Plum MacR6 User manual

PLUM Sp. z o.o. Ignatki, ul. Wspólna 19, 16-001 Kleosin tel. +48 857497000 fax +48 857497014
INSTALLATION MANUAL
Name: Pressure recorder
Type: MacR6
Variant: Z0 & Z0-P
Communication protocol: GAZMODEM2
1. PREPARING THE DEVICE
•Remove six TORX T10 screws from back of the
cover.
•Next place the Micro SIM card into the holder as
shown in the picture. There is no need to remove
the battery to insert the SIM card.
•In the next step put the device together and
tighten the screws with 0,65-0,75Nm
momentum.
SIM card and antenna assembly is allowed only out of the hazardous explosive
zone.
•Delivered devices may have the display turned off. To wake it up close the magnet (i.e. OptoBTEx
head to the OPTICAL INTERFACE window. SLEEP 3 sign will appear. Repeat closing magnet until
START sign will appear. Procedure presented in the tutorial movie => red QR code.
RELATED TO FIRMWARE:
PROGRAM SERIE: MacR6-P S001.04
Document version: 1.1
January-2019

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
2
•Turn on the OptoBTEx interface, put it on the OPTICAL INTERFACE window.
Turn on the DATA LOGGER CONFIGURATOR app on Android mobile device.
Link to download the freeware application => green QR code.
2. WALL OR PIPE ASSEMBLY
MacR6-Z0 data logger is the device designed for installation in hazardous explosive zones 0, 1,
2. Ex marking II 1G Ex ia IIA T4 Ga.
Connecting external antenna cable is allowed only out of the explosive zone.
Minimum requirements for improving the safety and health protection of workers potentially at
risk from explosive atmospheres are prescribed in Directive 1999/92/EC of the European
Parliament and of the Council of 16 December 1999 (ATEX 137 'Worker Protection Directive').
Installation environment must guarantee the strong GSM network signal of the vendor whose
SIM card is used in MacR6.
Data logger placement is utilized by using dedicated mounting kit.
•attach the holder to the wall using mounting pegs, or horizontally and vertically to the gas pipes
using cable ties
•place the recorder inside the holder until it clicks
Protection level will be kept only with proper cables diameters usage, tightening cable glands,
sealing ring arrangement and tightening the front cover with 0,65Nm momentum (maximum
0,75Nm).
In case of flooding the opened device immediately take off the battery. That device has to be
examined by the manufacturer.

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
3
3. SENSORS CONNECTION
Connect the pressure sensor to the gas flow installation. (MacR6-Z0-P & MacR6-Z0-P/2P):
It is required to connect the sensor using the shut-off valve.
Pressure sensor in MacR6-Z0-P device
Before assembly pressure sensor it is required to reset its indications (compensation of atmospheric
pressure). It can be done via Android application (by option in menu Options/Pressure Zero/Make fixes
and Save data) or via PlumCONF application (set „P offset st.” parameter to value: 1 =>for 1-pressure
sensor version of device). “P CAL” will be shown on LCD.
After pressure sensor assembly it is recommended to perform SEr 8 menu to begin pressure
measurement test (measurement every 5 seconds for one minute). Value of pressure will be shown on
LCD.
4. CONNECTION WITH SMARTPHONE
•OptoBTEx Bluetooth pairing code: 1234. Blue QR code contains the movie presenting proper
connection between smartphone and MacR6 device.
LED diode must be on the right side looking on the front of the MacR6. During
transmission its musts flash constantly.
Configuration using computer is more detailed in „Configuration using PC”
section.
5. COMMUNICATION WITH THE DEVICE
•Through correct device readout on the main screen will be presented the device nameplate. It
consists of devices name, variant, serial number, firmware version. After loading all the parame-
ters, the application will proceed to main configuration window.

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
4
6. CONFIGURATION PARAMETERS
•Main application window presents parameters necessary for proper device operation.
Additional parameters:
oPIN code to SIM card
oDevice password (by default: 4096)
oLocalization parameters
NOTE: Application is designed for whole MacR6 product family. Types of presented pa-
rameters can be different for each product type.
•Choosing "MORE PARAMETERS" presents options common for bigger amount of measuring sites.
Values able to adjust:
odiagnostic phone number (i.e. installers cell phone number which will get the SMS
message with installation summary). Way of typing: XXYYYYYYYYYYY where XX -
country destination number without +, YYYYYYYYYYY - phone number
odata server address - way of typing: address:port, i.e. www.ewebtel.com:80
otime synchronization option (winter/summer/auto change)
•Choosing "OPTIONS" presents additional parameters:
oInfo - device nameplate, information about last measured GSM range signal value -
CSQ, device clock
oClock programming - synchronizing devices clock with the smartphone including time
synchronization options (winter/summer/auto change)
oPressure limits - MacR6-P allows for setting four pressure limits - low limit warning and
exceedance, high limit warning and exceedance. After exceeding the warning level user
will get the information about exceedance risk.
oService APN - APN used for communication with FTP server.
NOTE: It is essential to ensure if the recorder clock is set correctly. If not, it is required
to set it using menu OPTIONS and Clock programming.

