1. Starting situation: Normal off circuit
In the existing off circuit (Figure 1) an additional lamp (lamp B) is
to be installed and is to be separately switchable (while retaining
the existing off switch and the existing electrical installation). This
is very easy with the ES1000W as explained below.
2. Circuit switching extension using the ES1000W
To install the ES1000W, first the connection between the off
switch and lamp A shown in Figure 1 is separated.
The ES1000W can then be wired as shown in Figure 2. The use of
a 4-way plug terminal is recommended. The lamp that is most fre-
quently used is to be wired to connection LS1, because this is the
first to be switched on when the switch is actuated. This is lamp A
in the example.
3. Mode of operation
Closing the switch switches on lamp A. Lamp B remains switched
off. Actuating the switch again (switch off and then on again
within 1-2 sec.) switches off lamp A and switches on lamp B at the
same time.
Actuating the switch again (switch off and then on again within
1-2 sec.) switches on both lamps A and B.
Actuating the switch again (switch off and then on again within
1-2 sec.) returns to the first switching state: lamp A on and lamp B
off.
If the switch remains switched off for longer than 2 seconds the
ES1000W returns to its basic state. Switching on again results in
switching state 1 again, as shown in table 1.
Notes:
The currently set switching state can change after a power cut!
Make sure that the terminal connections in the circuit are secure!
Possible causes of NON function:
•N-connectionnotcontacting
•Bouncinglightswitch
•CapacitancesbetweenN&L Table 1
Figure 1
Figure 2
Switching state LampA LampB
1. Normal swich on
(state after swich off
> 2 sec.)
ON OFF
2. Short swich off-on
( < 2 Sek.)
OFF ON
3. Short swich off-on
( < 2 Sek.)
ON ON
4. Short swich off-on
( < 2 Sek.)
(swich state 1)
ON OFF
swich
4-way plug
terminal
ES1000W
L
AB
LLS1LS2 N
N
230 V ~ AC
L
N
A
230 V ~ AC swich
Manufacturer’s guarantee conditions
1. The guarantee is only valid in combination with the original in-
voice, sales receipt or a confirmation of the guarantee period
from PE. The repair or replacement of the device or of individual
parts does not result in an extension or renewal of the guarantee
period.
2. The decision to repair or replace a faulty device or component
parts shall be taken at the sole discretion of PE. The relevant re-
placed device or component part shall then become the property
of PE.
3. PE attaches great importance to good service which ensures that
repairs are to be carried out quickly and reliably. For this reason,
all guarantee repairs shall be carried out by PE itself or by ap-
pointed specialist dealers. If repairs are carried out during the
guarantee period by parties who are not authorised or appoint-
ed, the guarantee shall become null and void.
4. After the end customer has reported the fault, the faulty device
shall be replaced with a comparable model once PE has granted
its approval for replacement. This replacement device becomes
the property of the end customer only after the faulty device has
been handed over and only if the guarantee claim is not rejected
within 4 weeks of the faulty device being handed over to PE. The
faulty device is to be handed over without delay, within five (5)
working days at the latest. Otherwise the end customer shall be
charged for the replacement device in accordance with the cur-
rent end consumer price.
5. The guarantee from PE does not include the following items:
a) Routine checking, maintenance and repair, and the replacement
of wearing parts
b) Faults that have resulted from incorrect operation or incorrect
installation
c) Damage caused by storms, water, fire, surge voltage, force ma-
jeure or war, incorrect connection to the power supply, insuffi-
cient ventilation or other causes that PE has no influence upon.
d) Use of the product outside of the scope of the product specifica-
tion (only to be used for lighting purposes)
e) Incorrect mounting or installation
f) Damage caused by transport or by inappropriate packaging
g)Products with no series number or where the series number has
been changed, deleted, removed or otherwise rendered illegible.
The guarantee period has no bearing whatsoever on customers’
statutory guarantee entitlements or other contractual entitle-
ments from dealers and does not limit these entitlements in any
manner.
In the case of complaints or claims regarding faults that fall within
the scope of these guarantee exclusions, PE reserves the right to
charge the customer for any costs that may arise from these com-
plaints or claims.
PE and its distributors are not liable – to the extent permitted by law
– for direct or indirect damages or losses. Claims for compensation
for damages based on this guarantee are excluded to the extent
permitted by law.
Safety requirements
Always disconnect the power supply before carrying out installa-
tion or maintenance. Avoid high ambient temperatures.
The safety information and technical specifications must be strictly
adhered to.
The installation must be performed by trained personnel, e.g. em-
ployees of an electrical installation company (electricians as per DIN
VDE 1000-10).
Protect the product against dust, moisture and splashes.
The ES1000W may only be installed in other housings such as balda-
chines or junction boxes etc.
During installation, care must be taken to ensure that the connec-
tion wires are not subjected to mechanical stresses. When using the
device in existing circuits, ensure that the previous installation is
in a standards-conformant state (non-intact terminals, bouncing
switches). The unblocking mechanism must be used when removing
the wires.
Our general terms of delivery for electronics products and services can be viewed at www.plaettner.com or requested by
telephone.
Thank you for choosing this product. We are sure that your new
device will provide you with a lot of enjoyment in the coming years.
Plättner Elektronik GmbH (PE) provides a guarantee of 24 months
from the date of purchase for this product. If a change of owner-
ship takes place due to the product being sold on, the guarantee
shall be based on the remaining guarantee period from the date of
initial purchase. The validity period varies from country to country
depending on the locally applicable laws. For example, a period of
just one (1) year applies in Great Britain. In the case of products
with a guarantee period of over two (2) years, guarantee claims
or other questions relating to the guarantee that arise after the
two (2) years have expired should be addressed directly to PE or its
distributors. The address and telephone number can be found at
www.plaettner.com.