manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Protectwell
  6. •
  7. Security System
  8. •
  9. Protectwell PTW-3300S User manual

Protectwell PTW-3300S User manual

PTW-3300S
Intelligent Touch Screen Addressable Fire Alarm System
The PTW-3300S is a powerful intelligent networkable touch
screen color display fire alarm controller designed with many
levels of flexibility to meet virtually any application. Features such
as fire detection & alarm, networking and graphical workstations
allow this modular solution to accommodate the simplest systems
up to the most complex solutions.
With one to sixteen Signaling Line Circuits (SLCs), the
PTW-3300S supports up to 3,168 intelligent addressable devices
when it connects with PW-600P or PW-330DP Series detectors,
up to 2,544 intelligent addressable devices when it connects with
PW-300P Series detectors.
Information is critical to fire evacuation personnel, and the
PTW-3300S's large 1024x600 pixel touch screen Liquid Crystal
Display (LCD) presents vital information to operators concerning a
fire situation, fire progression, and evacuation details.
A host of other options are available, including LED, LCD, LDM, or
PC based graphic annunciators; fire or integration networking;
advanced detection products for challenging environments, and
many additional options.
General
PTW-3300S B (left) and PTW-3300S C (right)
SE-190731-Z
www.protectwell.com
Page 1 of 4
Features
One to sixteen isolated intelligent Signaling Line Circuits (SLC)
Style 4, 6 or 7.
With PW-330DP and PW-600P series, up to 99 detectors
(photo, thermal) and 99 modules or any configuration of 198
devices per SLC. 198 devices per loop/3168 per FACP or
network node.
With PW-300P series, up to 159 intelligent devices per
loop/2544 per FACP or network node.
large 1024x600 pixel touch screen displays with user friendly
menu.
English, and Chinese language support.
Connect to the Graphical Workstations (Proworkse-3S) for
centralized management.
Network option–supports PTW-3300S, PW-NCA-3S Network
Annunciator, or Proworkse-3S Network workstations. Up to 99
network Nodes.
P-VFT-3S Tools online/offline program option.
Application code is saved in Flash memory, eliminating the
need to change EPROMs.
RS-232 output for remote system printer.
40,000-event capacity for each type. Automatically records the
latest fire alarms, faults and system events, and stores in a
classified manner to facilitate query.
Advanced history filters allow sorting by event, time, date.
Field-programmable on PC or controller.
Non-alarm points for lower priority functions.
Support remote offline programming, LAN and WAN remote
debugging.
Multiple network ports and interface:RJ45, RS232,
RS485, CAN Bus.
Program keypad: Alphanumeric keypad and Virtual full
QWERTY keypad.
15 LED indicators: Power; Battery; Fire Alarm; Linkage;
Delayed start; Supervisory; Point Disabled; System Failure;
Feedback; Trouble; Signals Silenced; Self-test.
LARGE 1024*600 PIXEL TOUCH SCREEN DISPLAY
FEATURES
Sample System Options
www.protectwell.com
Page 2 of 4
Intuitive and secure configuration software that makes
complex programming and service easier than ever
Firmware upgrades in the field, so the system will never
become outdated
Expanded system event reporting from front panel, without
the need for a computer
Keypad Program Edit.The PTW-3300S, has the exclusive
feature of program creation and editing capability from the
Virtual full QWERTY panel keypad, while continuing to
provide fire protection.
Drift Compensation and Smoothing. Drift compensation allows to
compensate the sensitivity drift of the system caused by slow
environmental changes such as temperature, humidity and dust
that are external non-fire factors and to retain its original ability to
detect actual smoke, and resist false alarms. Smoothing feature is
also provided for the sample data to remove interference and
noise effectively.
Reliable self-diagnostics and protection. The controller can
periodically perform self-test on the detector and the module.
When the component is damaged or the accumulated dust of the
detector is about to reach or exceed the allowable limit, a fault
alarm is issued, which greatly improves the reliability of the
system.
Sensitivity Adjust. With Nine-level alarm sensitivity, the sensitivity
of each detector can be adjusted as needed which greatly
facilitates system debugging and routine maintenance.
Intelligent Sensing
Field Programming Options
PTW-3300S
Intelligent Touch Screen Addressable Fire Alarm System
SE-190731-Z
P-VFT-3S Offline Programming Software
P-VFT-3S Tools is an offline programming and test utility that can
greatly reduce installation programming time, and increase
confidence in the site-specific software. It is Windows® based
and provides technologically advanced capabilities to aid the
installer. The installer may create the entire program for the
PTW-3300S in the comfort of the office, test it, store a backup file,
then bring it to the site and download from a laptop into the panel.
And realize offline programming by USB/SD card, to achieve
system setting, linkage data, loop data modification and system
upgrade.
CONFIGURATION GUIDELINES
Stand-alone and network systems require a main display. On
single FACP systems (one PTW-3300S), the display option is the
PW-CPU-3S. On network systems (two or more networked fire
panel nodes), at least one NCA, or Proworkse-3S workstation
annunciation device is required. Options listed as follows.
MAIN SYSTEM COMPONENTS
PW-CPU-3S: PTW-3300S Primary Display. PW-CPU-3S ships
with keypad/display installed; includes 1024x600 pixel touch
screen backlit LCD display, Virtual full QWERTY programming and
control keypad. PW-CPU-3S is a central processing unit and
requires an MPS-350W-3S power supply.
LCM-3S: Loop Control Module. Provides two SLC. PTW-3300S
supports up to eight LCM-3Ss. one LCM-3S module supports two
loops, need to be used with the interface board LCM-EX.
