PR electronics PReasy 4131 User manual

pending
Galvanic isolators for analogue and digital
signals as well as HART®signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume, weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Interfaces for analogue and digital signals
as well as HART®signals between sensors / I/P convert-
ers / frequency signals and control systems in Ex zone 0,
1 & 2. Feature options such as mathematical functions
and 2 wire transmitter interfaces.
Flexible motherboard solutions for sys-
tem 5000 modules. Our backplane range features flexible
8 and 16 module solutions with configuration via PReplan
8470 – a PC program with drop-down menus.
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specific to universal transmitters.
Isolation
Temperature
Ex barriers
Displays
Backplane
DK
UK
FR
DE
Side 1
Page 25
Page 49
Seite 73
SIGNALS THE BEST
4131
Universal
Trip Amplifier
No. 4131V100-IN (0525)
From ser. no. 050430001

UNIVERSAL GRÆNSEKONTAKT
PReasy 4131
INDHOLDSFORTEGNELSE
Advarsler ............................................................................ 2
Sikkerhedsregler................................................................. 3
Overensstemmelseserklæring............................................ 5
Afmontering af SYSTEM 4000 ........................................... 6
Anvendelse......................................................................... 7
Teknisk karakteristik........................................................... 7
Montage / installation......................................................... 7
PR 4501 Display / programmeringsfront ........................... 8
Applikationer ...................................................................... 9
Bestillingsnumre................................................................. 10
Elektriske specifikationer ................................................... 10
Displayvisning på 4501 af følerfejlsdetektering og
indgangssignal uden for område: .................................. 13
Tilslutninger ........................................................................ 15
Blokdiagram ....................................................................... 16
Programmering / betjening af trykknapper........................ 17
Rutediagram....................................................................... 18
Rutediagram, avancerede indstillinger (ADV.SET).............. 22
Rullende hjælpetekster i displaylinie 3............................... 23
Grafisk afbildning af relæfunktionen setpunkt ................... 24
Grafisk afbildning af relæfunktionen vindue ...................... 24
1

SIGNATURFORKLARING
Trekant med udråbstegn: Advarsel / krav. Hændelser der kan føre til livs-
truende situationer.
CE-mærket er det synlige tegn på modulets overensstemmelse med
EU-direktivernes krav.
Dobbelt isolation er symbolet for, at modulet overholder ekstra krav til
isolation.
SIKKERHEDSREGLER
DEFINITIONER:
Farlige spændinger er defineret som områderne: 75...1500 Volt DC og
50...1000 Volt AC.
Teknikere er kvalificerede personer, som er uddannet eller oplært til at kunne
udføre installation, betjening eller evt. fejlfinding både teknisk og sikkerheds-
mæssigt forsvarligt.
Operatører er personer, som under normal drift med produktet skal indstille og
betjene produktets trykknapper eller potentiometre, og som er gjort bekendt
med indholdet af denne manual.
MODTAGELSE OG UDPAKNING:
Udpak modulet uden at beskadige dette, og sørg for, at manualen altid følger
modulet og er tilgængelig. Indpakningen bør følge modulet, indtil dette er mon-
teret på blivende plads.
Kontrollér ved modtagelsen, at modultypen svarer til den bestilte.
MILJØFORHOLD:
Undgå direkte sollys, kraftigt støv eller varme, mekaniske rystelser og stød, og
udsæt ikke modulet for regn eller kraftig fugt. Om nødvendigt skal opvarmning,
ud over de opgivne grænser for omgivelsestemperatur, forhindres ved hjælp af
ventilation.
Alle moduler hører til Installationskategori II, Forureningsgrad 1 og Isolations-
klasse II.
32
ADVARSEL
Dette modul er beregnet for tilslutning til livsfarlige elektriske
spændinger. Hvis denne advarsel ignoreres, kan det føre til
alvorlig legemsbeskadigelse eller mekanisk ødelæggelse.
For at undgå faren for elektriske stød og brand skal manualens
sikkerhedsregler overholdes, og vejledningerne skal følges.
Specifikationerne må ikke overskrides, og modulet må kun
benyttes som beskrevet i det følgende.
Manualen skal studeres omhyggeligt, før modulet tages i brug.
Kun kvalificeret personale (teknikere) må installere dette modul.
Hvis modulet ikke benyttes som beskrevet i denne manual, så
forringes modulets beskyttelsesforanstaltninger.
ADVARSEL
For at overholde sikkerhedsafstande må der ikke tilsluttes både
farlig og ikke-farlig spænding på modulets relækontakter.
SYSTEM 4000 skal monteres på DIN-skinne efter DIN 46277.
ADVARSEL
Der må ikke tilsluttes farlig spænding til modulet, før dette
er fastmonteret, og følgende operationer bør kun udføres på
modulet i spændingsløs tilstand og under ESD-sikre forhold:
Installation, ledningsmontage og -demontage.
Fejlfinding på modulet.
Reparation af modulet og udskiftning af sikringer må kun
foretages af PR electronics A/S.
FARLIG
SPÆNDING
INSTAL-
LATION
GENERELT