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
5
7. CONFIGURATION SAVING
•After setting all desired parameters use the "SAVE
DATA" button on the bottom of the window. Wait for
the confirmation notification on screen.
•Blue markers near modified parameters will change
to green.
•Setting the configuration will cause automatic instal-
lation mode SEr 5 start. If not, SEr 5 must be per-
formed manually.
•Diagnostic phone number used for summary SMS
message can be programmed only while SEr 5 is
displayed on the device.
8. CONFIGURATION USING PC
MacR6-P can be configured using PlumCONF freeware PC software. Software is available to download
using purple QR code.
Key parameters:
Parameter
name
Description
Update
Schedule Type
FTP connection schedule: 1 –once a day; 2 –once a week; 3 –once a month
Schedule Type
Data sending schedule: 1 –once a day; 2 –once a week; 3 –once a month
Report Hour
Hour of sending report to the server
Report Day
Day of sending report to the server –parameter ignored if Schedule Type = 1
Registration
Report Hours
Decimal value of additional report hours binary vector –extended info in user
manual
Report Delay
Delay of sending report according to Report Hour. 0 - no delay, 1 - delay from 0-10
minutes, 2 - delay from 10-20 minutes, 30 - delay from 20-30 minutes
Registration
period
Registration period; possible to set total dividers of 60
PIN
PIN to SIM card
APN
APN used for data sending
Update APN
APN used for FTP connection
Data Server
Address
Data server address, i.e. www.ewebtel.com:80
Time Auto
Change
0 - auto time change winter/summer; 1 - only winter time; 2 - only summer time
P Min Alarm
Lower pressure limit, exceeding will cause the alarm
P Max Alarm
Upper pressure limit, exceeding will cause the alarm
P Min Warning
Lower pressure limit warning about possible pressure drop
P Min Warning > P Min Alarm
P Max Warning
Upper pressure limit warning about possible pressure increase
P Max Warning < P Max Alarm
P offset st.
Clearing pressure sensors indication; necessary to be done before the installation
•set to: 1 => for 1-pressure sensor version of device

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
6
9. INSTLLATION MODE
•Manual SEr 5 option turning on can be done using strong magnet or OptoBTEx head by closing it
to the OPTICAL INTERFACE window. Repeat that step until SEr 5 sign will appear. Installation
process will start when all indicators disappear.
•Installation process startup is marked by blinking antenna symbol
on display. This means that the internal modem is turned on.
•After few seconds the GSM range indicator will flash constantly.
Number of bars determines the GSM range.
•Antenna symbol will be blinking for about minute, then it will flash constantly. Blinking
icon will appear, which means connecting with APN.
•In the next step together with icon the blinking data sending icon will appear.
•In the end, the device will proceed to normal work showing periodically date, hour and registered
parameters value. All of mentioned icons should flash constantly, which determines the correct-
ness of sending data.
10. DEVICE DISPLAY
On display there are presented periodically registered values, date and hour.
During normal device state following indicators can be visible:
•"SEr 7" menu allows for connection with server examination. During this
mode registered data from last billing day is sent. On display the "rEPort"
sign will appear. When finished - the symbol will appear.
•"SEr 6" menu allows for GSM signal range and antenna efficiency exam-
ination. This test lasts for about 1 minute, where on display current CSQ
level is presented. Mostly CSQ ≥ 9 is sufficient.
Battery level indicator
Sending data to the server / data sent.
APN connection indicator –visible together with indicator above

Pressure recorder MacR6-P
Installation manual v1.0 –December 2017
7
Variants
Analog inputs
Digital inputs
Digital outputs
Modem type
AI1
AI2
DI
DO
GSM
P-X
0
0
0
2G
P-X
1
1
3G
2
2
Description:
0 –not installed
P –pressure sensor
X measurement range, i.e.;
0.1G –0÷10 kPa
6G –0÷600kPa
6A - 80÷600kPa abs
DI/DO –0, 1 lub 2 –digital inputs or outputs amount
2G –modem 2G
3G –modem 3G
Sample marking:
TECHNICAL SUPPORT
•Technical Department
Phone: +48 85 749 70 08
serwis@plum.pl
PLUM Sp. z o.o.
Ignatki, ul. Wspólna 19 , 16-001 Kleosin
www.plummac.com