastandardbrick‐builtchimneybreast
withdoublethicknesswallstotherearandsidesofthebuilder’sopening.Take
carethatthewallfinishissuitabletowithstandtemperaturesofupto200oC.

Hearths

AlltheHeritage/Modestovesaresuitablefor12mmthicklightdutyhearths.It
isessentialtoensurethattheinsulatingbricksonthebottomofthestoveare
maintainedandreplacedifthereissignificantdamagetothem.Allowanapron
ofatleast225mmatthefrontofthestoveand150mmoneitherside.Care
17JUL14_HERMOD_V3

shouldbetakentolevelthestoveandsecurethehearth.Ifexistingfloorsdonot
haveadequateloadbearingcapacitythensuitablemodificationsmustbe
adopted.Allotherstandardthicknesshearthsaresuitabletoo.

Whenthestoveisinthedesiredposition,fixthebracketsprovidedtotheback
feetandlevelthestoveusingthelevellingscrews,thenmarkthehearththrough
theholes,removethestove,anddrillandplugthehearthforsecuringthestove.
VentilationIntoaRoomForCombustionAirisanEssentialRequirement.

Anyaperturesprovidedforthispurposemustnotberestrictedorblocked

FluesWithoutaFlueDraftStabiliser

WheninstallingtheHeritage/Mode100stoveswithoutafluedraftstabiliser
intohousesbuiltbefore2008,noadditionalpermanentventilationwillbe
required.Housesbuiltafterthisdatewillrequireadditionalmeansof
permanentventilationdirecttooutsideofatleast2750mm2.PenmanVents
canbeusedforthis.

WheninstallingtheHeritage/Mode200stoveswithoutafluedraftstabiliser
intohousesbuiltbefore2008atleast2200mm2additionalmeansofpermanent
ventilationdirecttooutsideisrequired.Forhousesbuiltafter2008atleast
4950mm2additionalmeansofpermanentventilationdirecttooutsideis
required.PenmanVentscanbeusedforthis.

FluesWithaFlueDraftStabiliser

WheninstallingtheHeritage/Mode100stoveswithafluedraftstabiliserinto
housesbuiltbefore2008,atleast1500mm2additionalmeansofpermanent
ventilationdirecttooutsideisrequired.Housesbuiltafterthisdatewillrequire
additionalmeansofpermanentventilationdirecttooutsideofatleast4250
mm2.PenmanVentscanbeusedforthis.

WheninstallingtheHeritage/Mode200stoveswithafluedraftstabiliserinto
housesbuiltbefore2008atleast4900mm2additionalmeansofpermanent
ventilationdirecttooutsideisrequired.Forhousesbuiltafter2008atleast
7650mm2additionalmeansofpermanentventilationdirecttooutsideis
required.PenmanVentscanbeusedforthis.

17JUL14_HERMOD_V3

LatticeInstallation

Removetheglasspanelasshownonpage20andlocatethelatticeinplacefrom
thebackofthedoor.Ensurethatthesteeltabsarelocatedagainstthewindow
frameandtheheatresistantpadsareinplaceoverthesteeltabstoprotectthe
glasspanel.Replacetheglasspanelasdescribedonpage20.

ToporRearFlue

Removethecollarandaccessorypackfromthestove.Thestovewillarrivewith
theblankingplatefittedtotherear.Thiscanberemovedifrequiredallowing
thecollartobefittedforrearflueinstallations.Thecircularcutoutintherear
heatshieldmustberemovedtoenablethisstyleofconnection–seeimage
below.

Removethepanelfromthestove
byunscrewingthefourscrewsand
thenremovethecircularcutout
forrearflueinstallations.Replace
therearheatshield.

Remembertofittheblankingplate
totheunusedfluepositionifithas
beenremoved.









