3.2 QUICK REFERENCE
Notes when visiting for service
1. Notes when disassembling/reassembling
1Rear case
When reassembling the rear case, the screws must be tightened in a
specific order. Be careful not to tighten them in the wrong order forcibly.
For details, see "Rear Case" in "7. DISASSEMBLY".
2Attaching screws for the HDMI connector
When attaching the HDMI connector after replacing the Main Assy,
secure the HDMI connector manually with a screwdriver, but not
with an electric screwdriver. If you tighten the screws too tightly
with an electric screwdriver, the screw heads may be damaged, in
which case the screws cannot be untightened/tightened any more.
2. On parts replacement
1How to discharge before replacing the Assys
A charge of significant voltage remains in the Plasma Panel even
after the power is turned off. Safely discharge the panel before
replacement of parts, in either manner indicated below:
A:
Let the panel sit at least for 3 minutes after the power is turned off.
B: Turn the Large Signal System off before the power is turned off
then, after 1 minute, turn the power off.
For details, see "5.6 [1] PANEL DRIVE-POWER ON/OFF
FUNCTION".
2On the settings after replacement of the Assys
Some boards need settings made after replacement of the Assys.
For details, see "8. EACH SETTING AND ADJUSTMENT".
3. On various settings
1Setting in Factory mode
After a Mask indication into the panel is performed, be sure to
set the Mask setting to "OFF" then exit Factory mode.
Adjustments and Settings after replacement of the
Assys (Procedures in Factory mode)
1. Digital Video Assy:Transfer of backup data
1Select {PANEL FACTORY}, {ETC}, then {BACKUP DATA}. (After entering Factory
mode, press [MUTING] once, press [ENTER/SET], press [j] seven times, then
press [ENTER/SET].)
2Select {TRANSFER}, using [l], then hold [ENTER/SET] pressed for at least 5
seconds.
3After transfer of backup data is completed, {ETC} is automatically selected, and the
LED on the front panel returns to normal lighting.
2. MAIN Assy: Execution of FINAL SETUP.
1Display Page 3/11 of Factory menu.
(To display this page, enter Factory mode then press the [P/CH +] three times.)
2Set the factory-preset value to {FINAL SETUP}, using the [l].
2Press [MUTING], press [i], press [j], then press [MUTING].
“SET” is displayed in red then disappears. Then the setting is completed.
3. POWER SUPPLY Unit: Clearance of the accumulated power-on count
and maximum temperature value
1Select {PANEL FACTORY}, {ETC}, then {P COUNT INFO}.
(After entering Factory mode, press [ENTER/SET], press [j] seven times, press
[ENTER/SET], then press [j] six times.)
2Press [l] to select "CLEAR". Hold [ENTER/SET] pressed for at least 5 seconds.
After clearance is completed, "ETC" is automatically selected. Clear the maximum
temperature value (MAX TEMP) in the same manner.
4. Other Assys: Clearance of the maximum temperature value
1Select {PANEL FACTORY}, {ETC}, then {MAX TEMP}.
(After entering Factory mode, press [ENTER/SET], press [j] seven times, press
[ENTER/SET], then press [j] seven times.)
2Press [l] to select "CLEAR". Hold [ENTER/SET] pressed for at least 5 seconds.
After clearance is completed, "ETC" is automatically selected.
How to locate several items on the Factory menu
1. Confirmation of accumulated power-on time and power-on
count
After entering Factory mode, press [P/CH +] four times.
2. Confirmation of the Power-down and Shutdown histories
1Panel system
PD: After entering Factory mode, press [ENTER/SET], then press [j]
twice.
SD: After entering Factory mode, press [ENTER/SET], then press [j]
three times.
2MTB section
After entering Factory mode, press [P/CH +] five times.
3. How to display the Mask indication
1Mask indication in the panel side
1. Select {PANEL FACTORY} then {RASTER MASK SETUP}.
After entering Factory mode, press [ENTER/SET], then press [j]
8 times.
2. Press [ENTER/SET], then select a Mask indication, using [i] or [j].
{ } : Item on the Factory menu
[ ] : Key on the remote control unit
" " : Screen indication
Quick Reference upon Service Visit 1
Notes, PD/SD diagnosis, and methods for various settings
1Rewriting software
2No backup
LED Display Information
B
R
B
R
B
R
B
R
3PD (2-15)
4SD (1-15)
For indication patterns other than
described below, see 5.1 [1].
Item
Major Type Detailed Type
No. of LEDs
flashing
No. of LEDs
flashing
Red 2
Red 3
Red 4
Red 6
Red 7
Red 8
Red 10
Red 11
Red 12
Red 15
POWER
SCAN
SCN-5V
Y-DCDC
Y-SUS
ADRS
X-DCDC
X-SUS
DIG-DCDC
UNKNOWN
Abnormality in the Sequence
LSI
Failure in MDU device communication
Abnormality in RST2 power decrease
Abnormality in panel temperature
Short-circuiting of the speakers
Failure in communication with
the module microcomputer
Failure in MAIN microcomputer
3-wire serial communication
Failure in IIC communication
with the main microcomputer
Abnormality in FAN
High temperature of the unit
Failure in the power supply
Main EEPROM
SD
PD
Blue 1
Blue 2
Blue 3
Blue 4
Blue 5
Blue 6
Blue 7
Blue 8
Blue 10
Blue 11
Blue 13
Blue 15
Communication error, Drive stop, Busy,
Version mismatching (hardware, software),
Version mismatching (hardware, backup memory),
Version mismatching (hardware, DIGITAL memory)
Digital EEPROM, Backup EEPROM, DAC IC
–
Abnormality in high temperature, Abnormality
in low temperature
–
–
MULTI, IP microcomputer
Audio IC, RGB switch, Main VDEC, VDEC
SDRAM, AD/PLL, HDMI, Temperature
sensor, Expansion I/O, DA for FAN
FAN2
–
DC-DC Converter power decrease
Main EEPROM communication error