Platinum CCTV PT-BF5421-T Manual

Human Temperature Measurement Camera
Installation and Setup

Preparation
Overview
1
2
3Installation
4
5
6
Configuration
Installation Checklist
FAQ

Overview | Application scenarios
•This camera is ideal for installation as a pre-screening method to be placed in areas where personnel are on duty to conduct
further screening of body temperature and to enact company protocols when individuals are found to have abnormal skin
temperatures. This solution is popular in places like passenger stations, railway stations, subway stations, airports,
manufacturing facilities, hospitals and any other security check entrances. It is recommended to deploy our PT-BF5421-T
camera and blackbody (real-time calibration tool) at each entrance of the facilities to ensure that all persons must pass
through an inspection point. This camera has a built-in configurable audio and visible light to alert when persons are found
above the expected temperature and can be connected directly to a laptop or computer for viewing through a web browser,
or optionally connected through our MicroNVR or AVM NVR software for recording and additional alerting capabilities.
When properly installed and configured, this camera provides accuracy of ±0.3°C / ±0.54°F at normal body temperatures.
This is the reason it is important to follow these directions for proper configuration and setup.
Airport Station Hospital Enterprise
This product is not a medical device and is not intended for use in the diagnosis, cure, mitigation, treatment or prevention of any disease or other medical condition.

Overview | Your Pre-Screening Plan
The PT-BF5421-T camera should be used as a pre-screening device as a part of your building or business security plan.
Visitors
Security Line Non Contact
Body Temp.
Measurement
Pass
Normal
Abnormal
Staff Review Start Your
Emergency Plan
Abnormal
Confirmation
This product is not a medical device and is not intended for use in the diagnosis, cure, mitigation, treatment or prevention of any disease or other medical condition.

Overview | Topology
Solution 1:
PT-BF5421-T Camera + Blackbody
+ Laptop/PC Local Access
Solution 2:
PT-BF-5421-T Camera +
Blackbody + MicroNVR + TV/LCD +
Laptop for Remote Access and Alerting
Note: Laptop, TV, Monitor, PoE Switch and Cabling shown for layout only. Not included with purchase.

Overview | Products
Temperature measurement
Blackbody
Working temperature: 40.0 ℃
(ring temperature + 5.0 ℃~ 50.0 ℃
adjustable)
Temperature resolution: 0.1 ℃
Temperature measurement accuracy:
±0.2 ℃(single point)
Temperature stability:
±(0.1 ~0.2) ℃/ 30min
Effective emissivity: 0.97 ±0.02
Power supply: 220VAC 50Hz
Ambient temperature and humidity: 0
~ 40 ℃/ ≤ 80% RH
Uncooled vanadium oxide infrared focal
plane detector
Detector resolution: 400*300
Spectrum range: 8 μ m ~ 14 μ M
Thermal imaging lens: 13mm
Temperature measurement range:
30 ℃~ 45 ℃
Thermal sensitivity: ≤ 50mk @ f / 1.0
Visible light: 1 / 2.8 "CMOS
Sound warning:
Built in white warning light & audible alert
Resolution: 1080p
Temperature measurement accuracy:
±0.54°F (0.3 ℃) with blackbody
±1.8°F (1.0 ℃) without blackbody
Optional adjustable tripod design with
Special camera and blackbody
mounting plates are ideal for fast-
deployment and easy adjustment.
Please protect camera and blackbody
From being bumped/knocked over
To prevent damage and to ensure
proper calibration of both devices.
Adjustable Tripods (optional) Permanent Brackets (optional)
Optional junction boxes and pole
mount brackets may be used to
permanently affix the camera and
blackbody to the building masonry or
structure poles to keep them in
position for permanent or semi-
permanent use.
The optional MicroNVR with Advanced
Video Management software extends
the features and functionality of the
Thermal camera. It provides the ability
to monitor the Thermal camera output
from multiple PCs/Macs/Laptops and
phones from anywhere in the world
(when connected to the internet). The
MicroNVR also provides the ability to
configure email, pop up and text alerts
to notify key personnel when
individuals outside normal body temp
range have entered the facility.
AVM MicroNVR
Thermal Network Bullet Camera
PT-BF5421-T

