Pogo Automatic User manual

POGO® Automatic™
Blood Glucose Monitoring System
Quick Start Guide
Press. Test. GO.
Simply press nger
here for easy,
One-Step™ testing.
For Single Patient Use Only

If you are new to POGO Automatic, this guide will
help you learn the basics of automatic blood glucose
testing. For more information, refer to your POGO
Automatic Owner’s Manual included with your meter.
Practice First
To fully understand POGO’s unique automated testing,
it is recommended that you try a practice test.
• READ ALL INSTRUCTIONS, including PREPARE
FINGER and ADD MORE BLOOD
(if needed).
• PERFORM PRACTICE test.
Hello, please start here.
Ready to test checklist
I read all instructions
I carefully selected the right nger
I performed a successful practice test

Load Cartridge
INSERT TEST CARTRIDGE
and click door shut.
Cartridge will spin into place.
PRESS BUTTON to open
cartridge door.
Cartridge includes 10 complete tests

Prepare Finger to Test
Until you are familiar with POGO
testing, try placing a nger from
opposite hand rmly on top of test
nger for added pressure. This is
best if you have calluses or thick,
hardened skin. It is also helpful to
test with meter at on table.
Choose nger for test : ONLY USE
FINGERS YOU KNOW BLEED WELL.
You can use the sides or tip of nger.
Avoid calluses and ngernails.
Increase circulation: Prepare
ngertip for lancing by squeezing
several times until it’s warm and
reddish. COLD FINGERS SLOW
BLOOD FLOW.

Test Your Blood
TURN ON METER by pressing
power button under display.
IMPORTANT: DO NOT PLACE
FINGER ON TEST PORT until
meter is ready.
WAIT for the image of the nger on
the test port to appear
METER IS READY
Power
Button

IMPORTANT: At the end of the
countdown, you will be lanced.
DO NOT LIFT FINGER until
meter displays an up arrow
Make sure you PREPARE FINGER.
PRESS FINGER DOWN on test port
to be lanced and a 3-2-1 countdown
will begin
HOLD FINGER IN PLACE while blood
is collected.
LIFT FINGER when you see this.
Blood has been collected.
HOLD FINGER DOWN
OK to remove
your nger

POGO® Automatic™
Blood Glucose Monitoring System
Quick Start Guide
Press. Test. GO.
Simply press nger
here for easy,
One-Step™ testing.
3500 West Warren Avenue, Fremont, CA 94538
1-855-IMI-POGO (464-7646) www.pressPOGO.com
© 2019 Intuity Medical, Inc. All Rights Reserved.
Printed in the U.S.A. ART-02964 Rev 1
When the meter displays these
pictures, you should li your nger
and squeeze to get more blood.
You have 90 seconds to nish the
test. You will not be relanced during
this step.
REMOVE FINGER from test port.
GENTLY SQUEEZE to form a blood
droplet.
CENTER DROPLET over hole. Try not
to smear on test port.
PRESS ALL THE WAY DOWN into
cartridge.
You may need to REPEAT until you
see on screen.
YOU MUST START A NEW TEST if either an E-4
or NO message appear on screen, or you have
no wound.
Add More Blood (if needed)

Get Results
Your result will appear aer a
4-second countdown.
TURN OFF METER or allow to turn o
aer 30 seconds.
Quick graph
A color bar shown above the result indicates whether
your result is in or out of your target range
See Owner’s Manual for More Information
70
180
In RangeOut of Range
(Low)
Out of Range
(High)
126
mg/dL
70
180
2:15 PM
2/10/2019
9

Breakfast
Before Aer
Lunch Dinner Fasting
NOTE: To understand the eects that meals have
on your blood glucose, it is important to test
in “pairs” — 1 hour before and 2 hours aer you
eat. The American Diabetes Association (ADA)
also recommends testing prior to exercise and
bedtime or when hypoglycemia is suspected.
Aer a test, the meter displays a glucose result with a
blinking pre- or post-meal symbol.
If you CHOOSE NOT TO MARK your result:
• You are done. Turn o meter or allow it to turn o
automatically.
If you CHOOSE TO MARK your result:
• Press the scroll buttons until the ( )
marking dot appears before or aer the
appropriate meal symbol.
• To conrm, turn o meter or allow it to turn o
automatically.
Meal Marking (Optional)