OVERENSSTEMMELSESERKLÆRING
Som producent erklærer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hermed at følgende produkt:
Type: 4131
Navn: Universal grænsekontakt
er i overensstemmelse med følgende direktiver og standarder:
EMC-direktivet 2004/108/EF og senere tilføjelser
EN 61326
Denne erklæring er udgivet i overensstemmelse med EMC-direktivets paragraf
10, stk. 1. For specifikation af det acceptable EMC-niveau henvises til modu-
lets elektriske specifikationer.
Lavspændingsdirektivet 73/23/EØF og senere tilføjelser
EN 61010-1
Rønde, 29. juni 2005 Peter Rasmussen
Producentens underskrift
5
INSTALLATION:
Modulet må kun tilsluttes af teknikere, som er bekendte med de tekniske
udtryk, advarsler og instruktioner i manualen, og som vil følge disse.
Hvis der er tvivl om modulets rette håndtering, skal der rettes henvendelse til
den lokale forhandler eller alternativt direkte til:
PR electronics A/S, Lerbakken 10, 8410 Rønde,
Danmark, tlf: +45 86 37 26 77.
Installation og tilslutning af modulet skal følge landets gældende regler for
installation af elektrisk materiel bl.a. med hensyn til ledningstværsnit, for-sikring
og placering.
Beskrivelse af indgang / udgang og forsyningsforbindelser findes på blokdia-
grammet og sideskiltet.
For moduler, som er permanent tilsluttet farlig spænding, gælder:
For-sikringens maksimale størrelse er 10 A, og den skal sammen med
en afbryder placeres let tilgængeligt og tæt ved modulet. Afbryderen
skal mærkes således, at der ikke er tvivl om, at den afbryder spændin-
gen til modulet.
KALIBRERING OG JUSTERING:
Under kalibrering og justering skal måling og tilslutning af eksterne spændinger
udføres i henhold til denne manual, og teknikeren skal benytte sikkerhedsmæs-
sigt korrekte værktøjer og instrumenter.
BETJENING UNDER NORMAL DRIFT:
Operatører må kun indstille eller betjene modulerne, når disse er fast installeret
på forsvarlig måde i tavler el. lignende, så betjeningen ikke medfører fare for liv
eller materiel. Dvs., at der ikke er berøringsfare, og at modulet er placeret, så
det er let at betjene.
RENGØRING:
Modulet må, i spændingsløs tilstand, rengøres med en klud let fugtet med
destilleret vand eller sprit.
ANSVAR:
I det omfang instruktionerne i denne manual ikke er nøje overholdt, vil kunden
ikke kunne rette noget krav, som ellers måtte eksistere i henhold til den indgå-
ede salgsaftale, mod PR electronics A/S.
4

UNIVERSAL GRÆNSEKONTAKT
PReasy 4131
• Grænsekontakt med indgang for RTD, TC, Ohm,
potentiometer, mA og V
• 2 justerbare alarmgrænser
• Programmerbar via displayfront
• 2 relæudgange
• Universel forsyning med AC eller DC
Anvendelse:
• Styring af procesforløb med 2 sæt potentialefri relækontakter, som kan konfi-
gureres til enhver tænkelig funktion.øl
• Grænsekontakt med vinduesfunktion, så relæet kan skifte tilstand inden for et
lavt og et højt setpunkt på indgangsspannet.
• Avanceret følerfejlsovervågning hvor det ene relæ holder tilstanden umid-
delbart før, følerfejlen opstod, så processen kan køre videre. Det andet relæ
bruges til følerfejlsalarm, så føleren hurtigst muligt kan udskiftes.
• 4131 er konstrueret med et højt sikkerhedsniveau, så den er anvendelig i SIL
2 installationer.
Teknisk karakteristik:
• Med påmonteret display / programmeringsfront kan alle driftsparametre tilpas-
ses enhver applikation. Elektroniske hardwareswitche betyder, at modulet
ikke skal åbnes for indstilling af dipswitche.
• Grøn / rød LED i front, der indikerer normal drift og funktionsfejl. 2 gule LEDs
indikerer, hvilket relæ der er trukket.
• Der er løbende sikkerhedscheck af gemte data.
• 3-port 2,3 kVAC galvanisk isolation.
Montage / installation:
• Monteres på DIN-skinne, vertikalt eller horisontalt. Modulerne kan monteres
uden indbyrdes afstand, hvilket svarer til 42 moduler pr. meter.
7
AFMONTERING AF SYSTEM 4000
Husk først at demontere tilslutningsklemmerne med farlig spænding.
Billede 1:
Modulet frigøres fra DIN-skinnen ved
at løfte i den nederste lås.
6

PR 4501 DISPLAY / PROGRAMMERINGSFRONT
Anvendelse:
• Kommunikationsinterface til ændring af driftsparametre i 4131.
• Kan flyttes fra en 4131 til en anden 4131 og downloade den første grænse-
kontakts opsætning til efterfølgende grænsekontakter.
• Som fastmonteret display til visualisering af procesdata og status.
Teknisk karakteristik:
• Fire liniers LCD-display; 1 linie med højden 5,57 mm, 2 linier med højden 3,33
mm, og 1 linie med faste ikoner.
• Programmeringsadgang kan forhindres ved indkodning af et password.
Passwordet gemmes i transmitteren, så sikkerheden mod uønskede ændrin-
ger er så høj som muligt.
Montage / installation:
• Klikkes på fronten af 4131.
98
Applikationer
Indgangssignaler:
Strøm
Spæn-
ding
Potenti-
ometer RTD og lin.R TC
Forbindelse, ledere
Udgangssignaler:
Forsyning:
21,6...253 VAC
eller
19,2...300 VDC
33
32
31
+
-
+
-
44
43
42
41
Relæer
24
23
22
21

