Premier Clean Ducted Vacuum User manual

Ducted Vacuum
Owner’s Manual
User instruction manual and warranty information.
Please read this before installing or using your
Premier Clean Ducted Vacuum Unit.
For replacement bags
buy online at www.premierclean.com.au
or to find your local dealer
For Warranty registration go to www.premierclean.com.au 1
www.premierclean.com.au

2
Information
For Replacement Bags Buy Online at
www.premierclean.com.au
For Accessories Buy Online at
www.premierclean.com.au
WARNING
USE ONLY GENUINE PREMIER CLEAN SYNTHETIC FILTER BAGS.
FAILURE TO DO SO WILL VOID YOUR WARRANTY.
DO NOT VACUUM UP WATER, PLASTER DUST,
BRICK OR CONCRETE DUST.

3
Table of Contents
Installation 4-5
Changing Bag/Filter 6
Operating Instructions
Operation & Care 7
Accessories 8
Hose Sets 9
Trouble Shooting 10-11
Warranty Information 12-13

4
Unit Installation
Using the mounting plate provided with
your vacuum cleaner, secure the unit to the
wall (figure 1), at the height allowing
easy access to change the bag.
Please note Monarch/Compact units
must be a minimum 300mm off the ground.
(Do not store any particles underneath the
vacuum)
The connections to the piping system will
require some basic tools: a mitre box and
small saw or a pipe cutter (figure 2)
Contrary to all other connections in the
piping system, do not glue the last
fitting to your unit.

5
Low Voltage Connections
Connect the low voltage wires to the
low voltage inlet on your unit. To do
so, simply strip wire overs 1/2 cm,
remove the terminals from the low
voltage inlet on the unit, and proceed
according to the types of inlet and
wire used.
All types of wire:
Twist the stranded wire to tighten
the loose strands together before
proceeding. Insert the wire into the
terminal (blue connector).
Using your wire strippers, tighten
the terminal at two places: at the
front, to hold the wire in place, and
at the back to tighten the insulator
around the wire. If the insulator does
not completely cover the stripped
wire, use electrical tape to insulate
the wire adequately, and prevent all
contact between the 2 wires. Insert the
terminal into the low voltage inlet.
To disconnect:
Do not pull on wire. Simply remove
the terminal from the low voltage inlet.

6
Motor
There is no maintenance to be performed on the actual motor of your ducted vacuum. The
most important tips for a longer vacuum life are - to keep the inside of the unit (canister)
itself clean - make sure you do not vacuum up any harmful dusts or ANY liquids. Should you
require a service to your unit please contact the dealer who you purchased the unit from or
call us on 1300 881 608 to find a dealer near you.
PREMIER
UNIT
MONARCH
UNIT
PREMIER
UNIT
OVERLOAD
SWITCH
OVERLOAD
SWITCH
OVERLOAD
SWITCH
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
WEIGHTED
FILTER
WEIGHTED
FILTER
BAG ADAPTER
BAG ADAPTER
PLATE
BIN
BIN
PREMIER
UNIT
MONARCH
UNIT PREMIER
UNIT
OVERLOAD
SWITCH
OVERLOAD
SWITCH
OVERLOAD
SWITCH
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
WEIGHTED
FILTER
WEIGHTED
FILTER
BAG ADAPTER
BAG ADAPTER
PLATE
BIN
BIN
PREMIER
UNIT
MONARCH
UNIT
PREMIER
UNIT
OVERLOAD
SWITCH
OVERLOAD
SWITCH
OVERLOAD
SWITCH
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
LOW VOLTAGE
CONNECTION
WEIGHTED
FILTER
WEIGHTED
FILTER
BAG ADAPTER
BAG ADAPTER
PLATE
BIN
BIN
Monarch 250, 490, 550,
650, 850, 950, Compact
2, Typhoon, Premier 200
•Liftlidandremovebag
from bag adaptor
•Donotthrowawaybag
adaptor
•Liftbottomplateandclean
around airway
•Replacebottomplate
•Installnewbagtobag
adaptor
•Fitlidbackontotheunit
Premier 250, 520, 550,
850, 1700 Typhoon
Series
•Unclipbottombin,empty
contents
•Removeweightedlterand
replace/ or clean
•Ensurelterisinstalledinto
groove
•Replacebin
Premier 3000, 4000, 5000,
6000, 9000 Bagless model
•Unclipbottombin,empty
contents
•Removeweightedlterand
remove/or clean
•Ensurelterisinstalledinto
groove
•Replacebin
Premier 3000, 4000, 5000,
6000 Bag model
•Unclipbottombin,andremove
bag from bag adaptor
•Donotthrowawaybag
adaptor
•Cleansecondarylterlocated
underneath motor compartment
•Installnewbagtobagadaptor
•Replacebin
Compact/Premier Monarch
Changing Bags and Filters
WARNING
“FAILURE TO USE PREMIER CLEAN SYNTHETIC FILTER
BAGS WILL CAUSE MOTOR FAILURE AND VOID WARRANTY”
For all bagless systems weighted filter to be replaced once a year
USE ONLY GENUINE PREMIER CLEAN SYNTHETIC FILTER BAGS.
FAILURE TO DO SO WILL VOID YOUR WARRANTY.

