Procom 20UB100B-01 Series User manual

WARNING: Read and follow all warnings and instruc-
tions in this manual to avoid personal injury or property
damage.
INSTALLER: Leave these instructions with the owner
for future reference.
CONSUMER: Retain this manual for future reference.
FAN BLOWER ACCESSORY
FOR USE WITH
HEARTH GAS SPACE HEATERS
ASSEMBLY AND OPERATING INSTRUCTIONS
MODEL:
20UB100B-01 SERIES
20UB100B-01 / 20UB100B-01PC
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 7:30 am - 4:15 pm CST,
Monday through Friday or email customerservice@usaprocom.com

www.usaprocom.com 200285-01C2
ASSEMBLY AND OPERATION INSTRUCTIONS
DISCONNECTING WALL
MOUNTED HEATER
Wall mounted heater must be disconnected
from gas supply and removed from wall before
installing fan accessory. Contact a qualied
service person to do this. Follow all codes.
REMOVING PANEL FROM BACK
OF HEATER
If your heater has a knock-out panel, remove
panel at the four tabs with a Phillips head
screwdriver (see Figure 1). If your heater
has an installed panel, remove panel with a
screwdriver.
Panel
Fan/Blower
Assembly
On/Off Switch
Auto/O/Man Switch
Figure 2
Figure 1
Figure 3
FAN OPERATION
To operate in Manual mode, turn on/off switch
to the ON position. To operate in Automatic
mode turn AUTO/O/MAN to the desired posi-
tion, Man position will remain constantly on.
Auto position will be controlled by the sensor
on fan blower unit. To stop the operation, turn
unit switch to the O position (see Figure 3).
MAN O AUTO
ATTACHING FAN/BLOWER
ASSEMBLY
Attach fan/blower to the rear panel of the
heater using the four screws from step 2
(see Figure 2).
ELECTRICAL CONNECTION
Do not use this fan/blower if
any part of it has been under wa-
ter. Immediately call a qualied
service technician to inspect the
fan/blower and replace any part
of the electrical system which
has been under water.
This fan/blower accessory must be grounded.
This unit comes with a 3-prong grounding plug
for your protection against electrical shock.
Use standard, 3 holes, grounded outlet. If an
extension cord is needed it must have a 3
prong plug and a 3 hole receptacle. An under-
sized cord will cause a drop in live voltage and
could result in loss of power and overheating.

www.usaprocom.com 3200285-01C
ASSEMBLY AND OPERATION INSTRUCTIONS
Figure 5
ELECTRICAL WIRING
Any electrical re-wiring of this appliance must
be done by a qualied electrician. This wiring
must be done in accordance with local codes
and/or in Canada with the current CSA C22.1
Canadian Electrical Code, and for US instal-
lations, the National Electrical Code ANSI/
NFPA NO 70.
WARNING: If repairing or
replacing any electrical compo-
nent or wiring, the original wire
routing, color coding and secur-
ing locations must be followed.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger-
ous operation.
WARNING: Never attempt
to service fan/blower while it is
plugged in, operating, or hot.
Burns and electrical shock could
result. Only a qualied service
person should service or repair
fan/blower.
Verify proper operation after servicing. If any
of the original wire as supplied with the appli-
ance must be replaced, it must be replaced
with a wire of at least a 105º C temperature
rating.
Grounding Pin
Grounding Means
Metal Screw
Cover of
Grounded
Outlet Box
A
B
C
Adapter
Figure 4
Motor
Black
Green
White
Switch
Thermostat Switch
AUTO
O
MAN
FAN OPERATION
To operate the manual unit, turn ON/OFF
switch to the ON position. To operate the
Automatic unit, turn AUTO/O/MAN switch to
the desired position. MAN position will remain
constantly on. AUTO position will be controlled
by the sensor on the fan blower unit. The sen-
sor will be activated when the temperature of
the sensor head reaches the set point of the
switch after the heater is started. To stop the
operation, turn the switch to the O position.
GROUNDING INSTRUCTIONS
This fan/blower is for use on 120 volts. The
cord has a plug as shown at A in Figure 4.
An adapter as shown at C is available for
connecting three-blade grounding-type plugs
to two-slot receptacles. The green grounding
lug extending from the adapter must be
connected to a permanent ground such as
a properly grounded outlet box. The adapter
should not be used if a three-slot grounded
receptacle is available.

200285-01
Rev. C
10/16
WARRANTY
KEEP THIS WARRANTY
Model _______________________________
Serial No. ____________________________
Date Purchased _______________________
Keep receipt for warranty verication.
REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COM
IMPORTANT: We urge you to register your product within 10 days of date of installation, complete
with entire serial number which can be found on the rating plate. Please ll out the warranty infor-
mation above for your personal records. Retain this manual for future reference.
Always specify model and serial numbers when communicating with customer service.
We reserve the right to amend these specications at any time without notice. The only warranty applicable
is our standard written warranty. We make no other warranty, expressed or implied.
LIMITED WARRANTY
ProCom Heating, Inc. warrants this product to be free from defects in materials and components for ONE
(1) year from the date of rst purchase, provided that the product has been properly installed by a qualied
installer in accordance with all local codes and instructions furnished with the unit, operated and main-
tained in accordance with all applicable instructions. To make a claim under this warranty, the Bill of Sale
or cancelled check must be presented.
RESPONSIBILITY OF OWNER
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s)
required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through
ProCom Heating, Inc. who will provide original factory replacement parts. Failure to use original factory
replacement parts voids this warranty.
IMPORTANT: The heater MUST be installed by a qualied installer in accordance with all local codes
and instructions furnished with the unit or the warranty is voided.
WHAT IS NOT COVERED
This warranty does not apply to parts that are not in original condition because of normal wear and tear or
parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects
caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other
costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES. INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1)
YEAR ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE. PROCOM HEATING, INC.'S
LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND PROCOM HEAT-
ING, INC. SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT.
INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
accidental or consequential damages, the above limitation on implied warranties, or exclusion or limitation
on damages may not apply to you.
This warranty gives you specic legal right, and you may also have other rights that vary from state to state.
ProCom Heating, Inc.
Bowling Green, KY 42101
www.usaprocom.com
1-866-573-0674
This manual suits for next models
2
Popular Fan manuals by other brands

Hunter
Hunter 21778 Parts guide

Milcor
Milcor Big Smoky Installation and maintenance instructions

Fanimation
Fanimation Air Shadow FP820 Series Specification sheet

Westinghouse
Westinghouse 72421 Important instructions

KDK
KDK K15V0 Operating and installation instructions

Greenwood
Greenwood Airvac P1 installation instructions