Heritage200Mshown





17JUL14_HERMOD_V3

Dimensions

100M 100W 200M 200WDIM
[mm]HERITAGEEMODEE HERITAGEE MODEEHERITAGEE MODEE HERITAGEEMODEE
A573568573568630630630630
B474451474451578551578551
C225213225213275265275265
D460468460468512515512515
E376390376390422419422419
F117117117117125130125130
G125125125125150150150150
H430427430427530530530530
I439434439434485480485480
J100100100100115115115115
K613608613608683683683683


Dimensionsmayvaryslightly,themanufacturersreservetherighttoadjust
themwithoutnotice.






17JUL14_HERMOD_V3

Operation

ALWAYSOPENTHESTOVEDOORSLOWLYANDALWAYSUSETHEGLOVE

PrimaryAir

Primaryairiscontrolledviatherotatingventinthebottomofthedoor.This
providesanairdraughttothebedofthefire.Rotateanti‐clockwisetoopenand
clockwisetoclose.Openthiswhenyoustartafireandtomanageanthracite
fires.Itshouldbeclosedwhenawoodfireisestablishedforthebestefficiency.

SecondaryAir

Secondaryairiscontrolledviatheslidingventabovethedoor,itisthis‘airwash’
thatkeepsacleananduninterruptedviewofthefire,alsoaidinggood
secondarycombustionoffuelandreducingemissionsintothechimneyand
environment.Slidetotherighttoopenandtothelefttoclose.Usethisto
controlwoodfires.Itshouldbeclosedwhenburninganthraciteforthebest
efficiencyafterthefireisestablished.

TertiaryAir–Heritage/Mode100W&200WONLY

TheHeritage/Mode100WandHeritage/Mode200Wstovesarefittedwitha
tertiary(third)airinletsystem.Airisbledintothestovefromtherearpanel.Its
functionistoigniteunburnedgassesassistingwithacleanburn.Itisadvisable
tocleartheseholesfromtimetotimewithabrush,especiallywhenthestoveis
beingservicedorafterlongperiodsofburning–particularlyif“dirty”fuelssuch
asdampwoodorbituminouscoalareused.ONLYCARRYOUTTHISANDALL
SERVICINGPROCEDURESWHENTHESTOVEISCOLD.Thistertiaryairsupplyis
permanentlyopenandallowsasmallamountofairintothestove.Operation
withaircontrolsopencancauseexcesssmoke.Thesestovesmustnotbe
operatedwithaircontrolsleftopenexceptasdirectedintheseinstructions.

LightingtheStove

Itisessentialthatyouhavethreeorfoursmallfiresbeforeyouoperatethe
stovetoitsmaximumheatoutput.Thisistoallowthepainttocureandto
“temper”yourcastironstove.Werecommendthis‘running‐in’procedureafter
longshutdownstopreservethelifeofstove.Duringthecuringofthepaint,you
17JUL14_HERMOD_V3

maynoticeanunpleasantsmell.Itisnottoxic,butforyourcomfortwewould
suggestthatduringthisperiodyouleavedoorsandwindowsopen.

First,loadthefirewithstartingfueli.e.paper,drykindlingtimber(aboutthe
thicknessofyourthumb)and/orfirelightersinthemodechosen,eitherwoodor
solidmineralfuelproducts.Itisnormaltoseesmokecomefromtheopenstove
dooratthisstage.

Lightthefireatbaseleavingallaircontrolsopen.Allowthefueltoreacha
steadyglowandbuildupthefiregradually.Onceyouhaveagoodfire
establishedacrossthefirebed,furtherfuelcanbeaddedasrequired.

Whenyourfireiswellestablishedyoucanstarttorestricttheprimaryairintake.
Ifyouareburningonlywood,theprimaryaircontrolcanbefullyclosed.Ifyou
areburningsolidmineralfuelyouwillrequiresomeprimaryair.Yourstoveis
burningwithmaximumefficiencywhenabrightfireisachievedusingminimum
airinletandthePenmanStoveThermometerregisterswithinthe“BestBurn”
range.

