manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ProStart
  6. •
  7. Data Logger
  8. •
  9. ProStart PROTRAINING 2.0 User manual

ProStart PROTRAINING 2.0 User manual

Introduction : You’ve just acquired a Protraining 2.0 timing system and we thank you for
your trust. We recommend to closely read the entire manual in order to understand the
cabability of your amazing timing system.
PROTRAINING 2.0 MANUAL
PRO-ST1 PRO-ST2 PRO-ST3
1 black & blue case to put all the equipments away
1 ST-BOX, the Bluetooth 4.0 device
1 cable extension of 60m / 200ft on drum
1 cable extension of 2m / 6,5ft with orange connectors
1 beam sensor on tripod
1 reflector on tripod
1 cable ext. 1.8m/6ft with black connect.
2 beam sensors on tripod
2 reflectors on tripod
2 cable ext. 1.8m/6ft with black connect.
1 ST-BAT (12Vdc 1.2Ah Battery)
1 battery charger 12Vdc
3 beam sensors on tripod
3 reflectors on tripod
3 cable ext. 1.8m/6ft with black connect.
1 ST-BAT (12Vdc 1.2Ah Battery)
1 battery charger 12Vdc
PROSTART
288, Rue du Radar
17220 Sainte-Soulle
France
www.prostart-bmxgates.com
www.vimeo.com/prostart/
www.facebook.com/PROS TART.BMX quentin.grun@prostart.fr
(+33) 689 044 061
Warranty :
The Protraining 2.0 is guaranteed for a period of one year. Any product returned within the
warranty period will be exchanged by a new one. ProStart excludes all liability for loss,
damage or delay of goods when sent by a carrier.
Products excluding warranty will be subject to a repair estimate.
Any product returned will be subject to an agreement by Prostart
Setting up your Protraining 2.0 on your starting system :
PROBOX (Prostart starting system) OR PROADAPTER (Adaptor in order to use the product from any starting systems)
1/ Connect the cable extension of 2m /6.5ft from the starting system or adapter (femelle plug) to the
ST-BOX Bluetooth device. (male plug)
If you don’t have any plug on your starting system, please contact us through Quentin.grun@prostart.fr
2/ Connect the cable extension of 60m / 200ft on drum to the FINAL SENSOR plug on the ST-BOX.
3/ Take out protective covers to open tripods and adjust them at the height of your choice.
4/ Supply sensor(s) in connecting the cable extension(s) of 0.6m / 2ft
5-A/ If you have only one sensor, connect it to the cable extension of 60m / 200ft on drum.
connect the second one to the cable extension of 60m / 200ft on drum.
Setting up your Protraining 2.0 on independent mode :
1/ Connect the cable extension of 2m / 6.5ft from the ST-BOX Bluetooth device (male plug) to the ST-BAT
(female plug).
2/ Connect the cable extension of 60m / 200ft on drum to the ST-BOX Bluetooth device (FINAL SENSOR plug).
3/ Take out protective covers to open tripods and adjust them at the height of your choice.
4/ Supply sensor(s) in connecting the cable extension(s) of 0.6m/2ft
to the cable extension of 60m / 200ft on drum.
the ST-BOX(SPLIT SENSOR plug) and also connect the third one to the cable extension of 60m / 200ft on drum.
How to set up the sensor(s) ?
Each sensor needs to be supplied. You can notice it when the the green indicator is switched ON.
Orange indicators are switched ON, it means that your system is ready to be used.
Safety instructions :
- Do not walk/ride on cables.
- Hand tighten all the connectors, control knobs and pan handles only.
- Remove dust, dirt & water from the sensor before each utilisation.
1/ Download our App’on Google Play & Apple Store : PROSTART
2/ Click on 2S TIMING and Capture buttons and then click on the Bluetooth Logo to link your device with the
ST-BOX. Name of the Bluetooth device will be STBOX-xxxxx
3/ You can now measure, save and analyse all your times.
How to link the Protrainig 2.0 timing system to the PROSTART Application ?
FINAL SENSOR
CABLE EXTENSION
SPLIT SENSOR
ST-BOX
START
SENSOR
STARTING
SYSTEM
ST-BAT

This manual suits for next models

3

Popular Data Logger manuals by other brands

hager HTG410H operating manual

hager

hager HTG410H operating manual

YOKOGAWA SMARTDAC+ GM technical information

YOKOGAWA

YOKOGAWA SMARTDAC+ GM technical information

Gallagher HR4 instructions

Gallagher

Gallagher HR4 instructions

Onset Computer Corporation StowAway-IS Temp user manual

Onset Computer Corporation

Onset Computer Corporation StowAway-IS Temp user manual

Efento BLE user manual

Efento

Efento BLE user manual

Point Mobile PM451 user manual

Point Mobile

Point Mobile PM451 user manual

Hioki LR8400-20 Measurement guide

Hioki

Hioki LR8400-20 Measurement guide

Omega OM-DLAV instructions

Omega

Omega OM-DLAV instructions

UEi THL2 instruction manual

UEi

UEi THL2 instruction manual

GREISINGER EASYLog 40NS W operating manual

GREISINGER

GREISINGER EASYLog 40NS W operating manual

Fluke 2638A user manual

Fluke

Fluke 2638A user manual

MadgeTech X Series Product user guide

MadgeTech

MadgeTech X Series Product user guide

AEMC Simple Logger II user manual

AEMC

AEMC Simple Logger II user manual

Beko METPOINT OCV Instructions for installation and operation

Beko

Beko METPOINT OCV Instructions for installation and operation

ADLINK Technology DAQ-2010 user guide

ADLINK Technology

ADLINK Technology DAQ-2010 user guide

NexSens X2 manual

NexSens

NexSens X2 manual

MadgeTech RTDTemp2000 manual

MadgeTech

MadgeTech RTDTemp2000 manual

Axiometrix Solutions imc CRONOS-SL Getting started

Axiometrix Solutions

Axiometrix Solutions imc CRONOS-SL Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.