•Adjust the hold time using the time control on the side of the sensor to 10 seconds.
•Switch on the power; the sensor and its connected lamp will have no signal to start with.
After Warm-up 30sec, the sensor will work. If the sensor receives the induction signal, the lamp
will turn on. When there is no induction signal, the load should stop working within 10sec
±3sec and the lamp would turn off.
•Turn LUX control clockwise to the minimum (3). If the ambient light ismore than 3LUX, the sensor
will not be activated. If the ambient light is less than 3LUX (night time), the sensor will be
activated.
Note if testing during daylight, turn the lux control clockwise to the sun setting.
•The load does not work:
a. Please check ifthe connection of power source and load is correct.
b. Please check ifthe load is ok.
c. Please check ifthe settings of on the sensor correspond to ambient light.
•The sensitivity ispoor:
a. Please check ifthere is any obstruction in front of the detector that would cause the
sensor not to receive a signal.
b. Please check ifthe ambient temperature is too high.
c. Please check ifthe induction signal source isinthe detection field.
d. Please check if the installation height corresponds to the height recommended in
the instruction leaflet.
•The sensor won’t switch off the load automatically:
a. Please check ifthere is continual signal in the detection field.
b. Please check ifthe time delay is set to the maximum position.
Height of installation: 1.8-2.5m Detection Distance: Max.12m
Sensor Information
Testing the Sensor
Troubleshooting
1800 909 306 nedlandsgroup.com.au
[email protected]
Certainty at The Speed of Light
INSTALLATION
MANUAL
INFRARED MOTION
SENSOR
MS-12M-180
MS-12M-180 Infrared motion sensor
The sensor has great detection sensitivity via integrated circuitry. It utilizes the infrared energy from
humans as the control-signal source.
Power Source: 220-240V/AC
Power Frequency: 50/60Hz
Ambient Light: <3-2000LUX (adjustable)
Time Delay: Min.10sec±3sec
Detection Range: 180°
Detection Distance: 12m max (<24℃)
Working Temperature: -20~+40℃
Working Humidity: <93%RH
Max.15min±2min
Rated Load: Max.1200W
300W
Power Consumption: approx 0.5W
Installation Height: 1.8-2.5m
Detection Moving Speed: 0.6-1.5m/s
As the detector responds to changes in temperature, avoid the following situations:
•Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
•Avoid mounting the detector near heat sources, such as heating vents, air conditioning units and
light etc.
•Avoid pointing the detector towards objects that may move in the wind, such as curtains and tall
plants etc.
Introduction
Installation Recommendation
Warning. Danger of death through electric shock!
Must be installed by professional electrician,
Disconnect power source.
Cover or shield any adjacent live components.
Ensure device cannot be switched on.
Check power supply isdisconnected.
•Loosen the screw at the bottom of the sensor and remove the cover (refer to the figure1).
•Pass the power wire through the hole with gasket in the bottom. Connect the power wire into
the terminal as per the wiring diagram.
•Fix the wall plate to the installation surface. (refer to the figure2).
•Install back the sensor on the wall place, tighten the screw and test it.
Figure1 Figure2
Installation
Connection Wire Diagram
Specifications

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.