No Blood Seen:
See Prepare Finger and repeat test.
Check Cartridge
Remove and re-insert cartridge.
DO NOT put nger on test port until
appears.
Not Enough Blood:
See Prepare Finger and repeat test.
No Cartridge
Open door and insert new cartridge.
Meter Error:
• Remove and re-insert batteries.
• Remove and re-insert test cartridge.
• Try testing with a new cartridge
Refer to your Owner’s Manual for more
information.
This is a list of common meter errors or
alerts and what to do when they occur.
CC
E-3
NO
E-4
2:15 PM
02/10/2019
10
Key Display Messages

POGO® Automatic™
Blood Glucose Monitoring System
Quick Start Guide
Press. Test. GO.
Simply press nger
here for easy,
One-Step™ testing.
To view your glucose results and health trend information
in the Patterns®Personal Wellness application, you must
rst pair the POGO meter with your smartphone.
Patterns® Personal Wellness System — View and securely
share your data, spot trends, and receive important alerts.
Available via the web and for download at the Apple and
Android app store. Visit www.patternsforpogo.com
How to pair
Step 1:Push thebutton for 4 seconds
Step 2:Enter the 6-digit code shown on the meter into
your smartphone when prompted
Step 3:Press “Pair” on phone to conrm. Your POGO
meter and phone should now be connected for automatic
transfer of your results
For Bluetooth pairing help, consult
your POGO Automatic Owner’s Manual.
Hold button
down for code
Enter code
into Phone
Conrm “Pair” to
complete pairing
Pair POGO With Your Phone

POGO® Automatic™
Blood Glucose Monitoring System
Quick Start Guide
Press. Test. GO.
Simply press nger
here for easy,
One-Step™ testing.
Important Warnings and Limitations of the POGO Automatic System:
• POGO meters and test cartridges are for single patient use only. Do not share
them with anyone, including other family members! Do not use on multiple
patients!
• All POGO testing supplies are considered biohazardous and can potentially
transmit infectious diseases, even aer you have performed cleaning and
disinfection. Wash hands with soap and water immediately aer use.
• Please refer to your POGO Automatic Blood Glucose Monitoring System Owner’s
Manual for complete cleaning and disinfection instructions.
Interfering Substance Information:
• If you have certain conditions that may cause your blood level of uric acid to rise,
such as gout or kidney disease (>9 mg/dL uric acid) then your blood glucose
results may be inaccurate. If you are unsure, then ask your doctor.
• If you are taking acetmaminophen containing drugs (e.g. Tylenol, certain cold
and u remedies, etc.) in excess of the recommended levels (>20 mg/dL) then you
may get inaccurate results with this system. If you are unsure, then ask
your doctor.
• If you are taking vitamin C (ascorbic acid) in excess of the recommended levels
(>3 mg/dL) then your glucose results may be inaccurate with this system. If you
are unsure, then ask your doctor.
The marks PATTERNS, POGO, POGO AUTOMATIC, and INTUITY MEDICAL are
registered trademarks of Intuity Medical, Inc. in the U.S., and registered and
unregistered marks in other countries.
The Bluetooth word mark and logos are registered trademarks owned by Bluetooth
SIG, Inc., and any use of such marks by Intuity Medical, Inc. is under license. APPLE
logo, APP STORE are trademarks of Apple, Inc. GOOGLE PLAY is a trademark of
Google Inc.
3500 West Warren Avenue, Fremont, CA 94538
1-855-IMI-POGO (464-7646) www.pressPOGO.com
© 2019 Intuity Medical, Inc. All Rights Reserved.
Printed in the U.S.A. ART-02964 Rev 02
For 24-hour Customer Service, 7 days a week, call
1-855-IMI-POGO (464-7646) www.presspogo.com
Other manuals for Automatic
2
Table of contents
Other Pogo Blood Glucose Meter manuals
Popular Blood Glucose Meter manuals by other brands

EPS Bio Technology
EPS Bio Technology smartLAB sprint nG user manual

A.MENARINI
A.MENARINI GlucoMen Day CGM user guide

Kinetik Wellbeing
Kinetik Wellbeing BG-710 instruction manual

Bayer HealthCare
Bayer HealthCare ESPRIT user guide

Accu-Chek
Accu-Chek Performa Connect Getting started guide

Accu-Chek
Accu-Chek Aviva manual

Dario
Dario Smart Meter user guide

Infopia
Infopia Element Lite Instructions for use

Bayer HealthCare
Bayer HealthCare Ascensia DEX2 Quick test guide

MHC Medical Products
MHC Medical Products Easy Touch Quick reference guide

Arkray
Arkray Glucocard Vital User instruction manual

BIONIME
BIONIME Rightest GS260 manual