pickeringtest.com
PXI High Density 2 Amp Multiplexer 40-614B
ISSUE 1.0 FEB 2019
Supported by
eBIRST
eBIRST switching system test tools simplify fault-nding by quickly
testing the system and graphically identifying the faulty relay.
For more information go to: pickeringtest.com/ebirst
• Low Cost Fixed Configuration Alternative to
Versatile Solutions - Simpler to Program &
Improved Isolation Between Banks
• 20 Configurations
• 1, 2, 4, 8 or 16 Multiplexer Banks
• Channel Counts of 4, 8, 16, 32, 64 or 128
• Available With 1, 2, 4, 8, 16 or 32 Poles
• 2A Hot or Cold Switching
• Switch up to 200VDC/140VAC and up to
60W Max Power
• VISA, IVI & Kernel Drivers Supplied for Windows
• Supported by PXI or LXI Chassis
• Supported by
eBIRST
™
• 3 Year Warranty
1
2
4
C1
8
BANK 1
3
5
6
7
1
2
4
C2
8
BANK 2
3
5
6
7
1
2
4
C3
8
BANK 3
3
5
6
7
1
2
4
C15
8
BANK 15
3
5
6
7
1
2
4
C16
8
BANK 16
3
5
6
7
40-614B-001 16-Bank, 8-Channel 1-Pole Multiplexer
The 40-614B High Density 2 Amp Multiplexer module is available in 20
congurations as outlined in the table. They all use high quality electro-
mechanical signal relays allowing each channel to switch current up to
2A and voltage up to 200VDC/140VAC.
The module is suitable for signal routing in ATE and data acquisition
systems. Connections are made via a front panel 160-pin DIN 41612
connector.Larger multiplexers may be constructed by daisy chaining the
common signals from multiple modules.
The 40-614B can be operated as a conventional multiplexer with break-
before-make action when a new channel is selected. Alternatively, 2, 4,
8, 16 and 32-pole variants of the multiplexer can be supplied that allow
multiple channels to be simultaneously selected.
Note: The multiple channel selection option is not available for 1-pole
versions of the 40-614B multiplexer.
The 40-614B channel selection congurations have been revised from
the 40-614. The 40-614B module defaults to single channel selection with
multiple channel selection variants dened by use of a sufx.
40-614B 2 Amp Multiplexer Range:
16 Banks, 8 Channels, 1-Pole.
16 Banks, 4 Channels, 2-Pole.
8 Banks, 16 Channels, 1-Pole.
8 Banks, 8 Channels, 2-Pole.
8 Banks, 4 Channels, 4-Pole.
4 Banks, 32 Channels, 1-Pole.
4 Banks, 16 Channels, 2-Pole.
4 Banks, 8 Channels, 4-Pole.
4 Banks, 4 Channels, 8-Pole.
2 Banks, 64 Channels, 1-Pole.
2 Banks, 32 Channels, 2-Pole.
2 Banks, 16 Channels, 4-Pole.
2 Banks, 8 Channels, 8-Pole.
2 Banks, 4 Channels, 16-Pole.
1 Bank, 128 Channels, 1-Pole.
1 Bank, 64 Channels, 2-Pole.
1 Bank, 32 Channels, 4-Pole.
1 Bank, 16 Channels, 8-Pole.
1 Bank, 8 Channels, 16-Pole.
1 Bank, 4 Channels, 32-Pole.