Step 2:
Non Power Mount
Step 1:
Power at Ceiling
1. Layout mounting/ junction box locations. Begin row
with fixture label at first mounting point.
2. Install 4-octagonal junction box to structure adjacent to
power feed mount locations.
3. Attach crossbar to junction box.
4. Run SJT power cord through canopy and into junction
box. Secure using provided strain relief.
5. Make necessary power connections.
6. Feed Aircraft cable through coupler and secure canopy
to junction using coupler (provided).
1. Install 1/4-20 studs to structure at all mounting points
(3/4” below ceiling plane.)
2. Feed aircraft cable through coupler (if applicable).
5. Secure coupler assembly to 1/4-20 bolt or stud.
AC - to - ST Mount
EDGE EX33
EX44
© 2017 Pinnacle Architectural Lighting
EdgeEX33_44_Booklet_January 2017
T5/T5HO/T8/LED
7 of 25
1. This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the
construction and operation of the product.
2. Minimum 90ºC supply conductors
3. All electrical connections must be performed by a certified electrician to applicable local and national electrical codes.
4. Fixtures must be mounted directly to structure.
5. The holding strength of AC cables cannot be guaranteed if the cables are damaged in any way.
Return to
Main Menu
AC cables with damage, bends, kinks, fraying, or knots must be discarded and replaced with new components. Never install a fixture where the AC cable is more than 5 degrees from perpen-
dicular to the fixture. Fixtures are never to be raised by the cables (instead, lift the fixture up and adjust the cable position). Overtightening of hardware on grippers can damage AC cables. Never
exert force down onto the top of the fixture once it is hanging by safety cables. Never cut safety cables prior to installation. The first zip tie on the SJT and AC cables below the ceiling/canopy
must be no closer than 12” from the ceiling/canopy
4 - Octagonal
Junction Box
(by others)
5” Power Canopy
Strain Relief
18ga. SJT Cord
Cross-Bar
Conduit and Fittings
(by others)
1/4-20 Stud
#8 Junction
Box Screws
Coupler
Aircraft Cable
* Stud sits 1/2”
Below Ceiling Plane
1/4-20 Stud
(by others)
Aircraft Cable
Coupler
2” Non-Power
Canopy