Planar Monolithics Industries, Inc.
7311-F Grove Road
Frederick, MD 21704 USA
Phone: (301)662-5019 Fax: (301)662-1731
Web: www.pmi-rf.com Email: sales@pmi-rf.com
2
1. Control and Status
This section of the document describes the specifications for control and
status of the Limiter Switch Box, PMI Model No. PSD-6G18G-CD-2 via
external network (TCP/IP socket). The Network Attenuator Controller uses
an XPort Network to Serial Interface to interface the onboard
MicroController to the Network. Attached is the Datasheet and Users
Guide describing the XPort module and additional programming features.
The Limiter Switch Box, using the Default IP Address, listens on TCP/IP
Address 10.1.1.241, Port 10001 for external socket connections. Default
Network Mask set to 255.0.0.0. Gateway and DNS default set to 0.0.0.0.
Only one connection at a time is supported on the socket connection.
2. General Command Syntax
Commands are sent to the Limiter Switch Box, responses are received
from the Limiter Switch Box. All commands and responses are comprised
of ASCII characters. The Commands and Responses section of this
document provide the format and description of each of the commands and
responses. Every command must be terminated with a line feed character
(0x0a). Every command sent by the user to the Limiter Switch Box will be
followed by a response from the Limiter Switch Box to the user. The user
must wait to receive the response before sending another command. The
response can be one of two message types: a simple acknowledge
mnemonic (AK), a negative acknowledge mnemonic (NK) or a response
that contains the data associated with the command.