WoodBurning

Woodburnsbestonabedofashanditisthereforeonlynecessarytoremove
surplusashfromthegrateoccasionally.Burnonlykilndriedorwell‐seasoned
wood,whichshouldhavebeencut,splitandstackedundercoverforatleast36
months,withfreeairmovementaroundthesidesofthestacktoenableittodry
out.Burningwetorunseasonedwoodwillcreatetardepositsinthestoveand
chimneyandwillreduceheatoutput.Tardeposits,ifallowedtobuildup,area
majorcauseofchimneyfires.Thistaralsoisthemaincauseofblackenedstove
windows.APenmanwoodmoisturemeterisahandydevicetohave.

OnceestablishedandforthebestresultsfromyourHeritage/Mode100Wor
100Mstove,loadabout1.5to2kgofgoodqualitydrywoodperhourwiththe
primaryaircontrolfullyclosedandthesecondaryaircontrolabouthalftotwo
thirdsclosed.Logscanbeupto300mmor12”long.Donotoverload.

OnceestablishedandforthebestresultsfromyourHeritage/Mode200Wor
200Mstove,loadabout2to3kgofgoodqualitydrywoodperhourwiththe
primaryaircontrolfullyclosedandthesecondaryaircontrolabouthalftotwo
thirdsclosed.Logscanbeupto400mmor15”long.Donotoverload.

17JUL14_HERMOD_V3

Ofcourse,bestburningdependsonthequalityofwood,draftandstove
settings,sopleasedoexperimenttofindyourownbestsettingsandthebest
positiononyourStoveThermometer.

OtherSolidFuelBurning

Alwayscleanouttheashpanbeforerefuellinganddonotlettheashbuildupto
theundersideofthegratebars–thiswillseverelyreducethelifeofthegrate
andpreventefficientburning.Solidfuelproducesash,whichifallowedtobuild
up,willstifletheairflowthroughthegrateandeventuallycausethefiretodie.
Caution–onlyemptytheashpanwhenthestoveiscool.

Withsomesolidfuelsaresidueofburntfuelorclinkerwillaccumulateonthe
grate,allowthefiretogooutperiodicallytoremovethis.

OnceestablishedandforthebestresultsfromyourHeritage/Mode100M
stove,loadabout1kgofanthraciteorequivalentperhourwiththeprimaryair
controlabouthalftothreequartersopenandthesecondaryaircontrolfully
closed.Donotoverload.

OnceestablishedandforthebestresultsfromyourHeritage/Mode200M
stove,loadabout1¼kgofanthraciteorequivalentperhourwiththeprimary
aircontrolabouthalftothreequartersopenandthesecondaryaircontrolfully
closed.Donotoverload.

Ofcoursebestburningdependsonthetypeoffuelbeingburnt,draftandstove
settings,sopleasedoexperimenttofindyourownbestsettings.

De‐Ashing

Duringstoveuse,whilstburninganthraciteoramixofwoodandanthracite,
fromtimetotimetheriddlermustbeusedtoremoveashensuringairflow
throughthefirebedandallowingthefiretoburnoverthewholegrate.The
riddlinghandleisnexttotherightlegofthestove.Usingthegloveprovided,
movethisgentlybackwardsandforwardsasnecessaryuntilthefireshowssigns
ofmoreairreachingun‐burntfuel.Donotforcethismechanismifitbecomes
veryhardtomove–theremaybesomedebriscaughtinthegrate–ifthisisthe
case,carefullyopenthestoveandusingapokerinaglovedhand,gentlyagitate
thefuelbed.

17JUL14_HERMOD_V3

RecommendedFuels

PleasenotethatHETASLtdApplianceApprovalonlycoverstheuseofwoodlogs
andapprovedsmokelessfuelsonthisappliance.HETASLtdApprovaldoesnot
covertheuseofotherfuelseitheraloneormixedwiththerecommendedfuels
listedabove,nordoesitcoverinstructionsfortheuseofotherfuels

Wood‐Onlykiln‐driedorwell‐seasonedwoodwithamoisturecontentreading
oflessthan18%isrecommended.APenmanmoisturemeterisahandydevice
tohaveandisavailablefromyoursupplier.Asarule‐of‐thumb,woodseasonsat
about1”(25mm)peryear,soalogsplitsuchthatalongitslengthnodimension
isgreaterthan3”(75mm),itwouldtakeabout3yearstodry.Adrylogwill
produceuptofourandahalftimesmoreheatoutputthanafreshlycutlog.
Wetlogstakeheattodry.
OtherSolidFuel–“Authorised”fuelsincludeanthracitelargenuts,briquettes
smokelessfuel,ie.Ancit,Phurnacite,Taybrite,HomefireOvalssuitableforclosed
appliances.

