PR 3186 User manual

3186
SIGNALS THE BEST
2-wire transmitter isolator
Model no. 3186
No. 3186V100-UK

PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere m. Vi har modulerne, du kan stole på i selv
barske miljøer med elektrisk støj, vibrationer og temperaturud-
sving, og alle produkter opfylder de strengeste internationale stan-
darder. Vores motto »Signals the Best« er indbegrebet af denne
loso – og din garanti for kvalitet.
PR electronics A/S offers a wide range of analogue and digital
signal conditioning modules for industrial automation. The product
range includes Isolators, Displays, Ex Interfaces, Temperature
Transmitters, and Universal Modules. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature uctuations, and all products comply with the
most exacting international standards. »Signals the Best« is the
epitome of our philosophy – and your guarantee for quality.
PR electronics A/S offre une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux afcheurs, des isolateurs aux
interfaces SI, jusqu’aux modules universels. Vous pouvez compter
sur nos produits même dans les conditions d’utilisation sévères,
p.ex. bruit électrique, vibrations et uctuations de température.
Tous nos produits sont conformes aux normes internationales les
plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne
de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsmodule für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner, und
Universalgeräte. Sie können unsere Geräte auch unter extremen
Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen
und Temperaturschwingungen vertrauen, und alle Produkte von
PR electronics werden in Übereinstimmung mit den strengsten
internationalen Normen produziert. »Signals the Best« ist Ihre
Garantie für Qualität!
DK
UK
FR
DE
1148

3186V100-IN 1
6 MM SERIES
2-WIRE TRANSMITTER ISOLATOR
3186
CONTENTS
Warning .......................................................................................... 2
Safety instructions.......................................................................... 3
Mounting and demounting of system 3100................................... 5
Installation on DIN rail .................................................................... 6
Marking........................................................................................... 6
Side label........................................................................................ 7
EC declaration of conformity ......................................................... 8
Applications.................................................................................... 9
Technical characteristics................................................................ 9
Mounting / installation.................................................................... 9
Order codes for 3186..................................................................... 10
Specifications................................................................................. 10
Connections ................................................................................... 13
NB.: Click on the entries in the table of contents to go to the desired section.

2 3186V100-IN
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Read the manual
before installation and commissioning of the device in
order to avoid incidents that could lead to personal injury
or mechanical damage.
The CE mark proves the compliance of the device with
the essential requirements of the directives.
Ex devices have been approved according to the ATEX
directive for use in connection with installations in
explosive areas.
WARNING
To avoid the risk of electric shock and fire, the safety instructions
of this guide must be observed and the guidelines followed. The
specifications must not be exceeded, and the device must only be
applied as described in the following. Prior to the commissioning of
the device, this installation guide must be examined carefully. Only
qualified personnel (technicians) should install this device. If the
equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired. Until the
device is fixed, do not connect hazardous voltages to the device.
Repair of the device must be done by PR electronics A/S only.
In applications where hazardous voltage is connected to in-/
outputs of the device, sufcient spacing or isolation from wires,
terminals and enclosure - to surroundings (incl. neighbouring
devices), must be ensured to maintain protection against electric
shock.
Potential electrostatic charging hazard. To avoid the risk of
explosion due to electrostatic charging of the enclosure, do
not handle the units unless the area is known to be safe, or
appropriate safety measures are taken to avoid electrostatic
discharge.
GENERAL
HAZARD-
OUS
VOLTAGE
CAUTION

3186V100-IN 3
SAFETY INSTRUCTIONS
RECEIPT AND UNPACKING
Unpack the device without damaging it. The packing should always follow the
device until this has been permanently mounted. Check at the receipt of the
device whether the type corresponds to the one ordered.
ENVIRONMENT
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All devices can be used for Measurement Category II and Pollution Degree 2.
The module is designed to be safe at least under an altitude up to 2 000 m.
MOUNTING
Mounting and connection of the device should comply with national legislation
for mounting of electric materials, i.e. wire cross section, protective fuse, and
location. Descriptions of input / output and supply connections are shown in this
installation guide and on the side label.
The device is provided with eld wiring terminals and shall be supplied from a
Power Supply having double / reinforced insulation. A power switch should be
easily accessible and close to the device. The power switch shall be marked as the
disconnecting unit for the device.
SYSTEM 3000 must be mounted on a DIN rail according to EN 60715.
UL installation
Use 60/75°C copper conducters only.
Wire size ........................... AWG 26-12
UL le number.................. E314307
The device is an Open Type Listed Process Control Equipment. To prevent injury
resulting from accessability to live parts the equipment must be installed in an
enclosure.
The power Supply unit must comply with NEC Class 2, as described by the National
Electrical Code®(ANSI / NFPA 70).
cFMus installation in Division 2 or Zone 2
Class I, Div. 2, Group A, B, C, D T4 or I, Zone 2, AEx nA IIC T4 or Ex nA IIC T4.
In class I, Division 2 or Zone 2 installations, the subject equipment shall be
mounted within a tool-secured enclosure which is capable of accepting one or
more of Class I, Division 2 wiring methods specied in the National Electrical
Code (ANSI/NFPA 70) or in Canada in the Canadian Electrical Code (C22.1).
The 3000 System Isolators and Converters must be connected to limited output
NEC Class 2 circuits, as outlined in the National Electrical Code® (ANSI / NFPA
70), only. If the devices are connected to a redundant power supply (two separate
power supplies), both must meet this requirement.
Where installed in outdoor or potentially wet locations the enclosure shall at a
minimum meet the requirements of IP54.