Overview | Solution Features
Easy deployment
Thermal camera + Blackbody
+ ordinary PC constitutes a
quickly deployed body
temperature pre-screening
station. Optional tripods
make setup even easier.
Safety
Non-contact thermography to
avoid the risk of cross
infection during pre-screening
process. This makes it a key
component of a complete
security solution for
businesses and
transportation.
High-efficiency
Stop the long lines and
difficult delays. By scanning
quickly, this thermal camera
allows people to move at
normal speeds (detection
times down to 1 sec)
High detection rate
The head detection
temperature measurement
can avoid the interference of
other non-human targets,
and the temperature
measurement accuracy can
reach ±0.54 °F with
blackbody
Advanced Alerting
When combined with our
AVM NVR software or
MicroNVR recorder with
AVM software, alerts can be
not only heard and seen at
the camera, but from
anywhere with authorized
users over the internet.

Preparation
Overview
1
3Installation
4
5
6
Configuration
FAQ
2
Installation Checklist

Preparation | Survey
•The installation area shall be a relatively isolated and stable environment without wind or rapid changing ambient temperatures.
Avoid outdoor areas for best accuracy. It is not suitable for environments with strong air flow, rapid ambient temperature changes or
strong electromagnetic interference or vibration.
•Position the camera so that the flow of traffic is towards the camera to ensure the camera can detect the temperature of people with
their forehead and/or eyes.
•Keep out of direct sunlight or high ambient temperatures. Avoid interference of heat sources such as microwave ovens, electric
heaters, hot water heaters, high-power lamps, radiators, etc. to avoid damage to the camera or blackbody.
•The visible light channel of the camera requires sufficient illumination with minimal backlighting to properly register faces.
It is recommended to use railings or
other devices to guide personnel in the
correct direction towards the camera for
detection for best accuracy and stability.
Recommended Positioning
Insufficient
illumination
Too much
backlighting
Incorrect direction
of traffic
Avoid these scenarios

Preparation | Survey
•When there is a large difference between indoor
and outdoor temperatures, it is recommended to
route people through a back and forth S shaped
route to allow the temperature of a person’s
forehead to stabilize (reducing impact of
excessive heat from outside or excessive cooling
of the skin)
•It is recommended to keep thermal camera away
from an exterior door where hot or cold air might
rush in when it is opened.

Preparation | Device & Tool List
Note: Tripod installation is used for this example for portable indoor installations. Optionally camera and blackbody can be mounted with brackets/junction boxes.
Equipment Specification type Appearance Remarks
Thermal camera PT-BF5421-T
Thermal camera 13mm lens, best monitoring distance ~10ft (3m)
Blackbody JQ-D70Z
Blackbody provides continuous calibration for camera
Tripod and Connector
(Optional)
Tripods (optional) for rapid deployment of camera and blackbody along with adapter
plates for easy mounting.
Computer Notebook / Desktop (NOT INCLUDED)
(not included) for configuration and setup
MicroNVR
(Optional) NVR Recorder with AVM Software
Optional MicroNVR recorder for recording and/or alerting. Includes our AVM
recording software.
Software
(Optional) AVM software for Recording
Optional AVM recording software to install on your own PC/Laptop
PoE Switch
(Optional) Standard PoE Switch
An optional standard PoE network switch is recommended for powering the thermal
camera and connecting to your computer or NVR recorder.
DC12V power adapter
(Optional) AC to DC Power Supply
Optional AC to DC power supply to provide power to the Thermal Camera (only if
PoE switch above is not used. Power
-AC100V~240V-12V 2A
Tape Measure 20 feet or more
Tape Measure for marking out distances and heights of camera and blackbody