Hjælpespændinger:
2-trådsforsyning (klemme 44...43) .............. 25...16 VDC / 0...20 mA
Ledningskvadrat (max.)............................... 1 x 2,5 mm2flerkoret ledning
Klemskruetilspændingsmoment.................. 0,5 Nm
Relativ luftfugtighed .................................... < 95% RH (ikke kond.)
Mål, uden displayfront (HxBxD) .................. 109 x 23,5 x 104 mm
Mål, med displayfront (HxBxD) ................... 109 x 23,5 x 116 mm
Tæthedsgrad (kabinet / klemmer)............... IP50 / IP20
Vægt............................................................ 170 g
RTD-, lineær modstands- og potentiometerindgang:
Kabelmodstand pr. leder, (max.) ................. 50 Ω
Følerstrøm, RTD.......................................... Nom. 0,2 mA
11
BESTILLINGSNUMRE:
4131 = Universal grænsekontakt
4501 = Display / programmeringsfront
Elektriske specifikationer:
Specifikationsområde:
-20 til +60°C
Fælles specifikationer:
Forsyningsspænding, universel................... 24...230 VAC ±10%
50...60 Hz
24...250 VDC ±20%
Max. forbrug................................................ ≤2,5 W
Sikring ......................................................... 400 mA T / 250 VAC
Isolationsspænding, test / drift ................... 2,3 kVAC / 250 VAC
Kommunikationsinterface............................ Programmeringsfront 4501
Signal- / støjforhold..................................... Min. 60 dB (0...100 kHz)
Reaktionstid (0...90%, 100...10%):
Temperaturindgang.................................
≤ 1 s
mA- / V-indgang...................................... ≤ 400 ms
Kalibreringstemperatur................................ 20...28°C
Nøjagtighed, størst af generelle og basisværdier:
10
EMC-immunitetspåvirkning................................. < ±0,5% af span
Udvidet EMC-immunitet:
NAMUR NE 21, A-kriterium, gniststøj................. < ±1% af span
Basisværdier
Indgangstype Basis-
nøjagtighed Temperatur-
koefficient
mA ≤±4 µA ≤±0,4 µA / °C
Volt ≤±20 µV ≤±2 µV / °C
Pt100 ≤±0,2°C ≤±0,01°C / °C
Lin.R ≤±0,1 Ω≤±10mΩ/ °C
Potentiometer ≤±0,1 Ω≤±0,01 Ω/ °C
TC-type:
E, J, K, L, N, T, U ≤±1°C ≤±0,05°C / °C
TC-type: B, R, S,
W3, W5, LR ≤±2°C ≤±0,2°C / °C
Generelle værdier
Indgangstype Absolut
nøjagtighed Temperatur-
koefficient
Alle ≤±0,1% af span ≤±0,01% af span / °C
Indgangs-
type Min.
værdi Max.
værdi Norm
Pt100
Ni100
Lin. R
Potentiometer
-200°C
-60°C
0 Ω
10 Ω
+850°C
+250°C
10000 Ω
100 kΩ
IEC60751
DIN 43760
-
-

Relæudgange:
Max. spænding ........................................... 250 VRMS
Max. strøm .................................................. 2 A / AC eller 1 A / DC
Max. AC-effekt ............................................ 500 VA
Følerfejlsdetektering.................................... Bryde / Slutte / Hold
Overholdte myndighedskrav: Standard:
EMC 2004/108/EF:
Emission og immunitet .......... EN 61326
LVD 73/23/EØF............................................ EN 61010-1
* UL, Standard for Safety............................ UL 508
* Godkendelse ansøgt, forventes efterår 2005
Af span = af det aktuelt valgte område
Displayvisning på 4501 af følerfejlsdetektering og
indgangssignal uden for område:
13
Virkning af følerkabelmodstand
(3- / 4-leder), RTD ....................................... < 0,002 Ω/ Ω
Følerfejlsdetektering, RTD........................... Ja
Kortslutningsdetektering, RTD .................... < 15 Ω
TC-indgang:
Koldt loddestedskomp. (CJC)..................... < ±1,0 °C
Følerfejlsdetektering.................................... Ja
Følerfejlsstrøm:
under detektering.................................... Nom. 2 µA
ellers........................................................ 0 µA
Strømindgang:
Måleområde ................................................ -1...25 mA
Programmerbare måleområder ................... 0...20 og 4...20 mA
Indgangsmodstand ..................................... nom. 20 Ω+ PTC 50 Ω
Spændingsindgang:
Måleområde ................................................ -20 mV...12 VDC
Programmerbare måleområder ................... 0...1 / 0,2...1 / 0...5 / 1...5 /
0...10 og 2...10 VDC
Indgangsmodstand ..................................... Nom. 10 MΩ
12
Type Min.
værdi Max.
værdi Norm
B
E
J
K
L
N
R
S
T
U
W3
W5
LR
+400°C
-100°C
-100°C
-180°C
-200°C
-180°C
-50°C
-50°C
-200°C
-200°C
0°C
0°C
-200°C
+1820°C
+1000°C
+1200°C
+1372°C
+900°C
+1300°C
+1760°C
+1760°C
+400°C
+600°C
+2300°C
+2300°C
+800°C
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
ASTM E988-90
ASTM E988-90
GOST 3044-84
Følerfejlscheck:
Modul: Konfiguration Følerfejlsdetektering:
4131 R1, ERR.ACT=NONE - R2, ERR.ACT=NONE, OFF
Ellers: ON