4 3186V100-IN
Warning: Substitution of components may impair suitability for zone 2 / division 2.
Warning: To prevent ignition of the explosive atmospheres, disconnect power
before servicing and do not separate connectors when energised and an
explosive gas mixture is present.
Warning: Do not mount or remove devices from the power rail when an explosive
gas mixture is present.
IECEx, ATEX installation in Zone 2
IECEx KEM 10.0068 X...... Ex nA IIC T4 Gc
KEMA 10ATEX0147 X....... II 3G Ex nA IIC T4
For safe installation the following must be observed. The device shall only be
installed by qualied personnel who are familiar with the national and international
laws, directives and standards that apply to this area.
Year of manufacture can be taken from the rst two digits in the serial number.
The devices shall be installed in a suitable enclosure providing a degree of
protection of at least IP54 according to EN60529, taking into account the
environmental conditions under which the equipment will be used.
When the temperature under rated conditions exceeds 70°C at the cable or
conduit entry point, or 80°C at the branching point of the conductors, the
temperature specication of the selected cable shall be in compliance with the
actual measured temperature.
Provisions shall be made to prevent the rated voltage from being exceeded by
transient disturbances of more than 40%.
For installation on power rail in Zone 2, only Power Rail type 9400 supplied by
Power Control Unit type 9410 is allowed.
To prevent ignition of the explosive atmospheres, disconnect power before
servicing and do not separate connectors when energised and an explosive gas
mixture is present.
Do not mount or remove devices from the power rail when an explosive gas
mixture is present.
Cleaning
When disconnected, the device may be cleaned with a cloth moistened with
distilled water.

3186V100-IN 5
MOUNTING AND DEMOUNTING OF SYSTEM 3100
Picture 1:
Mounting on DIN rail.
Click the device onto the rail
Picture 2:
Demounting from DIN rail
First, remember to demount the connectors with
hazardous voltages.
Detach the device from the DIN rail by lifting the
bottom lock.
Picture 3:
Wire size AWG 26-12 / 0.13 x 2.5 mm2stranded wire.
Screw terminal torque 0.5 Nm.

6 3186V100-IN
INSTALLATION ON DIN RAIL
3186 must be supported by a module stop for marine applications.
(PR part number 9404).
MARKING
The front cover of the 3100 series
has been designed with an
area for affixation of a click-on
marker. The area assigned to
the marker measures 5 x 7.5
mm. Markers from Weidmüller’s
MultiCard System, type MF
5/7.5, are suitable.
Module stop

3186V100-IN 7
}
}
}
}
SIDE LABEL
Approvals
Pin
connections
Type no.
Terminal numbers

8 3186V100-IN
EC DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 3186
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326-1 : 2006
For specification of the acceptable EMC performance level, refer to the
electrical specifications for the devices.
The Low Voltage Directive 2006/95/EC and later amendments
EN 61010-1 : 2001
The ATEX Directive 94/9/EC and later amendments
EN 60079-0 : 2009 and EN 60079-15 : 2005
ATEX certificate: KEMA 10ATEX0147 X
Notified body
DEKRA Certification B.V. (0344)
Utrechtseweg 310, 6812 AR Arnhem
P.O. Box 5185, 6802 ED Arnhem
The Netherlands
Rønde, 30 March 2012 Kim Rasmussen
Manufacturer’s signature

3186V100-IN 9
3186: 2-WIRE TRANSMITTER ISOLATOR
• 1 or 2 channel 2-wire transmitter isolator
• Signal 1:1 functional range 3.5...23 mA
• Low channel voltage drop and fast response time
• Excellent accuracy
• Slimline 6mm housing
Applications
• 1:1 output loop powered isolator of 2-wire transmitter current signals.
• AneasymountingDINrailunit.
• Averycompetitivechoiceintermsofbothpriceand technologyforgalvanic
isolation of 2-wire transmitter signals.
• Providessurgesuppressionandprotectscontrolsystemsfromtransientsand
noise.
• Eliminationofgroundloopsandmeasurementoffloatingsignals.
• ThedevicecanbemountedinSafeareaorinZone2andCl.1Div2.area.
Technical characteristics
• 3186ispoweredbythehostloopvoltage.
• Widesupplyrangefrom6...35V.
• Lowinputtooutputvoltagedroptyp2.5V.
•Excellent conversion accuracy, better than 0.05% in the range 3.8…20.5 mA.
• Functional range is 3.5...23mA which means that 3186 is NAMUR NE43
compliant.
• Inputsandoutputsarefloatingandgalvanicallyseparated.
• Highgalvanicisolationof2.5kVAC.
• Fastresponsetime<5msec.
• Excellentsignal/noiseratio>60dB.
Mounting / installation
•DINrailmountingwithupto330channelspermetre.
•Temperatureoperationrangeisfrom-25...+70°C.

