J
PRIM
3 2 14
12V
431 2
D
C1
EE
H
H
C
A
F
L
B1
B2BU.T.
PART. T1802A
Istruzioni d’uso
Gebrauchanweisungen
Notice d’emploi
Instructions for use
Instrucciones de uso 10/07-02 PC
607
043 926
Impianto di intercomunicanti fino a 5 posti interni con 1 posto esterno
Türsprechanlage mit internem Haussprechverkehr bis zu 5 interne Sprechstellen und 1 Türstation
Installation des combinés à intercommunication jusqu’à 5 postes intérieurs et 1 poste extérieur
Intercommunication installation for up to 5 Internal Units with 1 Entrance Call Unit
Instalación de intercomunicantes hasta 5 puntos interiores con 1 placa exterior
Modificare i collegamenti all’interno dei citofoni come segue:
- togliere il ponticello tra i morsetti 4 e 7
- spostare il filo del ronzatore dal morsetto 11 al 5
- aggiungere per ogni citofono 4 pulsanti art. 600ETE e collegarli, unendo
i morsetti 0 fra di loro e al morsetto 7
Interne Telefon-Verdrahtungen wie folgt ädern:
- Brücke zwischen del Klemmen 4 und 7 entfernen
- Summeranschluß von Klemme 11 nach Klemme 5 verlegen
- 4 Taste Art. 600ETE pro Telefon einbauen und alle Klemmen 0, die unter
ihnen anzuschließen sind, mit Klemme 7 verbinden.
Modifier les raccordements dans le combiné comme suit:
- enlever le shunt entre les bornes 4 et 7
- dépalcer le fil du ronfleur de la borne 11 à la 5
- ajouter pour chaque combiné 4 boutons d’appel art. 600ETE et les
connecter, en raccordant les bornes 0 entre elles et à la borne 7.
Modify the connections inside the telephones as follows:
- remove the jumper between terminals 4 and 7
- move the buzzer wire from terminal 11 to 5
- add to each telephone 4 pushbuttons art. 600ETE and connect
terminals 0 among them and then to terminal 7.
Modificar las conexiones internas de los téléfonos del modo siguiente:
- quitar el puente entre los bornes 4-7
- cambiare el hilo del zumbador del borne 11 al 5
- añadirt por cada téléfpno 4 pulsadores art. 600ETE y connectarlos
uniendo los bornes 0 entre si y con el borne 7.
1
2
Impianto di intercomunicanti fino a 2 posti interni con 1 posto esterno
Türsprechanlage mit internem Haussprechverkehr bis zu 2 interne Sprechstellen und 1 Türstation
Installation des combinés à intercommunication jusqu’à 2 postes intérieurs et 1 poste extérieur
Intercommunication installation for up to 2 Internal Units with 1 Entrance Call Unit
Instalación de intercomunicantes hasta 2 puntos interiores con 1 placa exterior
J
PRIM
3 2 14
12V
431 2
D
C1
EE
H
H
C
A
F
BB
G
Legenda / Erläuterung / Legende / Legenda / Leyenda
A
Alimentatore - Netzgeräte
Alimentation - Power supply
Alimentador
672 - 043 453
B
Citofono - Haustelefon
Poste téléphonique - Intercom
Téléfono
600 - 043 467
C
Pulsantiera - Türstation
Platine de rue - Front door pushbutton keyboard
Placa de pulsadores para la calle
Tersystem
C1
Pulsantiera - Türstation
Platine de rue - Front door pushbutton keyboard
Placa de pulsadores para la calle
SM - 500 - 900 - AV
D
Porter - Türlautsprecher
Portier électrique “Porter”
Speaker unit “Porter”
Portero eléctrico “Porter”
2659N - 043 932
Legenda / Erläuterung / Legende / Legenda / Leyenda
E
Serratura elettrica - Türschloß
Gâche électrique - Door lock opener
Cerradura eléctrica
F
Unità di commutazione - Umschaltrelais
Relais de commutation - Switching unit
Unidad de commutación
607 - 043 926
G
Suoneria - Klingel
Sonnerie - Buzzer
Timbre
H
Pulsante interno - Drucktaste - Poussoir porte d’antrée
Internal pushbutton for front door
Pulsador puerta d’entrada
I
Relè luce scale - Relais für Treppenhauslicht
Relais pour illumination escaliers
Relay for staircase lighting
Timer temporizador luz escalera
40.91 - 043 917
Modificare i collegamenti all’interno dei citofoni come segue:
- togliere il ponticello tra i morsetti 4 e 7
- Spostare il filo del ronzatore dal morsetto 11 al 5
Interne Telefon-Verdrahtungen wie folgt ädern:
- Brücke zwischen del Klemmen 4 und 7 entfernen
- Summeranschluß von Klemme 11 nach Klemme 5 verlegen
Modifier les raccordements dans le combiné comme suit:
- enlever le shunt entre les bornes 4 et 7
- dépalcer le fil du ronfleur de la borne 11 à la 5
Modify the connections inside the telephones as follows:
- remove the jumper between terminals 4 and 7
- move the buzzer wire from terminal 11 to 5
Modificar las conexiones internas de los téléfonos del modo siguiente:
- quitar el puente entre los bornes 4-7
- cambiare el hilo del zumbador del borne 11 al 5