14 15
TILSLUTNINGER:
Uden for område visning (IN.LO, IN.HI):
Ved overskridelse af A/D-konverterens eller polynomiets gyldige område
Indgang Område Visning Grænse
VOLT
0...1 V / 0,2...1 V IN.LO < -25 mV
IN.HI > 1,2 V
0...10 V / 2...10 V IN.LO < -25 mV
IN.HI > 12 V
CURR 0...20 mA / 4...20 mA IN.LO < -1,05 mA
IN.HI > 25,05 mA
LIN.R
0...800 ΩIN.LO < -10 Ω
IN.HI > 1075 Ω
0...10 kΩIN.LO < -10 Ω
IN.HI < 110 kΩ
POTM - IN.LO < -0,5 %
IN.HI > 100,5 %
TEMP TC / RTD IN.LO < temperaturområde -2°C
IN.HI > temperaturområde +2°C
Følerfejlsdetektering (SE.BR, SE.SH):
Indgang Område Visning Grænse
CURR Strømsløjfebrud (4..20 mA) SE.BR <= 3,6 mA; > = 21 mA
POTM Alle SE.BR > ca. 126 kΩ
LIN.R 0...800 ΩSE.BR > ca. 875 Ω
0...10 kΩSE.BR > ca. 11 kΩ
TEMP
TC SE.BR > ca. 750 kΩ/ (1,25 V)
Pt100 2-leder SE.BR > ca. 15 kΩ
SE.SH < ca. 15 Ω
Pt100 3-leder SE.BR > ca. 15 kΩ
SE.SH < ca. 15 Ω
Pt100 4-leder SE.BR > ca. 15 kΩ
SE.SH < ca. 15 Ω
Display under min.- / over max.-visning (-1999, 9999):
Indgang Område Visning Grænse
Alle Alle -1999 Displayværdi <-1999
9999 Displayværdi >9999
! Alle fejlvisninger i display blinker 1 gang pr. sekund samt suppleres med tilhørende hjælpetekst.
Indgange:
Udgange:
Forsyning:
31 32 33
Relæer
21 22 24
23
R1 R2
RTD, 3- / 4-leder
41 42 44
43
RTD, 2-leder
42 44
43
41
Modstand, 2-leder
41 42 44
43
TC
41 42 44
43
+
-
Strøm
+
-
41 42 44
43
2-Trådstransmitter
+
-Tx
41 42 44
43
Modstand,
3- / 4-leder
41 42 44
43
Potentiometer
41 42 44
43
Spænding
+
-
41 42 44
43
Visning ved hardwarefejl
Fejlsøgning Visning Årsag
Test af intern kommunikation uC / ADC HW.ER Permanent fejl i ADC
Test af intern CJC-sensor CJ.ER CJC-sensor defekt
Checksum test af den aktuelle konfiguration i RAM RA.ER Fejl i RAM
Checksum test af den aktuelle konfiguration i FLASH FL.ER Fejl i FLASH
Check om gemt konfiguration i 4501 passer med modul TY.ER Konfiguration er ikke 4131
Test af 4501 / 4131 kommunikation CO.ER Fejl i stikforbindelse

PROGRAMMERING /
BETJENING AF TRYKKNAPPER
Dokumentation til rutediagram.
Generelt:
Når du skal konfigurere 4131, bliver du guidet igennem samtlige parametre og
kan vælge netop de indstillinger, der passer til applikationen. Til hver menu
findes en rullende hjælpetekst, som vises i displaylinie 3.
Konfigurationen udføres ved hjælp af de 3 taster:
forøger talværdien eller vælger næste parameter
formindsker talværdien eller vælger forrige parameter
accepterer valget og går til næste menu
Når konfigurationen er gennemført, returneres til normaltilstand 1.0.
Tryk og hold tasten nede for at gå til forrige menu eller normaltilstand (1.0)
uden at gemme de ændrede tal eller parametre.
Hvis ingen taster har været aktiveret i 1 minut, returnerer displayet til normaltil-
stand (1.0) uden at gemme de ændrede tal eller parametre.
Uddybende forklaringer:
Hurtig setpunktsindstilling og test af relæer: Med disse menuer kan du fore-
tage hurtig setpunktsændring og relætest, når menuen FastSet er aktiveret.
Funktionen gælder kun, når relæerne fungerer som setpunktsfunktion og
styres af et setpunkt.
Ved at trykke på og samtidigt aktiveres en relætest, og relæet skifter til-
stand.
Ved kort tryk på gemmes setpunktsændringen.
Holdes tasten nede i mere end 1 sekund, returneres til normaltilstand (1.0)
uden at gemme setpunktsændringen.
Passwordbeskyttelse: Programmeringsadgang kan forhindres ved indkodning
af et password. Passwordet gemmes i grænsekontakten, så sikkerheden
mod uønskede ændringer er så høj som muligt. Default password 2008 giver
adgang til alle programmeringsmenuer.
1716
24
23
22
21
CPU
CPU
EEPROM
A / D
33
31
PTC
CJC
0.2 mA
43
44
42
41
432
Safety
10 Ω
MUX
+
-
+
-
+
-
12
5!+5$
IJFK
Potentiometer
2-trådstransmitter
Spænding
Strøm
RTD og lin.R,
leders
forbindelse
Forsyning
Forsyning
24...230 VAC eller
24...250 VDC
TC
Relæ 2
Relæ 2
Relæ 1
Relæ 1
Grøn
Rød
Gul
Gul
4131
BLOKDIAGRAM:

1918
Power up
/!226
3UQ
-.
!"52$3
3UQ
-.
8$2
5.+3
(-38/$
3UQ
5.+3
#4
+(-
/.3,
3$,/
$+!8
3UQ
$+!8
3UQ
Hurtig setpunktsindstilling
og test af relæer
Forøgelse af setpunkt
Formindskelse af setpunkt
Gem og forlad menuen
og samtidig = relæ skifter tilstand
5 !-&$
3UQ
#4
(-38/$
3UQ
( !-&$
3UQ
+(-
(-38/$
3UQ
6
#.--$#
3UQ
6
6
6
/.3,
(-38/$
3UQ
3$,/
(-38/$
3UQ
^#
4-(3
3UQ
^#
^%
3UQ
3UQ
/Q
2$-2.
3UQ
/Q
-(
3#
8$2
!"52$3
3UQ
-F
2$-2.
3UQ
3#
2$-2.
3UQ
/Q38/$
3UQ
6
#.--$#
3UQ
6
6
6
-F38/$
3UQ
6
#.--$#
3UQ
6
6
6
3#*
3#38/$
3UQ
3#\3#$3#)3#*
3#+3#-3# 3#2
3#33#43#63#6
3#+O
"(2/+.
3UQ
"$#/
3UQ
4-(3
3UQ
J!
IJFK
HDE
RKFQP
"(2/'(
3UQ
"(2/
$+4-
3UQ
"(2/
/$ #
-.
#.-3
3UQ
-.
-#
2$3/
3UQ
(-#
!#3"(
3UQ
(-#
"$#
'823
3UQ
2$3/
%4-#
3UQ
2$3/
6(-"
$
/.6
.%%
.(6
#.-3
3UQ
.(6
#(6
2$3/+.
3UQ
2$3/'(
3UQ
'823
3UQ
6(-"
%4-#
3UQ
./$-
$ !#3
3UQ
#+.2
./$-
$
%4-#
3UQ
/.6
%4-#
3UQ
.%%
%4-#
3UQ
Fortsættes næste side
1.0
1.2
1.0 = Normaltilstand
1.1 = Kun hvis beskyttet
med password
1.2 = Kun hvis FastSet
er aktiveret, og re-
læfunktionen er
setpunkt
1.3 = Gælder ikke for
indgangssignaler:
0...20 mA og
spænding
Rutediagram
Hvis ingen taster har været aktiveret i 1 minut, returnerer displayet til nor-
maltilstanden 1.0 uden at gemme eventuelle konfigurationsændringer.
Forøgelse af værdi / vælg næste parameter
Formindskelse af værdi / vælg forrige parameter
Accepter valget og gå til næste menu
Holde går til forrige menu / returnerer til 1.0 uden at gemme
Fortsættes på siden
Rutediagram ADV.SET
1.1
1.3

20 21
.-"$+
3UQ
-.-$
$ !#3
3UQ
'.+"
#+.2
./$-
-.-$
.%%"$+
3UQ
.-"$+
3UQ
-.-$
$ !#3
3UQ
'.+"
#+.2
./$-
-.-$
.%%"$+
3UQ
-.
#.-3
3UQ
-.
-#
2$3/
3UQ
(-#
!#3"(
3UQ
(-#
"$#
'823
3UQ
.-"$+
3UQ
-.-$
$ !#3
3UQ
'.+"
#+.2
./$-
-.-$
2$3/
%4-#
3UQ
2$3/
6(-"
$
/.6
.%%
.%%"$+
3UQ
.(6
#.-3
3UQ
.(6
#(6
2$3/+.
3UQ
2$3/'(
3UQ
'823
3UQ
.-"$+
3UQ
-.-$
$ !#3
3UQ
'.+"
#+.2
./$-
-.-$
6(-"
%4-#
3UQ
.%%"$+
3UQ
./$-
$ !#3
3UQ
#+.2
./$-
$
%4-#
3UQ
/.6
%4-#
3UQ
.%%
%4-#
3UQ
Til normaltilstand 1.0
1.3
1.3
1.3
1.3
1.3

