Perin WeighMaster 800 Instruction Manual

WEIGHT INDICATOR
Model 800
USER’S HANDBOOK
english
PERIN
WeighMaster
Perin WeighMaster s.r.l.
via Paolo Borsellino, 15
26845 Codogno (LO) - ITALY
Tel. +39 0377 437033 - Fax 437046
www.farmscale.com
email: [email protected]

INDEX
page
Safety regulations for system installation and maintenance................................3
Maintenance.............................................................................................................3
Disposal of the device..............................................................................................3
Description of the device........................................................................................4
onnections............................................................................................................4
Battery test..................................................................................................................4
Function of keys.......................................................................................................5
Messages and icons on display................................................................................5
Use as simple weight indicator............................................................................6
Zeroing (tare)...................................................................................................6
Partial weighings..................................................................................................6
Use with quick alarm.....................................................................................6
Selection of functions...........................................................................................6
Programming recipes.... ..........................................................................................7
Programming loading in total values....................................................................7
Loading ration N° 1 (total values)........................................................................8
Programming per number of animals...................................................................9
Loading ration N° 2 (number of animals)............................................................11
Programming unloading groups........................................................................11
Unloading ration N° 3 (groups)..........................................................................12
Extra functions................................................................................................13
HOLD function (weight freeze)....................................................................13
Programmed weight restore function................................................................13
Selection of the component............................................................................13
Selection automatic/manual passage...............................................................13
Ingredients Reproportion....................................................................................13
Storage function......................................................................................................14
Troubles and solutions.............................................................................................14
System representation.............................................................................................15
Technical details...................................................................................................15
onfiguration starting parameters...........................................................................16
Warranty..........................................................................................................17
Accessories on demand...........................................................................................18
Declaration of onformity...................................................................................19

The producer
PERIN WEIGHMASTER SRL
Viale A. Moro 7
26845 odogno (LO)
declares that the below-mentioned equipment is in accordance with the essential
requirements of the applicable regulations:
1 Electromagnetic ompatibility Directive EM 2004/108/ E (ex 89/336/ EE)
and Legislative Decree N. 194/2007.
Applied harmonized law:
- EI EN 61326
odogno, 02 February 2015
The technical head
Fabio Perin
Denomination Weighing System
800Model
CE Declaration of conformity

MAINTENANCE
FarmScale mod. 800 does not require any regular maintenance, however it is necessary to
check the conditions of the weighing system periodically.
1) Make sure that there are no disturbing elements between the supporting chassis and the
platform or the container, the basin, the feeder, etc.
2) Make sure that the load cells are not damaged (no cracks nor dents), not rusty, not corroded
by acids.
3) Make sure that there is enough space between the chassis and the components of the
weighing system; lubricate if necessary.
4) Make a test: load a weight on each corner, the displayed amount must be nearly the same.
5) Make sure that the connectors are tight and that the cables are undamaged (no cuts nor
abrasions). Remember that, where food is stored or handled, small rodents often gnaw
cables which are situated in hidden or scarcely reachable places.
6) heck that there is no oxidation nor humidity on the connecting points.
7) Do not install the device near heat sources (radiators/oil tanks). Do not fix it on surfaces
with strong vibrations.
DISPOSAL OF THE DEVICE
SAFETY REGULATIONS FOR SYSTEM INSTALLATION AND MAINTENANCE
- Install only when power supply is disconnected.
- Do not install the device near heat sources or near strong magnetic fields.
- Disconnect the power supply cable from the weight indicator when you need to recharge the
battery of the means of transport.
- Immediately disconnect the power supply cable if the cables or the connectors are stripped
or damaged, if the system has particular problems or if there is liquid/humidity in the device.
- The tension should stay between 12V and 14V to avoid damaging the other parts of the
system. The device works correctly with tensions between 10V and 24V.
- Before cleaning the machine with high pressure waterjets, disconnect the cables, remove the
weight indicator from the machine and protect the connectors of the cables from water seepage.
Pay attention that the load cells, the junction box, the alarm and other accessories are not
exposed to direct waterjets.
If the device needs to be cleaned, use soft and lightly humid cloths.
Do not use sprays, solvents, abrasives, sharp or cutting objects which could damage the case.
- Do not open the device, to avoid losing the warranty right. For maintenance/reparation, address
to our company or to technical authorized staff.
- Before doing any welding on the machine, disconnect the cables.
To prevent welding current from passing through load cells, it is necessary to shortcircuit the
body of the load cells with a cable with adequate section and the earth of the welder must be
connected near the point where you weld.
This symbol, present on the product or on the handbook, indicates that the product
cannot be thrown together with household garbage (European Directive 2012/19/EU).
The final user has to dispose of the device at a gathering place for recycling and
disposal of electrical and electronical devices. The separate refuse collection and
the correct recycling of the devices allow to protect the health of people and
ecosystem. For further information concerning gathering points for devices, contact
the local authority for the disposal of garbage or the distributor where the product
has been purchased.

Indicator mod. 800
4
DESCRIPTION OF THE DEVICE
indicators of recipe
and ingredient n°
6 operative keys
load cells connector
power supply
connector -
alarm output
weight value
and messages
on/off switch
BATTERY TEST
The battery test should be made periodically (entering voltage level to FarmScale mod. 800).
To carry out this test, when you are in total weight mode, keep the key pressed;
"volts" with the voltage value of power supply will be displayed and the alarm will sound
intermittently. Press once again to have the direct weight reading.
function
indicators
starbus
connector for
remote display
(optional)
CONNECTIONS
The device has got three connectors. From left to right: a 5 pin connector for the connection
of the extension cable (LOAD ELLS), an optional 7 pin connector for the connection of
remote displays (STARBUS), a 3 pin connector for the connection of the power supply and
alarm cable (POWER).
Before making connections, make sure that the device and the possible peripherals are off.
Before introducing any connector, make sure it is the right one and then connect it adequately,
otherwise damages to the device could occur.
After having introduced the connector, screw the fixing ring.
To disconnect the cables from the plugs, rotate the upper ring anticlockwise, keeping the
lower ring steady. Pull out the connector. Do not pull the cable directly.
Table of contents