This manual suits for next models

1

Other Bticino Switch manuals

Bticino H4585 User manual

Bticino

Bticino H4585 User manual

Bticino RW4003C User manual

Bticino

Bticino RW4003C User manual

Bticino HC4051A15US User manual

Bticino

Bticino HC4051A15US User manual

Bticino Living L4531 User manual

Bticino

Bticino Living L4531 User manual

Bticino 323002 User manual

Bticino

Bticino 323002 User manual

Bticino K4411CM2 User manual

Bticino

Bticino K4411CM2 User manual

Bticino RW4411CM2 User manual

Bticino

Bticino RW4411CM2 User manual

Bticino BTK4411C User manual

Bticino

Bticino BTK4411C User manual

Bticino K4411C User manual

Bticino

Bticino K4411C User manual

Bticino Livinglight N4027CM2 User manual

Bticino

Bticino Livinglight N4027CM2 User manual

Bticino L4003CW User manual

Bticino

Bticino L4003CW User manual

Bticino Megatiker MA-MH-ML 630-1250 User manual

Bticino

Bticino Megatiker MA-MH-ML 630-1250 User manual

Bticino Livinglight 3577C User manual

Bticino

Bticino Livinglight 3577C User manual

Bticino RW4027CW User manual

Bticino

Bticino RW4027CW User manual

Bticino BTK4003CWI User manual

Bticino

Bticino BTK4003CWI User manual

Bticino K4003CWI User manual

Bticino

Bticino K4003CWI User manual

Bticino Terraneo 336210 User manual

Bticino

Bticino Terraneo 336210 User manual

Bticino N4003DCW User manual

Bticino

Bticino N4003DCW User manual

Bticino RW4412CM2 User manual

Bticino

Bticino RW4412CM2 User manual

Bticino F67SR11 User manual

Bticino

Bticino F67SR11 User manual

Bticino K4027CIL User manual

Bticino

Bticino K4027CIL User manual

Bticino M7TE/2 User manual

Bticino

Bticino M7TE/2 User manual

Bticino LivingNow K4570CW User manual

Bticino

Bticino LivingNow K4570CW User manual

Bticino RW4570CW User manual

Bticino

Bticino RW4570CW User manual

Popular Switch manuals by other brands

Barksdale TempSwitch 2000 operating instructions

Barksdale

Barksdale TempSwitch 2000 operating instructions

Altronix NetWay2ES Series installation guide

Altronix

Altronix NetWay2ES Series installation guide

Cisco SGE2000 datasheet

Cisco

Cisco SGE2000 datasheet

AVCOMM 610FX2 Quick installation guide

AVCOMM

AVCOMM 610FX2 Quick installation guide

SECO-LARM SLI ENFORCER VIDEO EVT-PH16-4T2 manual

SECO-LARM

SECO-LARM SLI ENFORCER VIDEO EVT-PH16-4T2 manual

SMC Networks SMC TigerCard 10G installation guide

SMC Networks

SMC Networks SMC TigerCard 10G installation guide

H3C S3610 Series Operation manual

H3C

H3C S3610 Series Operation manual

Dali DH user manual

Dali

Dali DH user manual

StarTech.com SV441DUSBI instruction manual

StarTech.com

StarTech.com SV441DUSBI instruction manual

LevelOne 1650 user manual

LevelOne

LevelOne 1650 user manual

H3C S5120-SI Series installation manual

H3C

H3C S5120-SI Series installation manual

Cisco Catalyst 2960-48PST Product support bulletin

Cisco

Cisco Catalyst 2960-48PST Product support bulletin

Orbis ALPHA user manual

Orbis

Orbis ALPHA user manual

Huawei ACBox2000-21-D-A user manual

Huawei

Huawei ACBox2000-21-D-A user manual

Nice EDSB Instructions and warnings for installation and use

Nice

Nice EDSB Instructions and warnings for installation and use

Dell 5324 - PowerConnect Switch User guide addendum

Dell

Dell 5324 - PowerConnect Switch User guide addendum

ATEN US3312 user manual

ATEN

ATEN US3312 user manual

Edimax ES-5824PH manual

Edimax

Edimax ES-5824PH manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.