3.3 Output of loop frequency
Approx. 1 sec. after calibration of the detector the loop frequency will be
displayed by pulse signals of the green LED. Firstly the 10 kHz position
of the frequency value will be indicated. For every 10 kHz frequency
value once. After a break of 1 sec the 1 kHz
position is displayed in the same manner. If there is value of '0' in the 1
kHz position there will be hes for 1 kHz
position are a little bit shorter than for the 10 kHz position.
Example for 57 kHz loop frequency:
5x 10 kHz 7x 1 kHz
1sec
tenth values single values
4 Safety information and warnings
The device should only used for the applications described by the
manufacturer.
Please keep this operation instruction always accessible and hand it
over to every user.
he device, use of repair parts and
supplementary equipment which are not sold or recommended by the
manufacturer can cause burning, electric shock and injuries.
Therefore the manufacturer has no liability and this excludes all
demands of warranty.
The warranty regulations of the manufacturer are valid in the version
of the purchase date for that device. There is no liability for not
suitable, wrong manual or automatic adjustments also regarding no
suitable applications of the device.
Repairs may only made by the manufacturer.
The he requirements for SELV and
limited power sources according to EN 60950-1.
All connections, the start-up, maintenance, measurements and
adjustment operations to the detector have to be made from electrical
specialists who have special know-how in the prevention of accidents.
For the use of devices which have contact to electrical power, please
pay attention to the valid security instructions and all prevention
nd accidents.
All operations with the device and its placement have to be done in
accordance with national and general electrical instruction orders.
The user is responsible for an installation, which has conformity to all
technical rules in the country where the device is mounted, and also
to all regional valid orders. For that the dimension of cabling, fuse
nection, isolation
controlling and the protection for overload current have to be regarded
in detail.
The detector can not be used as a security device regarding to the
security instructions of electrical machines. Using in systems with high
danger potential it is necessary to include additional protection
devices!
5 Technical data
Dimensions 79 x 22,5 x 90 mm (h x w x d without plug)
Protection class IP 40
Power supply 24 V AC/DC 10 % max.1,5 W SELV
Operating
temperature
-20 °C to +70 °C
Storing
temperature
-20 °C to +70 °C
Humidity max. 95 % not condensing
Loop inductivity 25- 800 µH, recommended 100 -300 uH
Frequency range 25-130 kHz in 2 steps
Sensitivity 0,01 % up to 0,65 % ( f/f) in 4 steps
0,02 % up to 1,3 % ( L/L)
Hold time 5 minu
Loop lead length max. 250 m
Loop resistance max. 20 Ohm (incl. loop lead)
Relays
presence relay
pulse relay
250 mA / 24 V AC/DC (min. 1 mA/5 V)
contact n.c. (adjust. operation principle)
contact n.o.
Signal duration > 200 ms
Cycle time 40 ms (reaction time 80 ms)
Connections screw terminals (power supply, relays)
binder plug (loop connection)
6 Connections
82V0 V42
5261 51
frequency high
frequency low
sensitivity
hold time
relay operation principle
~ / = V 4 2
0V/GND
presence signal pulse signal
r
h
s
5'/oo
/
VEK M1H
www.proteco.net
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY
7How to make the loops
The loops must be constructed at least 15 cm from fixed metal objects,
at least 50 cm from moving metal objects, and at no more than 5 cm
from the surface of the definitive flooring.
Use a normal single-pole 1,5 mm² diameter cable (if the cable is buried
directly, il must be double insulated).
Make a loop, preferably square or rectangular, using a PVC raceway
or making a chase in the floor as shown in the figure at the side
(corners should be cut at 45° to prevent the cable from
fracturing). Lay the cable, with the number of windings indicated in the
table.
The two cable ends must be intertwined (at least 20 times per
meter) from the loop to the detector.
Do not make any joints on the cable (if this is necessary, solder the
conductors and seal the joint with a heat-shrink sheath) and keep it away
from mains power cables.
Loop perimeter number of windings
less than O
fromto 4 m.
from4to 6 m.
from6to 12 m.
over 12 m.
6
5
4
3
2