UnauthorisedFuels

DONOTburnWildfire,Housecoal,householdcoal,petroleumcokesor
householdwaste.Theuseofunauthorisedfuelswillinvalidateyour
guarantee.IfindoubtconsultyourmerchantortheSolidFuelAssociation.
Pleasenotethatwhenrefuellingwithsolidfuel,donotpilefuelhigherthan30
degreesfromthefrontbarrearwards–over‐fuellingcancauseexcesssmoke
andproducetemperaturesbeyondthedesignedratingoftheappliancecausing
damagetointernalparts.
Thisapplianceisdesignedtobeoperatedwiththedoorclosed,exceptfor
refuelling.Notonlyisitunsafetooperatewiththedooropenbuttheappliance
efficiencywillbesignificantlyreducedandexcesssmokecanoccur.

Thestoveisdesignedtooperateintermittentlyandmustnotbeusedasan
overnightburner.



17JUL14_HERMOD_V3

CleanBurn‐TheCleanAirAct1993andSmokeControlAreas

Localauthoritiesmaydeclarethewholeorpartoftheirzonetobeasmoke
controlarea.Itisanoffencetoemitsmokefromachimneyofabuildingif
locatedinadesignatedsmokecontrolarea.Itisalsoanoffencetoacquirean
"unauthorisedfuel"forusewithinasmokecontrolareaunlessitisusedinan
"exempt"appliance.
TheSecretaryofStateforEnvironment,FoodandRuralAffairshaspowersto
authorisesmokelessfuelsorexemptappliancesforuseinsmokecontrolareasin
England.InScotlandandWalesthispowerrestswithMinistersinthedevolved
administrationsforthosecountries.Separatelegislation,theCleanAir
(NorthernIreland)Order1981,appliesinNorthernIreland.Thereforeitisa
requirementthatfuelsburntorobtainedforuseinsmokecontrolareashave
been"authorised"andthatappliancesusedtoburnsolidfuelinthoseareas
(otherthan"authorised"fuels)havebeenexemptedforeachareaof
administration.FurtherinformationontherequirementsoftheCleanAirAct
canbefoundat:http://smokecontrol.defra.gov.uk/

Yourstove,aslisted,belowhasbeenrecommendedassuitableforuseinsmoke
controlareaswhenburningdrywoodandthe“authorised”fuelslistedbelow.It
issuppliedwithasmallkitinablisterpackwhichmustbefittedifyouintendto
burndrywoodinasmokecontrolarea.Pleasenotethetablebelowandfollow
theinstructionsifyouintendtooperateyourstoveinsmokecontrolzone.
STOVEDRY
WOOD
SMOKEFREE
SOLIDFUEL
FITKITIFWOOD
ISTOBEBURNT
Heritage/Mode100M99FITKIT
Heritage/Mode100W9N/ANOTREQUIRED
Heritage/Mode200M99FITKIT
Heritage/Mode200W9N/AFITKIT

The“authorised”solidfuelsyouarepermittedtoburninasmokecontrolzone
include:anthracite(thisisnaturallyoccurringsmokelessfuelandisthetestfuel
normallyusedandrecommended),Ecoal50,Homefire,Homefireovals,
Phurnacite,TaybriteandMultiheat





17JUL14_HERMOD_V3

CleanBurnKitInstallationInstructionsFORINSTALLERONLY
1. Openthestovedoor.
2. Slidethesecondaryaircontrol
completelytotheright.
3. Removethesmallscrewunderthe
topofthestovepositionedtothe
leftofthesecondaryaircontrol
4. Fitthescrewfromtheblisterpack
andensureitisscrewedintightly.