22 23
2!5$
,$,. 8
3UQ
2!5$
+.!"
,$,
2$34/
3UQ
,$,
"(2/
#!+
2(,
/!22
+!-&
Rutediagram
avancerede indstillinger (ADV.SET)
"(2/
2$34/
3UQ
#.-3 !
3UQ
+(&'3
3UQ
5!+5$
3UQ
!
#!+
2$34/
3UQ
8$2
#!++.
3UQ
8$2
-.
3UQ
-.
8$2
#!+'(
3UQ
8$2
-.
3UQ
-.
8$2
42$#!+
3UQ
8$2
-.
2(,
2$34/
3UQ
8$2
$-2(,
3UQ
8$2
-.
3UQ
-.
$+2(,
3UQ
+!-&
2$34/
3UQ
4*
+!-&4!
3UQ
"$"*
$2%
(32$
4*
Til normaltilstand 1.0
[01]
[02]
[03]
[04]
[05]
[06]
[07]
[08]
[09]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
[43]
[44]
[45]
[46]
[47]
[49]
[50]
[51]
[52]
[53]
[54]
[55]
[56]
[57]
[58]
[59]
[60]
[61]
[62]
Angiv korrekt password
Gå til avanceret opsætningsmenu?
Vælg temperaturindgang
Vælg potentiometerindgang
Vælg lineær modstandsindgang
Vælg strømindgang
Vælg spændingsindgang
Vælg 0.0-1 V indgangsområde
Vælg 0.2-1 V indgangsområde
Vælg 0-5 V indgangsområde
Vælg 1-5 V indgangsområde
Vælg 0-10 V indgangsområde
Vælg 2-10 V indgangsområde
Vælg 0-20 mA indgangsområde
Vælg 4-20 mA indgangsområde
Vælg 2-leder følertilslutning
Vælg 3-leder følertilslutning
Vælg 4-leder følertilslutning
Indstil modstandsværdi lav
Indstil modstandsværdi høj
Vælg Celsius som temperaturenhed
Vælg Fahrenheit som temperaturenhed
Vælg TC-følertype
Vælg Ni-følertype
Vælg Pt-følertype
Vælg displayenheder
Vælg kommaplacering
Indstil displayområde lav
Indstil displayområde høj
Indstil relæer i % af indgangsområde
Indstil relæer i displayenheder
Vælg Pt10 som følertype
Vælg Pt20 som følertype
Vælg Pt50 som følertype
Vælg Pt100 som følertype
Vælg Pt200 som følertype
Vælg Pt400 som følertype
Vælg Pt500 som følertype
Vælg Pt1000 som følertype
Vælg Ni50 som følertype
Vælg Ni100 som følertype
Vælg Ni120 som følertype
Vælg Ni1000 som følertype
Vælg TC-B som følertype
Vælg TC-E som følertype
Vælg TC-J som følertype
Vælg TC-K som følertype
Vælg TC-L som følertype
Vælg TC-N som følertype
Vælg TC-R som følertype
Vælg TC-S som følertype
Vælg TC-T som følertype
Vælg TC-U som følertype
Vælg TC-W3 som følertype
Vælg TC-W5 som følertype
Vælg TC-LR som følertype
Vælg OFF-funktion - relæ er permanent OFF
Vælg POWER-funktion - relæ viser power-status OK
Vælg FEJL-funktion - relæ viser kun følerfejl
Vælg VINDUE-funktion - relæet styres af 2 setpunkter
Vælg SETPUNKT-funktion - relæet styres af 1 setpunkt
Vælg kontakt normalt åben
Vælg kontakt normalt lukket
Indstil relæ-setpunkt
Aktiver relæ ved faldende signal
Aktiver relæ ved stigende signal
Rullende hjælpetekster i displaylinie 3
Indstil relæ-hysterese
Ingen følerfejlsaktion - udefineret status ved fejl
Relækontakt bryder ved fejl
Relækontakt slutter ved fejl
Hold relæstatus ved fejl
Sæt relæ ON-forsinkelse i sekunder
Sæt relæ OFF-forsinkelse i sekunder
Relækontakt er lukket inden for vinduet
Relækontakt is åben inden for vinduet
Indstil setpunkt høj for relævindue
Indstil setpunkt lav for relævindue
Indstil hysterese for relævindue
Ingen følerfejlsaktion - udefineret status ved fejl
Relækontakt bryder ved fejl
Relækontakt slutter ved fejl
Hold relæstatus ved fejl
Sæt relæ ON-forsinkelse i sekunder
Sæt relæ OFF-forsinkelse i sekunder
Relækontakt bryder ved fejl
Relækontakt slutter ved fejl
Gå til password-indstilling
Gå til simuleringstilstand
Udfør proceskalibrering
Gå til displayopsætning
Udfør memory-operationer
Overfør gemt opsætning til 4131
Gem 4131-opsætning i 4501
Juster LCD-kontrast
Juster LCD-baggrundsbelysning
Angiv TAG-nr. - udfyld alle pladser
Kalibrer indgang lav til procesværdi?
Kalibrer indgang høj til procesværdi?
Tillad simuleringstilstand?
Indstil simuleringsværdi for indgang
Relæsimulering - brug og til at skifte mellem
relæ 1 og 2
Tillad passwordbeskyttelse?
Angiv nyt password
Tillad Fastset funktionalitet?
Relæ setpunkt - tryk OK for at gemme
Relæ setpunkt - Read only
Vælg sprog
Brug proceskalibreringsværdier?
Indstil værdi for lavt kalibreringspunkt
Indstil værdi for højt kalibreringspunkt
/!22
2$34/
3UQ
8$2
$-/!22
3UQ
8$2
-.
-$6/!2
3UQ
8$2
$-%!23
3UQ
8$2
-.
2.0
2.0 I undermenuen simulering (SIM) skal tryk-
kes for at returnere til normaltilstand 1.0
-.

24 25
Grafisk afbildning af relæfunktionen setpunkt:
Grafisk afbildning af relæfunktionen vindue:
t
Off N.C.
On N.C. On N.C.
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
0
Off N.O. Off N.O.
On N.O.
t
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
0
Off N.O. Off N.O.On N.O.
Off N.C.On N.C. On N.C.
RelæenhederRelæenheder
Setpunkt = 50
Hysterese = 10
Hysterese = 10
Setpunkt = 50
Relæaktion: Stigende Relæaktion: Faldende
1
2
On On On
Off OffOff Off Off Off
On On On
1
2
t
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
0
t
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
0
222
2
1 1 11
Relæenheder
Øvre setpunkt = 60
Hysterese = 5
Hysterese = 5
Nedre setpunkt = 40
Relæfunktion: Vindue (vist for stigende signal)
Kontakt: Lukket inden for vindue =
Kontakt: Åben inden for vindue =
Relæenheder
Øvre setpunkt = 60
Hysterese = 5
Hysterese = 5
Nedre setpunkt = 40
Relæfunktion: Vindue (vist for faldende signal)
Kontakt: Lukket inden for vindue =
Kontakt: Åben inden for vindue =
UNIVERSAL TRIP AMPLIFIER
PReasy 4131
CONTENTS
Warnings ............................................................................ 26
Safety instructions.............................................................. 27
Declaration of Conformity .................................................. 29
How to dismantle SYSTEM 4000....................................... 30
Application ......................................................................... 31
Technical characteristics.................................................... 31
Mounting / installation........................................................ 31
PR 4501 Display / programming front ............................... 32
Applications........................................................................ 33
Order codes ....................................................................... 34
Electrical specifications...................................................... 34
Visualisation in the 4501 of sensor error detection
and input signal outside range ...................................... 37
Connections ....................................................................... 39
Block diagram .................................................................... 40
Configuration / operating the function keys ...................... 41
Routing diagram................................................................. 42
Routing diagram, advanced settings (ADV.SET)................ 46
Scrolling help text in display line 3 .................................... 47
Graphic depiction of relay action Setpoint ........................... 48
Graphic depiction of relay action Window .......................... 48
25