7
Operation & Care
STARTING VACUUM – Simply open outlet cover, insert hose and system will
automatically start. To stop, remove hose and allow suction to reduce before
closing the inlet.
If you have chosen a switch on/off handle hose plug the hose into the inlet with
arrow facing up, use handle on/off switch to operate.
Operating Garage Point. Open inlet cover and insert hose. Turn the switch on
the side of the system to the ON position. When finished turn switch off and
remove hose.
TIPS TO CARE FOR YOUR DUCTED VACUUM SYSTEM – Your system’s
unit is warranted against defective materials and workmanship but not against
misuse. There is a service charge for repairing or replacing damaged or
misused components of the system and for service calls. To ensure your ducted
system is a life-time improvement for you and your family, follow these simple
tips and you will enjoy it for many years.
1. Do not place any articles around the motor of the power unit.
To do so could cause the motor to overheat as it will impair the cooling of the motor.
2. Use one inlet at a time to maintain proper air flow.
To use more than one vacuum inlet at a time will reduce the air flow that is
required to effectively clean the carpets.
3. Hold inlet door open when removing hose.
After removing the hose from the inlet, hold the inlet door open for a few
seconds to make sure the unit has stopped and to clear any residual dirt out of
the ducting.
4. Do not pick up liquids.
Do not vacuum liquids into the vacuum ducting as any liquid left in the ducting
may cause major motor damage (not covered by warranty).
WARNING
• USEONLYGENUINEPREMIERCLEANSYNTHETICLINERBAGSWHICHPROUDLYDISPLAY
THEGENUINEPREMIERCLEANLOGO.
• WHENCHANGINGBAG,CHECKMESHUNDERBOTTOMPLATEFORLINTBUILD-UP,
CLEANIFREQUIRED.
DO NOT VACUUM PLASTER DUST, CONCRETE DUST, BRICK DUST, TALCUM POWDER
OR ANY LIQUIDS.
FAILURE TO COMPLY WILL VOID ANY IMPLIED WARRANTY.
ALL COMMERCIAL APPLICATIONS - 3 MONTH WARRANTY

8
BUY ONLINE
www.premierclean.com.au
Standard Hose & Tool Set
2 Way Brush
For use on carpets and vinyl/tiles.
Not recommended for floorboards, slate etc
Telescopic Wand
Adjustable to the height you desire, simply push the
button and extend to desired length.
Dusting Brush
Can be used just about anywhere.
Shelves, blinds, lamps, tables and window sills.
Upholstery Brush
This brush comes with removable brushes and
can be used on couches, curtains, rugs and mattresses.
Crevice Tool
Use for narrow spaces between couches,
window panes, hard to reach areas.
Please Note: Compact units do not come with upholstery brush
Accessories

9
BUY ONLINE
www.premierclean.com.au
1 YEAR WARRANTY
Switch on/off Hose & Tool Set also comes with
Hard Floor Brush
For use on any hard surfaces.
Floor boards, vinyl, slate, bricks and rugs.
Hose Hanger
Ideal to hang your hose on.
Switch Variable Hose
Control your unit from where you stand. Turn the unit on or
off or select from two suction levels. Turn the suction to low
for fine rugs and hard floor surfaces and turn the suction to
high for carpets. No more running back to the wall to turn
the unit off.
Optional extras Vac Socks to protect walls, accessory
hanger to hang your tools on and much more log onto
www.premierclean.com.au or 1300 881 608
for your nearest dealer.
Hose Sock - Available in 9mt and 12mtAir Driven Turbo Brush
Accessories

10
Troubleshooting
Problem Cause Action
Decrease
in suction
strength
Dirt recipient /
Bag is full
Emptydirtrecipient/changebag
Dirt recipient
is not properly
attached
Check clamps and dirt recipient is aligned
Filters need
cleaning /
replacing
Remove, shake
Motor guard
screen is
blocked
Remove filters, and check the guard screen
(which separates the motor from the filtration
compartment)forblockage.Ensurelters
are always properly installed, to prevent this
problem from happening again.
Open vacuum
inlet
Close all vacuum inlets not in use
Exhaustlineis
clogged
Verify that no object is blocking the exhaust
Blocked hose Plug the handle end of the hose into the
suction inlet, thus reversing the suction in the
hose. Cover the gap around the handle, to
ensure suitable suction strength, and ensure
contact with the inlet contacts to start the unit.
This should clear the hose
Obstruction
in the piping
system
Remove the pipe from the air intake connector,
to free the central vacuum unit from the piping
system. Start the unit by plugging the hose
into a vacuum inlet. By placing your extended
hand over the air intake opening on the unit,
check the suction strength on the unit itself.
If suction strength is normal, the obstruction
is in the piping system. If suction strength is
diminished or completely absent, have the unit
checked by an authorized service centre.