LCM-EX: Loop Control Module Interface Board. 1 piece interface
board can be connected to 4 pieces loop control modules, more
than 4 pieces loop cards are required to use 2 pieces interface
boards. Up to 2 pieces interface boards.
POM-32S:Up to 32 nodes per Multi-Line Linkage Control
Module, includes plate and membrane, need to be used with
POM-3S. 1pc POM-32S can connect 4pcs POM-3S output cards.
3 types of status indicators(Output, Feedback,Fault).
POM-3S:Multi-Line Linkage Output Card; 4 channels, each
channel contains 1 output and 1 channel of monitoring, with line
monitoring function, need to be used with POM-32S. Up to 8
pieces POM-3S.
CONFIGURE SYSTEM: For Four-loop PTW-3300S with display:
PW-CPU-3S, two LCM-32Ss, LCM-EX, (POM-32S,
POM-3S,DP-1B-3S, options), MPS-350W-3S, SBB-B-3S.
NETWORKING OPTIONS
PW-NCA-3S: Network Control Annunciator. An alternate primary
display for PW-CPU-3S can be provided by the PW-NCA-3S,
Proworkse-3S. On network systems (two or more networked fire
panel nodes), one network display (either PW-NCA-3S,
Proworkse-3S) is required for every system. need to order
backbox (3S-NCA-SBB) separately.
Proworkse-3S: Graphics PC workstation, Proworkse-3S GUI
software, and USB Dongle.
PW-GW-L/LRM (PW-GW-L/LRM2/PLUS): LoRa Gateway.
AUXILIARY POWER SUPPLIES AND BATTERIES
MPS-350W-3S: One power supply and two 12V24AH
batteries are required for each PTW-3300S.
COMPATIBLE DEVICES, EIA-485 PORTS
LCD-8800: Floor Liquid Crystal Display annunciator.
LDM-64-3S:Lamp Driver Annunciator Control Module. For
use with custom graphic annunciators. 64 Points.
LDM-E64-3S:Lamp Driver Annunciator Expander module.
For use with custom graphic annunciators. 64 Points.
LPI-MODBUS-3S:Modbus Network Card. Used to integrate
third-party system information or output linkage signals to
third parties(Includes LPI-MODBUS-3S hardware and plug-in
software).option.
GW-MODBUS-3S:Modbus Network Card. For third-party
systems, information integration interface for FAS systems,
(Includes GW-MODBUS-3S hardware and plug-in software),
option.
COMPATIBLE INTELLIGENT DEVICES
PW-300P: Low-profile photoelectric detector.
PW-300PT: Low-profile photoelectric detector with 135°F
(57°C) thermal.
PW-300T: thermal detector 135°F (57°C).
PW-300TR: thermal detector 135°F (57°C) with rate-of-rise.
PW-300APT: Acclimate Plus™ low-profile multisensor
detector.
PW-330DP:Low-profile CLIP photoelectric detector.
PW-330DT:Low-profile CLIP Thermal Detector, Fixed
Temperature.
JTW-BCD-PW-330DT:Low-profile CLIP Thermal Detector,
Fixed Temperature and Rate of Rise Combination.
PW-600P: Intelligent Photoelectric Smoke Detector.
PW-600T: Intelligent Thermal Detector.
JTY-GD-PW-600PM: Intelligent Photoelectric Smoke
Detector.
JTW-BD-PW-600TM: Intelligent Thermal Detector.
B224RB: Low-profile relay base.
B224BI: Isolator base for low-profile detectors.
B501: 4" (10.16 cm) base.
P301BH: Sounder Base for 300P Series
B500BH-3: Loop-powered Sounder Base
B200S: Intelligent programmable sounder base, capable of
producing a variety of tone patterns including ANSI Temporal
3. Compatible with synchronization protocol.
B200SR: Sounder base, Temporal 3 or Continuous tone.
B900BI:Isolator Base for 330DP Series.
B900BH:Intelligent sounder base for 330DP/600PM/600TM
Series.
www.protectwell.com
Page 3 of 4
PTW-3300S
Intelligent Touch Screen Addressable Fire Alarm System
SE-190731-Z
B900BH-3: Loop-powered Sounder Base for 330DP/600PM
/600TM Series.
P330BH: Multi-function Detector Base for 330DP/600PM /600TM
Series.
P601: Detectors Base for 600P series
P901E: Detectors Base for 330DP series.
PMM-3: monitor module.
PMM-3P: two-wire detector monitor module for 300DP series.
PMM-303: miniature monitor module.
PCM-3: control module.
PRM-3: relay module.
M500DMR1: dual monitor/dual relay module.
M500K: Resettable Manual Call Point for 300P series.
BBS-2: MCP Wall Mount Back Box.
PISO-3: Isolator module for 300P series.
M501X: Mini Loop Isolator Module for 300P series.
PCM-3C: Control module.
PMM-3C: Relay module.
JSKM-PCM-3D: Input-Output Module, 24VDC.
PMM-3CP: Addressable 2-Wire Detector Monitor Module for
330DP series.
PISO-3E: Isolator module for 330DP series.
M330K: Addressable Manual Call Point for 330DP series.
PMM-6: Intelligent Monitor Module.
PMM-6P: Conventional Detector Interface Module.
PCM-6: Intelligent Control Module.
PCM-6D: Intelligent Input-Output Module.
PISO-6: Isolator Module.
M600K: Intelligent Manual Call Point with Phone Jack.
BBS-X: Manual Call Point Backbox.
PW-LED-01: Remote LED Indicator.
ENCLOSURES, CHASSIS, AND DRESS PLATES
PTW-CAB Series Enclosure: PTW-3300S mounts in a standard
PTW-CAB Series enclosure (available in two sizes, “B”and “C”).
Backbox with door together.
SBB-B-3S(R):Backbox; 2 chassis, black. “R”means red.
SBB-C-3S(R):Backbox;3 chassis, black. “R”means red.
DP-1B-3S: Dress Plate. Provides dead-front panel for unused
tiers; covers POM-32S.
System Specifications
SYSTEM CAPACITY
Intelligent Signaling Line Circuits...1 expandable to 16
Intelligent detectors and modules (300P series) 159 devices
per loop
Intelligent detectors and modules (330DP/600P series)198
devices per loop
SPECIFICATIONS
Operation Temperature: 0 - 40℃
Operation Humidity: ≤95% RH, non-condensing
Main Current: AC 220V 50 ± 1% Hz +/-15%
DC Standby Current: DC 24V 24Ah
Output Current & Voltage: Two 10A/27V
One 3A/5V
Quiescent Dissipation: 220V 120mA
AGENCY LISTINGS AND APPROVALS
These listings and approvals apply to the modules specified
in this document. In some cases, certain modules or
applications may not be listed by certain approval agencies,
or listing may be in process. Consult factory for latest listing
status.
CCCF listed.
STANDARDS
The PTW-3300S is Listed and approved with the following
CCCF Standards:
GB4717-2005 Fire Alarm Control Units and GB16806-2006
Automatic Control System for Fire Protection.
www.protectwell.com
Page 4 of 4
PTW-3300S
Intelligent Touch Screen Addressable Fire Alarm System
SE-190731-Z

