Check the frost on the cabinet liner surface, if find like following:
1) No frost, then do the leakage detecting.
A). If the leakage point is found, then first cut off the low pressure pipe to discharge
the left refrigerant in the system, then clean the pipe, replace with a new dry filter and
welding again, again recharge the refrigerant and do the leakage detecting.
B). If the leakage can not be found, cut off the low pressure pipe, if there is no
refrigerant omitting, then recharge the refrigerant and do the leakage detecting again; If
there is refrigerant omitting, cut off the high pressure pipe(means that compressor
suction is normal), charge the condenser pipe with pressurized nitrogen, if no air at low
pressure side, means the pipe is blocked, then replace the blocked parts and clean the
system pipe; If no air suction at compressor low pressure side, cut off the high pressure
pipe, means air compression of the compressor is not good, please replace the
compressor.
2).A little frost on the surface, also do the leakage detecting first.
A) If the leakage point is confirmed, then cut off the low pressure pipe, if a little
refrigerant air spurt out, means that the system leaks slowly on the leakage point, you
should repair the welding of cut pipe and the leakage point and clean the system pipe by
the high pressure nitrogen, replace the dry filter, after completion these work, re-vacuum
and recharge the refrigerant, at last do the leakage detecting again.
B). If big quantity refrigerant spurt out, cut off the high pressure pipe to check the
suction of the compressor low pressure pipe is normal or not: if no suction or weak
suction, it means not good compression and need to replace the compressor; if normal
suction, then charge the clean and warm nitrogen to the condenser pipe, if you find the
returned nitrogen of the low pressure side is not sufficient, it means that the system pipe
is clogged lightly, please replace the clogged parts and clean the pipe.
3). No frost, but have condensate water on the surface on the cabinet liner, check the
temperature of the high pressure side pipe and the compressor, you will find it is too high
temperature and check the low pressure pipe with frost, if like this, means too more
refrigerant in the system, please recharge with appropriate quantity refrigerant once
more.
4) The unit works discontinuously, maybe the system is clogged with ice, please replace
the dry filter and clean the system with clean and warm nitrogen.
5) Compressor doesn’t run.
Please check the electrical parts, such as PTC starter, capacitor, overload protector,
thermostat etc., if you find the parts go wrong, then replace a new one with same type
and specification. If all of these parts are good, please measure the resistance of the
compressor winding, if the resistance is abnormal, must replace the compressor;
otherwise check the overload protector act or not, means the over large current and
compressor goes wrong, also replace the compressor.