Positron G1002-C User manual

G.hn to Gigabit Ethernet Bridge
Quick Installation Guide
G1002-C

G1002-C Quick Installation Guide
Positron Access Solutions 2 Document 180-0219-001 R01
Publication Information
©2021 Positron Access Solutions
G1002-C Quick Installation Guide
Publication date: December 2021
Printed in Canada
Published By
Positron Access Solutions
5101 Buchan Street, Suite 220
Montreal, Quebec, Canada
H4P 2R9
Telephone US and Canada: 1-888-577-5254
International: +1-514-345-2220
Product names, other than Positron's, mentioned herein may be trademarks and/or registered trademarks
their respective companies.
Disclaimer Notice
Although Positron Access Solutions has made every effort to ensure the accuracy of the information
contained herein, this document is subject to change.

G1002-C Quick Installation Guide
Positron Access Solutions 3 Document 180-0219-001 R01
CONTENTS
.........................................................................................................................................4
About the G1002-C.........................................................................................................................4
Introduction........................................................................................................................4
G1002-C (COAX) Endpoint...............................................................................................5
G1002-C LED Definition....................................................................................................5
G1002-C Gigabit Ethernet Ports .......................................................................................6
Physical Mounting of the G1002-C Device .......................................................................6
.........................................................................................................................................8
Technical and Regulatory Specifications....................................................................................8
G1002-C Technical Specifications....................................................................................8
Regulatory Compliance.....................................................................................................9
.......................................................................................................................................12
Warranty and Customer Service ................................................................................................12

G1002-C Quick Installation Guide
Positron Access Solutions 4 Document 180-0219-001 R01
______________________________________
About the G1002-C
Introduction
The G1002-C G.hn to Ethernet Bridgecompletes the G.hn link (coax) with the G.hn
Access Multiplexer (GAM) and converts the G.hn interface to a standard Gigabit
Ethernet (RJ-45) interface. It is designed for indoor installation, usually inside the
subscriber premises and connects to a Residential Gateway (RG) or comparable
devices.
About G.hn
The ITU-T G.9960 G.hn Wave-2 standard leverages the existing telephone wiring
(UTP, CAT-3 or CAT-5/5e) or RG-6/RG-59 coax cabling to deliver a Gigabit
Internet service to each subscriber without the cost, complexity and delays
associated with in-building fiber installation. G.hn is an Access technology for
Operators looking to simplify their access network and backend infrastructure with
an Ethernet-like technology that is highly scalable without some of the inherent
complexity of DSL-related technologies. With G.hn, Operators deliver advanced
services such as Gigabit High Speed Residential Internet and 4K IPTV without the
high capital and operational expenses associated with a fiber retrofit. Each G.hn
subscriber port supports up to 1.7 Gbps of dynamically allocated bandwidth for
near symmetrical Gigabit services over the existing telephone wire or coaxial
cable.
Note: Read Chapter entitled “Safety and Warnings”before proceeding.

G1002-C Quick Installation Guide
Positron Access Solutions 5 Document 180-0219-001 R01
G1002-C (COAX) Endpoint
The G1002-C (coax) G.hn Bridge to Gigabit Ethernet comes with two (2) Gigabit
Ethernet port to connect the Residential Gateway (RG).
Figure 1: G1002-C Gigabit Ethernet Port and Status LEDs
The G1002-C comes with a built-in low-pass COAX filter to eliminate any noise
above CATV Channel 30 (258 MHz) to make sure there is no artefact from the
G.hn signal on the CATV channels Note: G.hn uses up to 200 MHz of spectrum
in the range of 5-200 MHz.
Figure 2: G1002-C port definition
G1002-C LED Definition
The G1002-C status LEDs are defined in the following table:
LED position
Description
G.hn (green)
ON indicates G.hn link up
OFF indicates G.hn link down
BLINKING indicates G.hn link speed less than 40 Mbps
PWR (green)
Indicates power on or off
STA (yellow)
Green indicates units is working
Yellow indicates unit is booting or being reset
Table 1: G1002-C LED Definition
G.hn Port (F-type)
12Vdc Jack
2 x Gigabit Ethernet (RJ-45)
G1002-C Status LEDs/