26 27
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand.
Potentially lethal situations.
The CE mark proves the compliance of the module with
the essential requirements of the directives.
The double insulation symbol shows that the module
is protected by double or reinforced insulation.
SAFETY INSTRUCTIONS
DEFINITIONS:
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and
50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and
also troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate
the knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING:
Unpack the module without damaging it and make sure that the manual always
follows the module and is always available. The packing should always follow
the module until this has been permanently mounted.
Check at the receipt of the module whether the type corresponds to the one
ordered.
ENVIRONMENT:
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All modules fall under Installation Category II, Pollution Degree 1, and Insulation
Class II.
MOUNTING:
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
module.
2726
WARNING!
This module is designed for connection to hazardous electric
voltages.
Ignoring this warning can result in severe personal injury or
mechanical damage.
To avoid the risk of electric shock and fire, the safety instruc-
tions of this manual must be observed and the guidelines
followed. The specifications must not be exceeded, and the
module must only be applied as described in the following.
Prior to the commissioning of the module, this manual must be
examined carefully.
Only qualified personnel (technicians) should install this module.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
WARNING
To keep the safety distances, the relay contacts on the module
must not be connected to both hazardous and non-hazardous
voltages at the same time.
SYSTEM 4000 must be mounted on a DIN rail according to DIN
46277.
WARNING!
Until the module is fixed, do not connect hazardous voltages to
the module.
The following operations should only be carried out on a
disconnected module and under ESD safe conditions:
General mounting, connection and disconnection of wires.
Troubleshooting the module.
Repair of the module and replacement of circuit breakers
must be done by PR electronics A/S only.
HAZARD-
OUS
VOLTAGE
INSTAL-
LATION
GENERAL

28 29
DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 4131
Name: Universal trip amplifier
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326
This declaration is issued in compliance with article 10, subclause 1 of the EMC
directive. For specification of the acceptable EMC performance level, refer to
the electrical specifications for the module.
The Low Voltage Directive 73/23/EEC and later amendments
EN 61010-1
Rønde, 29 June 2005 Peter Rasmussen
Manufacturer’s signature
29
Should there be any doubt as to the correct handling of the module, please
contact your local distributor or, alternatively,
PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Denmark,
tel: +45 86 37 26 77.
Mounting and connection of the module should comply with national legislation
for mounting of electric materials, i.a. wire cross section, protective fuse, and
location. Descriptions of input / output and supply connections are shown in the
block diagram and side label.
The following apply to fixed hazardous voltages-connected modules:
The max. size of the protective fuse is 10 A and, together with a power
switch, it should be easily accessible and close to the module. The
power switch should be marked with a label indicating that it will switch
off the voltage to the module.
CALIBRATION AND ADJUSTMENT:
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.
NORMAL OPERATION:
Operators are only allowed to adjust and operate modules that are safely fixed
in panels, etc., thus avoiding the danger of personal injury and damage. This
means there is no electrical shock hazard, and the module is easily accessible.
CLEANING:
When disconnected, the module may be cleaned with a cloth moistened with
distilled water or ethyl alcohol.
LIABILITY:
To the extent that the instructions in this manual are not strictly observed, the
customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.
28

30 31
UNIVERSAL TRIP AMPLIFIER
PReasy 4131
• Trip amplifier with input for RTD, TC, Ohm,
potentiometer, mA and V
• 2 adjustable alarm limits
• Programmable via display front
• 2 relay outputs
• Universal AC or DC supply
Application:
• Process control with 2 pairs of potential-free relay contacts which can be con-
figured to suit any application.
• Trip amplifier with window fonction allowing the relay to change state within a
high and a low setpoint on the input span.
• Sophisticated sensor error surveillance, where one relay holds the state imme-
diately prior to the sensor error, thus allowing the process to continue. The
other relay can be set for sensor error alarm so that the defect sensor can be
replaced immediately.
• The 4131 is designed according to strict safety requirements and is thus suit-
able for application in SIL 2 installations.
Technical characteristics:
• When 4131 is used in combination with the 4501 display / programming front,
all operational parameters can be modified to suit any application. As the
4131 is designed with electronic hardware switches, it is not necessary to
open the module for setting of DIP switches.
• A green / red front LED indicates normal operation and malfunction. A yellow
LED is ON for each active output relay.
• Continuous check of vital stored data for safety reasons.
• 3-port 2.3 kVAC galvanic isolation.
Mounting / installation:
• Mounted vertically or horizontally on a DIN rail. As the modules can be
mounted without any distance between neighbouring units, up to 42 modules
can be mounted per metre.pr. meter..
31
HOW TO DISMANTLE SYSTEM 4000
First, remember to demount the connectors with hazardous voltages.
Picture 1:
Detach the module from the DIN rail
by lifting the bottom lock.
30

