Page 1.2 DIFFERENTIAL BUS FAULT INSERTION CARD 50-200
pickering
SECTION 1 - TECHNICAL SPECIFICATION
Differential Bus Fault Insertion Switch, 50-200
pickeringtest.com
Specifications
Data Path Specification
Configuration: 4 or 8 pairs of two wire
connections designed for
use on differential serial
interfaces.
Faults Simulated: Open on either wire or
both, short between wires,
short to one of eight fault
connections via four fault
buses.
Differential Line
Impedance:
120 Ω
Voltage Rating:
Current Rating:
Max Hot Switch Power:
100 V*
0.3 A
30 W
Path Resistance: <2.5 Ω
Typical Bandwidth: 50 MHz Differential
Operate Time: 4 ms (typical)†
* For full voltage rating, signal sources must be fully
isolated from mains supply and safety earth.
† Including Mode A restricted usage feature overhead - see
user manual for further information.
Power Requirements
+3.3 V +5 V +12 V -12 V
150 mA 1 A 0 0
Mechanical Characteristics
Single slot short PCI format.
3D models for all versions in a variety of popular file
formats are available on request.
Connectors
Signals via a 78-pin male D-type connector, for pin outs
please refer to the operating manual.
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
PCI Compliance
The 50-200 complies with the PCI Specification 2.0 (issued
Feb 2004).
Signalling Environment: 33 MHz, 32-bit Universal
(+3.3 V or +5 V).
Safety & CE Compliance
All cards are fully CE compliant and meet applicable
EU directives: Low-voltage safety EN61010-1:2010,
EMC Immunity EN61326-1:2013,
Emissions EN55011:2009+A1:2010.
Relay Type
The 50-200 is fitted with high quality electro-mechanical
relays, palladium-ruthenium gold covered contacts. A
spare relay is built onto the circuit board to allow easy
maintenance with minimum downtime.
Fault Bus Specification
Configuration: Four fault buses each with
a changeover relay for
selecting one of two fault
conditions.
Voltage Rating:
Current Rating:
Max Hot Switch Power:
100 V*
2 A
60 W
* For full voltage rating, signal sources must be fully
isolated from mains supply and safety earth.