G1002-C Quick Installation Guide
Positron Access Solutions 6 Document 180-0219-001 R01
Figure 3: G1002-C LED definition
G1002-C Gigabit Ethernet Ports
The G1002-C incorporates two (2) RJ-45 Gigabit Ethernet ports. Please note that
port GE1 can be configured in VLAN Trunk mode (via the GAM) if required for your
application.
Physical Mounting of the G1002-C Device
You can optionally install (mount) the G1002-C enclosure on a wall or flat surface
as follows:
1. Select a proper mounting location where you can securely install mounting
screws (not supplied).
2. Use the G1002-C enclosure as a guide to determine where you need to install
the two (2) mounting screws.
3. Install the lower screw into the wall but do no tighten completely. Use a wall
plug if inserting the screws into a dry wall. Leave enough room to insert the
G1002-C enclosure (see step 4).
4. Insert the G1002-C slot (as per the figure 5 below) and slightly tighten the
lower screw to hold the G1002-C in place while you install the top screw.
5. Tighten both screws to hold the G1002-C securely in place but do not apply
too much torque to avoid damaging the screws or the wall mounting.
G1001 Status LED
G.hn Status LED
Power LED

G1002-C Quick Installation Guide
Positron Access Solutions 7 Document 180-0219-001 R01
Figure 4: Mounting holes to install G1001 device on a flat surface
Use two (2) screws #10 (5mm) to install the
G1002-C enclosure on a flat surface. If mounting
on a dry wall, use adequate wall plugs (not
supplied)

G1002-C Quick Installation Guide
Positron Access Solutions 8 Document 180-0219-001 R01
______________________________________
Technical and Regulatory Specifications
G1002-C Technical Specifications
Environmental Features
Dimensions
3.7” Width x 1.35” Height x 6.7” Depth / 95 mm W x 34.3 mm H x 169.5 mm D
Power
12 VDC / 1A power adapter (110-220VAC), draws less than 3W
Certification
CE Mark, FCC Part 15 Class B
Temperature
Operating: 0˚C to +40 ˚C / Storage: -25˚C to +80 ˚C
Operating Humidity
5% to 95% relative, non-condensing
G.hn Specification
G.hn Standards
G.hn Wave-2 Client, based on GigaWire Alliance specification and fully
compliant with the following ITU-T standards
•G.9960 Amendment 2 - System Architecture and PHY Layer
•G.9961 Data Link Layer
•G.9962 Management
•G.9964 PSD
Ease of Deployment
Support G.hn over coax (G1002-C)
Point-to-point and Point-
to-multipoint support
Supports Point-to-point or Point-to-multipoint operation (coax) for up to
16 G1002-C per G.hn port
Ease of Operation
Automatic firmware and configuration management via the Positron GAM
Encryption
AES-128 encryption with individual keys for each end-node under the control of
the Positron GAM acting as the Master Node
Modulation and
Frequency Band
Radio Band Notching function allows cohabitation with legacy Analog Cable TV
channels over coax
Bandwidth Management
Up to 1.7 Gbps with Dynamic Bandwidth Allocation to optimize throughput
based on nature of traffic flows with TDD Multiplexing for programmable
upstream / downstream ratio
Reliability and Resiliency
State of the art LDPC Forward Error Correction (FEC)

G1002-C Quick Installation Guide
Positron Access Solutions 9 Document 180-0219-001 R01
Regulatory Compliance
FCC Declaration of Conformance
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and;
(2) This device must accept any interference received, including interference that
may cause undesired operation. NOTE: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates—and
can radiate—radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If the equipment does not cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
•Reorient or relocate the receiving antenna
•Increase the separation between the equipment and the receiver
•Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Safety Information
The G1002-C is a highly sophisticated electronic device. To get the most out of it,
be sure to read the following text about product care, safety and efficient use.
•Treat the product with care, keep it in a clean and dust free environment.
•Do not expose the G1002-C to liquid, moisture or humidity.
•Do not expose the G1002-C to extreme high or low temperatures; refer to
the topic Environmental Conditions for more details.
•Do not expose the G1002-C to open flames.
•Do not drop, throw, or try to bend the product, since rough treatment could
damage it.
•Do not use this product near water, for example, near a bathtub, washbowl,
kitchen sink, laundry tub, in a wet basement, or near a swimming pool.