11
Troubleshooting
Problem Cause Action
Vacuum will
not start
The electrical power is
not connected properly
Ensurethatthepowercordis
plugged into a dedicated grounded
electrical outlet
Lowvoltagewirenot
connected properly
Verify the low voltage wires, make
sure they are properly inserted into
the low voltage inlet
Faulty vacuum inlet Start the vacuum unit from the other
inlets in your home, to identify the
defective inlet
Unit circuit breaker is off Press the reset button to reset the
unit circuit breaker. If unit restarts
and automatically shuts off shortly
after, contact an authorized service
centre
In-house circuit breaker
is off
Reset the circuit breaker in your
electrical panel. Verify that your
central vacuum unit is connected on
a dedicated grounded circuit
If none of these suggestions help start your vacuum unit,
contact your authorised service center.
www.premierclean.com.au
USE ONLY GENUINE PREMIER CLEAN SYNTHETIC FILTER BAGS.
FAILURE TO DO SO WILL VOID YOUR WARRANTY.
1300 881 608

12
Warranty Domestic Use Only
Monarch 490/550/650/850/950 & Premier 520/550/850 for a period of
60 months.
Monarch 250, Premier 250 and Premier 3000 for a period of 36 months.
Compact 1, Compact 2, Premier 200 and Typhoon units including Advanced
1700 and Typhoon 1700 for a period of 12 months from the date of purchase
against proven defects in workmanship and materials.
Premier Clean undertakes to exchange or repair any parts proven to be
defective within the relevant warranty period provided that the product has
not been modified, tampered with or repaired by any person other than an
authorised employee or dealer and has been used in accordance with the
instructions supplied.
THIS WARRANTY IS SUBJECT TO THE FOLLOWING CONDITIONS
Where the product was installed by an authorised Premier Clean dealer or
agent.
A) Labour and Parts
For a period of 90 days from the date of purchase the Premier Clean dealer
or agent who installed the product shall remove and repair or replace the
defective part free of charge, but any cost associated with travel outside the
metropolitan area is not included and shall be paid by the purchaser.
B) Parts Only
For the remainder of the relevant warranty period any defective parts will
be repaired or replaced if taken or delivered (inward and return freight pre-
paid) to Premier Clean. The cost of labour in respect of onsite repairs, removal
or re-installation by the Premier Clean dealer or agent shall be paid by the
purchaser.
Where the product was not installed by an authorised Premier Clean dealer
or agent, Premier Clean will repair or replace any defective parts if taken or
delivered (inward and return freight pre-paid) to a Premier Clean dealer or
agent. If the purchaser wants on-site repairs a service call charge shall be paid
by the purchaser.

13
General Exclusions
This warranty excludes normal wear and tear of certain parts such as filters,
damages caused by abusive use (eg: plaster dust, water, brick or concrete dust)
commercial use, lack of appropriate maintenance, inadequate installation,
negligence, natural disasters and acts of God.
Monarch and Compact Units
These units require synthetic filter bags to be used. Failure to use correct filter
bags will void your warranty. Premier Clean recommends the use of Premier
Clean filter bags only. Available from Premier Clean dealers, agents and
online.
Premier Bagless Systems
Premier Clean recommends bagless systems to be emptied every 2 months and
filter to be cleaned and replaced every 18 months to avoid lack of suction and
strain on electric motor.
Proof of purchase
Proof of purchase in the form of the product warranty card or invoice is a
condition of this warranty and without such proof this warranty shall not bind
Premier Clean.
No term of this warranty purports to exclude, restrict or modify the application
of any of the provisions of part V of the Trade Practices Act 1974 or part IV of
the Goods Act 1958 (Victoria).
If assistance is required in understanding the terms and conditions of the
warranty please contact Premier Clean or the dealer of where the product was
purchased from.

14
Notes

15
Purchase Receipt
Please Complete and Return by Post or visit us at
www.premierclean.com.au and complete online
Purchase Date
Model
Serial No.
(this is found on the top left hand side of the vacuum unit)
Dealer Name
Store/Address
Purchaser’s Name
Purchaser’s Address
Phone
For your future reference
Dealer Name
Dealer Phone Number
Address
Date of Purchase

Head Office
Factory 4/1 Merri Concourse,
Campbellfield, Vic 3061
PH: 1300 881 608
WEB:www.premierclean.com.au
E-MAIL:[email protected]
PremierCleanQueenslandWarehouse
Factory 1/13 Commerce Circuit,
Yatala,Qld4207
PH: 07 3382 6978
WEB:www.premierclean.com.au
E-MAIL:[email protected]
Factory 4/1 Merri Concourse,
Campbellfield, Vic 3061
!
Table of contents
Other Premier Clean Vacuum Cleaner manuals
Popular Vacuum Cleaner manuals by other brands

Electrolux
Electrolux ultraflex el4335b owner's guide

CTC Union
CTC Union Clatronic BS 1249 Instruction manual & guarantee

Hoover
Hoover Floormate Trio manual

Cleanmaxx
Cleanmaxx CP-CY4503ES-2 instruction manual

Neato Robotics
Neato Robotics BOTVAC D5 CONNECTED Trouble-shooting & FAQ

Tesvor
Tesvor R5 user manual