10 3186V100-IN
Specifications
Environmental conditions:
Specifications range.................................... -25°Cto+70°C
Storage temperature ................................... -40°Cto+85°C
Calibration temperature............................... 20...28°C
Relative humidity......................................... <95%RH(non-cond.)
Protection degree........................................ IP20
Installation in pollution degree 2 & overvoltage category II.
Mechanical specifications:
Dimensions(HxWxD)................................... 113 x 6.1 x 115 mm
Weight approx. ............................................ 70 g
DIN rail type................................................. DIN EN 60715 - 35mm
Wire size...................................................... 0.13...2.5 mm2/ AWG
26...12 stranded wire
Screw terminal torque ................................. 0.5 Nm
Common electrical specifications:
Supply voltage............................................. 6...35 VDC
Voltage drop, input to output typ................ 2.5 V
Internal consumption .................................. 50 mW per channel
Isolation voltage, test .................................. 2.5 kVAC
Working isolation voltage ............................ 300 VAC / 250 VAC (Ex)
Signal / noise ratio ...................................... >60dB
Response time (0...90%, 100...10%) ........... <5ms
Cut- off frequency (3 dB)............................. 100Hz
Order codes for 3186:
Type Unit channels
3186A1
3186A2
1
2
Accessories for 3186:
Type Function
9404 Module stop

3186V100-IN 11
Input and Output specifications:
Available input transmitter (Tx) supply........ 3.5...32.5 V
Signal range, input to output ...................... 3.8...20.5 mA
Signal conversion........................................ 1:1
Functional range.......................................... 3.5...23 mA
Output loop current limitation, typ.............. 24 mA
Current output overload, max..................... 50 mA
Accuracycalculationexample->Tamb = 50°C and Vsupply = 24 VDC:
Totalaccuracy=Absoluteaccuracy+Temperaturecoefficient
= ± (8 µA+(0.02µA x (25°C x 24V))) = ≤ ± 20 µA
* of span = 4...20 mA
EMC immunity influence ........................... <±0.5%ofspan
Extended EMC immunity:
NAMUR NE 21, A criterion, burst ............. <±1%ofspan
Accuracy values
Input
type Absolute
accuracy Temperature coefficient
D°C = [Tamb - 25°C]
mA ≤± 8 µA ≤± 0.02 µA x (D°CxVsupply)@Tamb>25°C
≤± 0.07 µA x (D°CxVsupply)@Tamb<25°C

12 3186V100-IN
Approvals:
EMC 2004/108/EC ...................................... EN 61326-1
LVD 2006/95/EC.......................................... EN 61010-1
UL, Standard for Safety .............................. UL 61010-1
Safe Isolation............................................... EN 61140
GOST R
Marine:
Det Norske Veritas, Ships & Offshore ......... Stand. f. Certific. No. 2.4
Germanischer Lloyd .................................... VI-7-2
Ex:
ATEX 94/9/EC.............................................. KEMA 10ATEX0147 X
IECEx........................................................... KEM 10.0068 X
c FM us ....................................................... 3041043 -C

3186V100-IN 13
Tx
5
6
7
8
1
2
3
4
Tx
+
-
+
-
+
+
CONNECTIONS
3186
Input
ch. 1
Output
ch. 1
Input
ch. 2
Output
ch. 2
+Vsupply
+Vsupply
4...20 mA
4...20 mA

Programmable displays with a wide
selection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Displays
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specic to universal transmitters.
Temperature
Galvanic isolators for analogue and digital
signalsaswellasHART®signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Isolation
Interfaces for analogue and digital signals
aswellasHART®signals between sensors / I/P converters /
frequency signals and control systems in Ex zone 0, 1 & 2
and for some modules in zone 20, 21 & 22.
Ex interfaces
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
Universal

Head ofce
Denmark www.prelectronics.com
Lerbakken10 tel.+4586372677
DK-8410Rønde fax+4586373085
www.prelectronics.fr
sales@prelectronics.fr
www.prelectronics.de
sales@prelectronics.de
www.prelectronics.es
sales@prelectronics.es
www.prelectronics.it
sales@prelectronics.it
www.prelectronics.se
sales@prelectronics.se
www.prelectronics.co.uk
sales@prelectronics.co.uk
www.prelectronics.com
sales@prelectronics.com
This manual suits for next models
1
Table of contents
Other PR Industrial Electrical manuals
Popular Industrial Electrical manuals by other brands

Nova Technology International, LLC
Nova Technology International, LLC Lock-Up installation manual

Anybus
Anybus Wireless Bolt user manual

Murata
Murata GRM0225C1E9R4DA03 Series Reference sheet

fadini
fadini BAYT 980 Instruction booklet

SEW-Eurodrive
SEW-Eurodrive MOVIGEAR classic MGF**1-DSM-C Series operating instructions

Murata
Murata GRM32DR60J226KA01 Series Reference sheet