Popular Security System manuals by other brands

Optex Morse MDC 16 ETX user manual

Optex Morse

Optex Morse MDC 16 ETX user manual

Nokia EM5400 installation guide

Nokia

Nokia EM5400 installation guide

Siemens IC60 user manual

Siemens

Siemens IC60 user manual

STL VIREO S-VR100 instruction manual

STL

STL VIREO S-VR100 instruction manual

ADEMCO VIA-30PSE installation instructions

ADEMCO

ADEMCO VIA-30PSE installation instructions

Risco SecuSafe EL4855PI quick start guide

Risco

Risco SecuSafe EL4855PI quick start guide

ESP CanCam quick guide setup

ESP

ESP CanCam quick guide setup

GST I-9407 quick start guide

GST

GST I-9407 quick start guide

Paradox SAFE PROTECTOR 950 instructions

Paradox

Paradox SAFE PROTECTOR 950 instructions

First Alert FA168C-CN user guide

First Alert

First Alert FA168C-CN user guide

Texecom PREMIER 640 Quick reference guide

Texecom

Texecom PREMIER 640 Quick reference guide

Bosch DIVAR IP 7000 2U Quick installation guide

Bosch

Bosch DIVAR IP 7000 2U Quick installation guide

PreView WS6010 operating manual

PreView

PreView WS6010 operating manual

ELRO CBFS58R-01 instruction manual

ELRO

ELRO CBFS58R-01 instruction manual

teko Astra-Z-6145 operating manual

teko

teko Astra-Z-6145 operating manual

Swann Alert DVR Camera Kit quick start guide

Swann

Swann Alert DVR Camera Kit quick start guide

Visonic PowerMax Partitions II Quick installation guide

Visonic

Visonic PowerMax Partitions II Quick installation guide

ITS Telecom EKSELANS BP-1 user manual

ITS Telecom

ITS Telecom EKSELANS BP-1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.