•Coating Thickness •Hardness testers •Ultrasonic thickness •Surface Roughness •
Operation:
Press the On/Off button to power the unit on.
The hardness value displayed should read “000” HA(HD). If any other value
is displayed, press the Zero button to clear. To check accuracy, manually
place the indentor of the gage on a calibration block. Slowly press the gage
down until the foot of the gage is flat on the surface for 1 second. At that
time, the reading should be within +/- 2Ha points of the actual value.
Hold Feature:
Follow above procedure and press the H button when taking a test. This will
hold that value until you press H again to return to zero.
Calibrated Test Blocks: (Call 201- 933-6300 to order)
Model No. Description
PHT950-25 7pc Master Test Block Kit (Shore “A”)
PHT975-25 3pc Master Test Block Kit ( Shore “D”)
Features:
•Measuring range: 0-100HSA (0-100 HSD)
•Deviation: <1%H
•Resolution: 0 .5H
•Digital read out
•Auto Hold feature
•Accurate and repetitive deviation = 20~90HSA
HSA<+/-1grade
•Conforms to ASTM D-2240, ISO 7619, DIN
53505 standards
•Uses 1-SR44 Button Cell Battery
•Custom carry case
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com