SERIES 54000
Spring Loaded Pressure Vent
INSTALLATION PROCEDURE:
1. Unpack unit. Inspect carefully to make sure that all
packing material, protective car boar , tape an flange
protectors are remove .
2. The vent shoul be lifte by the multiple lifting lugs only.
Do not lift by attachment to weatherhoo or flange. Care
shoul be taken to avoi amage to unit as it is being
positione in its mounting location.
3. The vent setting is establishe at the factory per or er
specifications. No mo ifications or a justments are
require prior to vent installation.
4. Mount vent to the appropriate flange using gaskets
compatible with service con itions. For best perform-
ance, the vent shoul be mounte level so that the seat-
ing surface is no more than 1° off horizontal.
MAINTENANCE:
Protectoseal recommen s that our pro ucts be inspecte an
maintaine accor ing to the normal maintenance sche ule of
the facility. At a minimum, maintenance shoul be con ucte
annually. More frequent maintenance may be require , an
shoul be sche ule , for unusual service con itions.
CAUTION: When maintaining any Protectoseal
device, the legal, corporate and advisory safety
regulations and procedures appropriate for the
specific installation site must be fully understood
and followed.
CAUTION: Tan vapor space pressure or vacuum
should be relieved before any maintenance
operations are underta en.
MAINTENANCE PROCEDURE:
1. Remove the lifting lugs from the stu s. Remove hoo
nuts an weatherhoo from vent. Remove the screen.
NOTE: No spring forces are involve uring these
processes.
2. Inspect vent an remove any loose irt or foreign
material from the unit or the hoo . Inspect the screen
an replace if amage .
3. The vent is esigne so that all spring forces are
containe by the spring package. The springs are com-
presse between the flange plate an upper spring
gui es (see Detail A).
WARNING: If it is necessary to disassemble
the spring pac age, extreme caution must be
exercised due to the high spring forces that
may be present within the spring pac age
assembly.
www.protectosea .com
PROTECTOSEAL®
CAUTION:
If any questions arise concerning the proper insta ation
or maintenance of our products, p ease contact
Protectosea or one of our Authorized Representatives.
When insta ing any Protectosea device, the ega ,
corporate and advisory safety regu ations and
procedures appropriate for the specific insta ation site
must be fu y understood and fo owed.
Ve t Li e / I -Li e Parallel Plate
Flame Arrester is desig ed for
i stallatio i ope ve t pipe or
bleed li es from storage or pro-
cessi g ta ks. Suitable for NEC
Group D (IEC Group IIA) vapors
Combi atio Pressure / Vacuum
Relief Ve t & Flame Arrester
provides pressure a d vacuum
relief as well as protectio from
propagatio of exter ally i tro-
duced flames. Suitable for NEC
Group D (IEC Group IIA) vapors.
Emerge cy Ve t protects ta ks
agai st rupture or explosio
resulti g from excessive
i ter al pressure caused by
exposure to fires.
Series 4950 Series 830
Series 7800
Pipe-Away Pressure Vacuum
Relief Ve t for applicatio s that
require hazardous vapors be
processed i to ma ifolded
pipi g a d ot released i to the
atmosphere
Series 18540
Ins alla ion & Main enance Series 54000
Spring Loaded Emergency Pressure Vent
ADDITIONAL PRODUCTS FROM PROTECTOSEAL
©2012 The Protectosea Company VM-54000/1
PROTECTOSEAL®
Safety Without Compromise
225 Foster Ave., Bensenville, IL 60106-1690
P630.595.0800 F630.595.8059
[email protected] www.protectoseal.com
Spring Pac age Disassembly & Reassembly
Measure the compresse height of the springs in the spring
package (See Detail A) an recor this imension for later
use.
NOTE: This compressed spring height is critical in
that it establishes the set point of the vent.
1. The stu s on the vent are long enough so that all com-
pressive force of the springs can be relieve as spring
nuts are loosene . As the nuts are loosene , the spring
gui es will move upwar s, relieving spring forces. The
spring nuts shoul be loosene alternately an evenly so
that each of the springs are allowe to expan evenly
until the free length of the springs is reache .
2. Once the spring forces have been relieve , the spring
nuts, spring gui es, springs an pallet assembly may be
remove for inspection.
3. Inspect the iaphragm. If the iaphragm is eteriorate it
shoul be replace . Make sure that the nut securing the
iaphragm is fastene securely.
4. Inspect the seating surface. It shoul be smooth an free
of irt or nicks. If necessary, clean the seating surface
with an appropriate cleaner or solvent.
CAUTION: Do not use a file or sharp tool that
may damage the seat surface.
5. Reassemble the spring package assembly in the reverse
or er to above. Install pallet assembly, lower spring
gui es, springs, upper spring gui es an spring nuts.
Slowly compress the springs by tightening the spring
nuts evenly an alternately until the springs are at their
compresse height that was measure in Step 1 of this
process.
NOTE: This compressed spring height is criti-
cal in that it establishes the set point of the
vent.
6. Tighten spring nuts to secure position of spring plate.
7. Reinstall the screen, weatherhoo , hoo nuts an lifting
lugs.
888.858.3647 | relevantsolutions.com
Distributed by:

Popular Fan manuals by other brands

Johnson 2X Instructions for use

Johnson

Johnson 2X Instructions for use

Hardware House 162272 Owner's instruction manual

Hardware House

Hardware House 162272 Owner's instruction manual

Oceanic OCEAVC78CMW3 user manual

Oceanic

Oceanic OCEAVC78CMW3 user manual

Derale 16927 installation instructions

Derale

Derale 16927 installation instructions

Harbor Breeze MAZON MZ44MBLK3LR manual

Harbor Breeze

Harbor Breeze MAZON MZ44MBLK3LR manual

Vostermans Ventilation Multifan 130 installation instructions

Vostermans Ventilation

Vostermans Ventilation Multifan 130 installation instructions

Hunter Saturn 90058 Parts guide

Hunter

Hunter Saturn 90058 Parts guide

ZEN HOME J42003-XY-1L Installation instruction

ZEN HOME

ZEN HOME J42003-XY-1L Installation instruction

Hunter 20552 Parts guide

Hunter

Hunter 20552 Parts guide

Komfovent VERSO Pro S Installation and maintenance service manual

Komfovent

Komfovent VERSO Pro S Installation and maintenance service manual

ViM JBRB ECOWATT PR instruction manual

ViM

ViM JBRB ECOWATT PR instruction manual

Levante LEV16MPF Operation manual

Levante

Levante LEV16MPF Operation manual

Xpelair C6R Installation and maintenance instructions

Xpelair

Xpelair C6R Installation and maintenance instructions

KDK 23BWDBH Installation and operating instructions

KDK

KDK 23BWDBH Installation and operating instructions

Komfovent VERSO Pro S Installation and maintenance service manual

Komfovent

Komfovent VERSO Pro S Installation and maintenance service manual

Lasko W09550 Important instructions & operating manual

Lasko

Lasko W09550 Important instructions & operating manual

Visual Comfort & Co. Maverick 3MAVR70AGPD manual

Visual Comfort & Co.

Visual Comfort & Co. Maverick 3MAVR70AGPD manual

Biddle Innovair Size 3 Installation, operation & maintenance instructions

Biddle

Biddle Innovair Size 3 Installation, operation & maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.