ASZ
(3410p, 3410r, 3420p, 3420r)
Operation manual
1.2 See Table 1 for output specifications.
Table 1 - Output parameters
Number of measuring channels
- 3410p, 3420p - voltage (Uout)
- 3410r, 3420r - current (Iout)
1 ... 5 V
Tripping threshold (configurable)*
Operation mode (outputs switching) *
hysteresis / window /
pulse
Switching accuracy**:
- 3410p, 3410r
- 3420p, 3420r (P> 0.4 bar)
- 3420p, 3420r (P ≤ 0.4 bar)
≤ ± 0.5% of span
≤ ±0.25% of span
≤ ± 0.5% of span
Output type (configurable)*
Max switching current
400 mA, short-circuit
protection
Type of switch contact outputs
(specified in ordering code)
NC and NO
Max switching current (contact type)
*Configurable by user. See Setup manual for instructions.
* Accuracy includes non-linearity, hysteresis and repeatability (under IEC
60770).
2.2. Operating conditions:
2.2.1 The device was designed to operate in the following conditions:
- no aggressive vapors, gases and liquids in the environment;
- ambient temperature from -40 to +70 °С;
- permissible media temperatures depends on seal material, see Technical
specifications;
- sensor exposure (liquids, gases and vapors):
• ASZ 3420p, ASZ 3420r - media non-aggressive to stainless steel;
• ASZ 3410p, ASZ 3410r - aggressive media;
- atmospheric pressure from 84 to 106.7 kPa (group R1 under GOST R
52931);
2.2.2 Resistance to mechanical attack puts the device in group N2 under
GOST R 52931.
2.3 Operating limitations:
- medium should be free from crystallizable impurities, contaminations and
dust;
- connect the device where the medium is still or almost still and produces
no vortices;
- install DZ 10 or the like pressure snubber before the device if the system
can produce hydraulic shocks;
- use impulse tubing (pre-filled with water) when measuring vapour
pressure.
1
2
3
4
5
DO NOT:
allow voltage exceeding maximum specified for the transmitter;
use any objects to touch or otherwise apply mechanical force to
the diaphragm;
use transmitters bearing visible signs of mechanical damage;
use transmitters in inappropriate climatic conditions;
allow medium temperatures above or below the limits specified
for the transmitter.
3 Design and operation
3.1 Diagrams of Figure 1 explain the principle of operation of the device.
Figure 2 - Structural diagram
Analog-to-digital converter (ADC) receives signal from the sensor and
sends it to the microprocessor that filters, corrects, scales it, generates
signals for switches (K1, K2) and outputs a normalized analog signal linear to
the pressure measured. Digital representation of the measured pressure can
reach a PC via P-Conf software (ASZ 3410p and ASZ 3420p models need to
have their analog outputs off to transfer data to PC).
3.2 LEDs 1 and 2 (located on the side, next to electrical connector) light up
when the pressure is within the keys tripping range.
This manual covers ASZ pressure switches (hereinafter referred to as
"switch" or "device"); it contains technical data, description of design and
other information necessary for proper application and maintenance of the
device.
See datasheets at http://piezus.ru for complete specifications.
Production regulated by TOR 4212-000-7722857693–2015.
Terms and abbreviations used in the manual:
Span – measurement range; NC - normally closed (NC contact);
NO - normally open (NO contact); PC - personal computer;
DC - direct current.
1 Purpose of the device
1.1 Pressure switches find application in monitoring, protection, alarm and
control systems in heat and power installations, air conditioning systems,
various industrial environments and public utilities.
1.2 The device:
- proportionally and linearly converts the pressure measured into a
normalized output signal:
3410p, 3420p - voltage, 1 ... 5 V; 3410r, 3420r - current, 4 ... 20 mA;
- compares current pressure value to the preset thresholds and outputs two
discrete signals when the monitored parameter crosses those thresholds (as
prescribed by the selected operation algorithm, hysteresis or window);
2 Technical specifications
2.1 General technical data
2.1.1 Refer to the device's passport and label (sticker) for span and accuracy
info.
2.1.2 P-Conf communication interface allows controlling value of the
measured pressure from a PC, as well as changing operation modes and
parameters as required.
2.1.3. Power supply - 12 ... 36 V (DC), - rated voltage - 24 V.
2.1.4 Current consumption, max: models 3410r, 3420r - 100 mA;
models 3410p, 3420p – 10 mA (excl. key outputs load).
2.1.5 Power consumption, max - 3.6 W (0.36 W for "p" models).
2.1.6 See Supplement A for design of the devices. Overall dimensions: 3410p
and 3420p - Ø28x90 mm; 3410r and 3420r - Ø48 × 120 mm.
2.1.7 Weight, max: "p" models - 0.15 kg; "r" models - 0.25 kg.
2.1.8 Housing ingress protection (GOST 14254) - IP65.