G1002-C Quick Installation Guide
Positron Access Solutions 10 Document 180-0219-001 R01
•Do not attempt to disassemble the G1002-C. The product does not contain
consumer-serviceable components. Only Certified Service Centers should
perform service.
•Do not use any accessories other than those approved by the manufacturer
or your service provider. Use of non-original or non-approved accessories
may result in loss of performance, damage to the product, fire, electric
shock or injury, and may violate regulations. The warranty does not cover
product failures resulting from use of non-original or non-approved
accessories.
Intended Use
Approved for use in an indoor location only
Power Supply
•Ensure that a suitable AC power outlet is located near the G1002-C and
easily accessible.
•Connect the power supply cord only to the AC power outlet that meets the
specifications marked on the AC power adapter and connect the DC
connector to the inlet of the G1002-C.
•Never alter the AC power cord. If necessary have the correct outlet installed
by a qualified electrician or call your service provider for assistance.
•To reduce risk of damage to the electric cord, remove it from the outlet by
holding onto the AC power adapter rather than the cord. Make sure to
position the cord such that it is not stepped on, tripped over or otherwise
subjected to damage or stress.
Declaration of Conformity
Hereby, the manufacturer declares that this product (G1002-C) is in conformity
with the requirements and other relevant provisions of the following European
directives for the CE mark:
•1999/5/EC: R&TTE Directive
•2006/95/EC: Low Voltage Directive
•2004/108/EC: Electromagnetic Compatibility Directive (EMC)
The manufacturer declares that this product (G1002-C) is in conformity with the
requirements and other relevant provisions of the following Canadian standards:

G1002-C Quick Installation Guide
Positron Access Solutions 11 Document 180-0219-001 R01
•CAN ICES-3 (B)/NMB-3(B)
Environmental Conditions
Maximum environmental values during use:
•Temperature: 0°C to +40°C (32° to 104° F)
•Humidity: 5% to 95% RH, non-condensing
RoHS Compliance
This G1002-C meets the requirements detailed in the European RoHS Directive
(2002/95/EC).
WEEE Directive
Requirements according to WEEE directive (2002/96/EC)
•Disposal of old electrical and electronic equipment (Applicable in the
European countries with separate collection systems).
•This symbol on the product indicates that this product shall not be
treated as household waste. Instead, it shall be handed over to the
applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will
prevent potential negative consequences for the environment and
human health, which could otherwise be caused by inappropriate waste
handling of this product. The recycling of materials will help to conserve
natural resources.

G1002-C Quick Installation Guide
Positron Access Solutions 12 Document 180-0219-001 R01
______________________________________
Warranty and Customer Service
Positron Access Solutions will replace or repair this product within the warranty
period if it does not meet its published specifications or fails while in service.
Warranty information can be found in your Positron Access customer web portal:
http://www.positronaccess.com/Portal.php
Positron Access Solutions Sales Pricing/Availability and Technical Support
US and Canada: 1-888-577-5254
International: +1-514-345-2220
Repair and Return Address
Contact Customer Service prior to returning equipment to Positron.
Telephone US and Canada: 1-888-577-5254 option 6
International: +1-514-345-2220 option 6
Other manuals for G1002-C
2
Table of contents
Other Positron Network Router manuals
Popular Network Router manuals by other brands

Luxul
Luxul XBR-2300 Quick install guide

RCA
RCA 25801 user guide

NetComm
NetComm NB4 Specifications

Linksys
Linksys WRT320N - Wireless-N Gigabit Router Wireless user guide

D-Link
D-Link DWC-1000 Quick installation guide

Planet Networking & Communication
Planet Networking & Communication MGSW-28240F user manual