1.Mounting
Usingthescrewsprovided,mounttheMini‐Clikonanysurfacewhereitwillbeexposedto
unobstructedrainfall.Theswitch‐housingportionmustbeupright(aspictured),toensureaproper
function.
Theswivellingbracketcanbemountedwiththedeliveredscrewsonanysurface.Beforebringingthe
unitinanuprightposition,loosenthelocknutsandre‐tightenthem.Whenlookingforasuitable
locationmakesuretheunitisnotmountedinthepathofanysprinklerspray.
Figure1
2.Connectingdiagram
2.1 Ifanextensionoftheconnectingwiresisnecessary,makesurethewirecrosssectionisnot
smallerthan1qmm.
2.2 Dependingontheversion,theMini‐Clikcanoperatewithanormallyclosedoropencontact.
BothwiringfacilitiesaregivenatthecontrollersWaterControl,GreenkeeperandPerrot
Satellite.
2.2.1 ConnectionofMini‐ClikatPerrotControllerswith(preferably)normallyclosedcontact
Usethefollowingterminalconnections:
a.) WaterControl
Attachfirstwireatthefirstterminalofthe
controllerdesignatedas“sensor”.
Attachsecondwireatthesecondterminalofthe
controllerdesignatedas“sensor”.
b.) PerrotSatelliteandGreenkeeper:
Attachfirstwireatterminalno.13ofthecontroller
Attachsecondwireatterminalno.14ofthecontroller

Bedie01e.docRev.03.02.2014Page3/4
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Phone:0049‐7051‐162‐0/Fax:0049‐7051‐162–133
E‐mail:[email protected]/E‐mailTechnicalDepartment:[email protected]
2.2.2ConnectionofMini‐ClikatthePerrotControllerswithanormallyopencontact
a.) WaterControl:
Attachfirstwireatfirstterminaldesignatedas“sensor”
Attachsecondwireatsecondterminaldesignatedas“sensor”
b.) PerrotSatelliteandGreenkeeper:
Attachfirstwireatterminalno.11ofthecontroller
Attachsecondwireatterminal12ofthecontroller
Note: WheninstallingtheGreenkeeperandPerrotSatelliteControllers,therainsensorhasto
beenteredtotheinstallationdataofthecomputerprogramme(seeoperatingmanual
Greenkeeper/PerrotSatellite).
2.2.3ConnectionoftheMini‐Cliktoothercontrollers:
PriortotheconnectionpleasecheckwhethertheMini‐Clikshouldbeinstalledtoanormally
openorclosedterminal
2.3 Weareatyourfulldisposalifanyothermodesofconnectionorapplicationarerequested.
3.AdjustmentsandOperation
3.1 Iftherainfallquantities,presetattheMini‐Clik,exceedtheenteredvalue,
theirrigationcycleisstopped,respectively;thenextscheduledirrigation
cycleisnotstarted.
Followingquantitiescanbeadjusted:
Setvalue1/8 =Precipitationquantity3mm
Setvalue¼ =Precipitationquantity6mm
Setvalue½ =Precipitationquantity13mm
Setvalue¾ =Precipitationquantity19mm
Setvalue1 =Precipitationquantity25mm
3.2 Toadjustittothedesiredshut‐offquantity,twistthecaponthehousingsothatthepinsare
locatedintheproperslots(seefigureno.2).Donotforciblytwistthecapasthismightbreak
thepins.

Bedie01e.docRev.03.02.2014Page4/4
PerrotREGNERBAUCALWGmbHIndustriestraße19‐29/D‐75382Althengstett/Germany
Phone:0049‐7051‐162‐0/Fax:0049‐7051‐162–133
E‐mail:[email protected]/E‐mailTechnicalDepartment:[email protected]
3.3 IftheMini‐Clikisexposedtorainfall,thehygroscopicdiscswillswellupandthusactivatethe
contacttostoporrespectivelypreventfromdecontrollingthenextscheduledirrigationcycle.
TheMini‐Clikwillreactivatethenextprogrammedirrigationcycleafterthediscshavedriedup
byweatherconditions(wind,sunlight,humidity,etc.).Byturningtheventring,theventilation
performancecanbechanged.Thiswillinfluencethedryingspeed:biggestventilation
performance–maximumdryingspeedandviceversa(seefigureno.2.)
Thus,theMini‐Clikoffersthepossibilitytoadjustthedryingspeedofthehygroscopicdiscsto
thesoilconditionsatsite.Experiencewillbestdeterminetheidealventilationsetting.
Referencevalues:forsandypermeabletowatersoils–adjustbiggerventilationperformance.
IftheMini‐Clikisinstalledatanoverlysunnyplace–adjustasmallerventilationperformance.
Figure2
4.Benefits
Mini‐Clikdoesnotcollecttherainfallbutabsorbsitbythehygroscopicdiscs.
Thusthesystemhasthefollowingadvantages:
Measurementisnotfalsifiedbyleaves,boughsoranyotherforeignparticles
Nofrostdamagesbycollectedwater
Decontrolofthenextscheduledirrigationcycleiscontrolledandautomaticallyactivated
Subjecttochangewithoutpriornotice.
Pleasedonothesitatetocontactforanyadditionalinformation.
Table of contents
Popular Accessories manuals by other brands

Bomet
Bomet Gemma S290 owner's manual

Paramount Fitness
Paramount Fitness Ultra UV 004-422-2025-00 Installation & operation manual

DigiDesign
DigiDesign Mbox Getting started guide

SCHUNK
SCHUNK FTN-AXIA Assembly and operating manual

Adeunis RF
Adeunis RF LoRaWAN ARF8170BA-B01 quick start guide

Centronic
Centronic SensorControl SC911 Assembly and operating instructions