Network cables, Surge Protectors
(not included) several
Each setup may require different lengths of extension cords and network cables
to permit connection. These are not included with the camera.
Traffic routing railings
(not included) several
You may need additional railings in order to properly route people past your
thermal camera to ensure that all people are scanned and in the correct direction.
These are not included with this camera as every site will have different
requirements.
Footprint stickers
(not included) several
Stickers or paint markings to show people the route of traffic into the facility for
testing. These are
not included with the thermal camera system.
Screwdrivers, Wire Clamp, Electrical
tape, cable ties, RJ-45 plugs, etc
(not included)
several
These are also
not included
Preparation | Device & Tool List
Equipment Specification type Appearance Remarks

Preparation
Overview
1
2
Installation
4
5
6
Configuration
FAQ
3
Installation Checklist

Installation | Installation Requirements and Precautions
•The blackbody should be installed just above and to the side of where
persons will be walking past the camera. The blackbody heat radiation
surface should face the camera. The black body can be to the left or right
side where a person will be walking.
Note: The blackbody should not be installed too close to the edge of the thermal
image. It is recommended to divide the image into 16 equal parts as shown. Mount so
that the blackbody is near the intersection point on the upper left or upper right of the
image.
Protect the blackbody and camera from damage, especially if opting to use the tripods!

Installation | Installation Requirements and Precautions
Camera mounting height Camera angle Blackbody Mounting Height Distance between Blackbody and Camera Distance between forehead
and camera Width at the best distance
6 ½ ft (~2m) Downward
angle of < 30 °6 ft (~ 1.8m) 10 ft (~3m)
10ft (~3m)
(No blackbody 6.5ft (~2m))5ft (~1.5m)
The installation height of camera and blackbody and the distance from blackbody to camera are important for optimum accuracy as shown in the table below.
The distance between a person’s forehead and the camera should be the same as the distance between the blackbody and the camera.
PT-BF5421-T(13mm)Installation Guide

Installation | Installation Requirements and Precautions
Announcements :
•Do not touch or spray the blackbody heating surface. Scratches, smudges and dirt will lead to the decrease of blackbody
accuracy and/or failure. This will affect the accuracy of your calibration.
•The blackbody equipment uses AC120V power supply, make sure you use a grounded outlet/receptacle to prevent shock!

Installation | Installation Requirements and Precautions
Person standing at distance of ~10ft from
camera at same distance as blackbody
This is an example setup of the thermal camera and blackbody. The height of the
thermal camera from the ground is 6.5ft, and the height of the blackbody from the
ground is 6ft. The best detection position of the human body is parallel to the
blackbody (~10ft away from the camera), and the camera's pitch angle is less than
30 °, facing the forehead of the face and the radiation surface of the blackbody
Note: During field installation, direct contact
with the outside air should be avoided when
possible, otherwise the temperature
measurement may be inaccurate due to the
influence of indoor and outdoor airflow
convection.
Blackbody
Height 1.8m
Thermal Camera
Height 2m
The Thermal Camera is 3 meters from the Detect Line

Installation | Ground Sticker & Notice Board
Note:
Install any guard rails, railings, fences or other stickers (not included with
the thermal camera system) to ensure that people know the correct
direction of flow for appropriate temperature scanning.

Blackbody connection:
The black power supply is AC120V, with standard AC three-
hole plug, the line length is 6ft (the socket must be grounded)
Camera connection:
Connect camera to a PoE switch or with optional DC power
connection then connect network cables to PC and/or MicroNVR
recorders to allow access to camera over local network.
Installation | Thermal Camera & Blackbody

Preparation
Overview
1
2
Installation
3
5
6
Configuration
FAQ
4
Installation Checklist
Table of contents
Popular Temperature Controllers manuals by other brands

Auber Instruments
Auber Instruments SYL-1512A instruction manual

AERMEC
AERMEC NRL0280E Installation and maintenance manual

urmet domus
urmet domus Bitron Home 902010/27 Quick start manual

Doepke
Doepke Dupline DTS 1 operating instructions

Aegis
Aegis ECS-180neo user manual

Huber
Huber Pilot ONE Technical bulletin