32 33
PR 4501 DISPLAY / PROGRAMMING FRONT
Application:
• Communications interface for modification of operational parameters in 4131.
• Can be moved from one 4131 module to another and download the configu-
ration of the first transmitter to subsequent transmitters.
• Fixed display for visualisation of process data and status.
Technical characteristics:
• LCD display with 4 lines; 1 line with the height 5.57 mm, 2 lines with the
height 3.33 mm, and 1 line with fixed icons.
• Programming access can be blocked by assigning a password. The password
is saved in the transmitter in order to ensure a high degree of protection
against unauthorised modifications to the configuration.
Mounting / installation:
• Click 4501 onto the front of 4131.
3332
Applications
Input signals:
Current
Volt-
age
Potenti-
ometer RTD and lin. R TC
Connect., wires
Output signals:
Supply:
21.6...253 VAC
or
19.2...300 VDC
33
32
31
+
-
+
-
44
43
42
41
Relays
24
23
22
21

34 35
Auxiliary supplies:
2-wire supply (terminal 44...43)................... 25...16 VDC / 0...20 mA
Max. wire size.............................................. 1 x 2.5 mm2stranded wire
Screw terminal torque................................. 0.5 Nm
Relative humidity......................................... < 95% RH (non-cond.)
Dimensions, without display front (HxBxD).. 109 x 23.5 x 104 mm
Dimensions, with display front (HxBxD)...... 109 x 23.5 x 116 mm
Tightness (enclosure / terminals) ................ IP50 / IP20
Weight ......................................................... 170 g
RTD, linear resistance and potentiometer input:
Cable resistance per wire (max.)................. 50 Ω
Sensor current, RTD.................................... Nom. 0.2 mA
35
ORDER CODES:
4131 = Universal trip amplifier
4501 = Display / programming front
Electrical specifications:
Specifications range:
-20°C to +60°C
Common specifications:
Supply voltage, universal ............................ 24...230 VAC ±10%
50...60 Hz
24...250 VDC ±20%
Max. consumption ...................................... ≤2.5 W
Fuse............................................................. 400 mA SB / 250 VAC
Isolation voltage, test / operation ............... 2.3 kVAC / 250 VAC
Communications interface .......................... Programming front 4501
Signal / noise ratio ...................................... Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%):
Temperature input...................................
≤ 1 s
mA / V input............................................ ≤ 400 ms
Calibration temperature .............................. 20...28°C
Accuracy, the greater of the general and basic values:
34
EMC immunity influence ..................................... < ±0.5% of span
Extended EMC immunity:
NAMUR NE 21, A criterion, burst ....................... < ±1% of span
Basic values
Input
type Basic
accuracy Temperature
coefficient
mA ≤±4 µA ≤±0.4 µA / °C
Volt ≤±20 µV ≤±2 µV / °C
Pt100 ≤±0.2°C ≤±0.01°C / °C
Lin. R ≤±0.1 Ω≤±10 mΩ/ °C
Potentiometer ≤±0.1 Ω≤±0.01 Ω/ °C
TC type:
E, J, K, L, N, T, U ≤±1°C ≤±0.05°C / °C
TC type: B, R, S,
W3, W5, LR ≤±2°C ≤±0.2°C / °C
General values
Input
type Absolute
accuracy Temperature
coefficient
All ≤±0.1% of span ≤±0.01% of span / °C Input
type Min.
value Max.
value Norm
Pt100
Ni100
Lin. R
Potentiometer
-200°C
-60°C
0 Ω
10 Ω
+850°C
+250°C
10000 Ω
100 kΩ
IEC60751
DIN 43760
-
-

36 37
Relay outputs:
Max. voltage................................................ 250 VRMS
Max. current ................................................ 2 A / AC or 1 A / DC
Max. AC power ........................................... 500 VA
Sensor error detection ................................ Break / Make / Hold
Observed authority requirements: Standard:
EMC 2004/108/EC:
Emission and immunity .......... EN 61326
LVD 73/23/EEC............................................ EN 61010-1
* UL, Standard for Safety............................ UL 508
* approval pending, expected autumn 2005
of span = of the currently selected measurement range
Visualisation in the 4501 of sensor error detection and
input signal outside range
37
Effect of sensor cable resistance
(3- / 4-wire), RTD......................................... < 0.002 Ω/ Ω
Sensor error detection, RTD ....................... Yes
Short circuit detection, RTD........................ < 15 Ω
TC input:
Cold junction compensation (CJC) ............. < ±1.0 °C
Sensor error detection ................................ Yes
Sensor error current:
when detecting ....................................... Nom. 2 µA
else.......................................................... 0 µA
Current input:
Measurement range .................................... -1...25 mA
Programmable measurement ranges.......... 0...20 and 4...20 mA
Input resistance........................................... Nom. 20 Ω+ PTC 50 Ω
Voltage input:
Measurement rages .................................... -20 mV...12 VDC
Programmable measurement ranges.......... 0...1 / 0.2...1 / 0...5 / 1...5 /
0...10 and 2...10 VDC
Input resistance........................................... Nom. 10 MΩ
36
Type Min.
value Max.
value Norm
B
E
J
K
L
N
R
S
T
U
W3
W5
LR
+400°C
-100°C
-100°C
-180°C
-200°C
-180°C
-50°C
-50°C
-200°C
-200°C
0°C
0°C
-200°C
+1820°C
+1000°C
+1200°C
+1372°C
+900°C
+1300°C
+1760°C
+1760°C
+400°C
+600°C
+2300°C
+2300°C
+800°C
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
IEC 60584-1
IEC 60584-1
IEC 60584-1
IEC 60584-1
DIN 43710
ASTM E988-90
ASTM E988-90
GOST 3044-84
Sensor error check:
Module: Configuration Sensor error detection:
4131
R1, ERR.ACT=NONE - R2, ERR.ACT=NONE,
OUT.ERR=NONE. OFF
Else: ON
Other manuals for PReasy 4131
2
Table of contents
Languages:
Other PR electronics Amplifier manuals