Thiskitwillpreventthesecondaryairfromfullyclosing,whilststillproviding
goodcontrol.Itreducesthemaximumefficiencyoftheanthraciteburnbyafew
percentagepoints–seethechartatthebeginningoftheseinstructions.
Someadditionalkeypointsrelatingtoburningfuelonthisappliancewhenused
intheCleanBurnmodefollow:

RefuellingOntoaLowFireBed

Ifthefirebedisnotsufficienttolightanewfuelcharge,excessivesmoke
emissioncanoccur.Refuellingmustbecarriedoutontoabedofglowingembers
andashsuchthatthenewfuelignitesinareasonableperiod.Iftherearetoo
fewembersinthefirebed,addkindlingtopreventexcessivesmoke.

GeneralMaintenance

Onlyevercarryoutmaintenancewhenthestoveiscold.

Forcomponentidentificationrefertothediagramlaterintheinstructions.

Thefollowingelementsofmaintenancemaybecarriedoutbythehouseholder.
Anystructuralrepairs,e.g.panel,collaror
stovepipereplacementmustbecarriedout
byasuitablyqualifiedinstaller.

ThroatPlateRemovalandReplacement

Theseshouldberemovedatleastoncea
monthtopreventabuild‐upofsootorfly
ashwhichcouldleadtoblockedflueways
anddangerousfumeemission.
17JUL14_HERMOD_V3


This manual suits for next models

3

Other Penman Collection Stove manuals

Penman Collection Helios 8 User manual

Penman Collection

Penman Collection Helios 8 User manual

Penman Collection VEGA C7 User manual

Penman Collection

Penman Collection VEGA C7 User manual

Penman Collection VEGA 100 User manual

Penman Collection

Penman Collection VEGA 100 User manual

Popular Stove manuals by other brands

Regency F33 Owners & installation manual

Regency

Regency F33 Owners & installation manual

Blaze King 9603 Owner's installation and operation manual

Blaze King

Blaze King 9603 Owner's installation and operation manual

Stanley Tara Mk3 Installation and operation instructions

Stanley

Stanley Tara Mk3 Installation and operation instructions

AMI 5E Operating & installation instructions

AMI

AMI 5E Operating & installation instructions

Monessen Hearth DSSNVMB Installation and operating instructions

Monessen Hearth

Monessen Hearth DSSNVMB Installation and operating instructions

Palazzetti ECOFIRE MARTINA LUX IDRO Series PRODUCT TECHNICAL DETAILS

Palazzetti

Palazzetti ECOFIRE MARTINA LUX IDRO Series PRODUCT TECHNICAL DETAILS

Quadra-Fire SAPH-MBK-IPI owner's manual

Quadra-Fire

Quadra-Fire SAPH-MBK-IPI owner's manual

Aarrow ECB5PLUS SC user guide

Aarrow

Aarrow ECB5PLUS SC user guide

Teba therm T-25 Installation and manual

Teba therm

Teba therm T-25 Installation and manual

IKI KIVI-IKI SL Instructions for installation and use

IKI

IKI KIVI-IKI SL Instructions for installation and use

Hunter Stoves Herald 8 CE V.11 Installation and operating instructions

Hunter Stoves

Hunter Stoves Herald 8 CE V.11 Installation and operating instructions

Drooff Andalo 3 L General Instructions for Use

Drooff

Drooff Andalo 3 L General Instructions for Use

Charnwood Country 8B Operating and installation instructions

Charnwood

Charnwood Country 8B Operating and installation instructions

ACR STOVES MV2CL Technical manual

ACR STOVES

ACR STOVES MV2CL Technical manual

Heat Design FW5C Installation and operating instructions

Heat Design

Heat Design FW5C Installation and operating instructions

Campingaz CAMP'BISTRO XL STOPGAZ Instructions for use

Campingaz

Campingaz CAMP'BISTRO XL STOPGAZ Instructions for use

ROE DEER DERRY A000003 instruction manual

ROE DEER

ROE DEER DERRY A000003 instruction manual

Wamsler W3-90 Instructions for installation and use

Wamsler

Wamsler W3-90 Instructions for installation and use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.