Safeline SL6+ User manual

SafeLine
SL6+
10.2017
241
229
160
47
2 x 5,5
2 x 9,5
www.safeline-group.com
MANUAL
SL6+ v2.04 EN
Lift emergency telephone
Complies to EN 81-28 and EN 81-70 standards.
PATENT 08163634.2

2
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SafeLine
SL6+
SL6+ v2.04 EN
TECHNICAL DATA MAIN UNIT
Power: Supply voltage: 230 VAC min: 6,4 W, max: 9,4 W
Battery: Battery voltage: 12 VDC lead battery
Capacity: 1,2 Ah
Charge: 13,65 VDC, max. 200 mA
Emergency light: Emergency light output: 12 VDC max 500 mA
Emergency signal: Acoustic emergency signal output: 12 VDC max 200 mA
Inputs: 10-30 VDC, 5 mA, optically isolated
Antenna connector type: SMA (female)
Size: 241 x 160 x 47 mm (L x W x H)
Weight: 1,7 kg
Relay outputs: Max 1 A/30 VDC, potential free relay outputs
IP code: IP20
Soundfiles: 16 sec/file
Bluetooth: Bluetooth 4.0
BLE 2,4 GHz
TECHNICAL DATA BUS UNIT
Power: Supply voltage: 12 VDC, current drain nominal 15 mA
Inputs: 10-30 VDC, 5 mA, optically isolated
Pictogram outputs: Max 100 mA, 24 VDC, transistor outputs, open collector
IP code: COP-unit: IP00
COP2, Surface- or flush mounted units: IP40
To reach safety level IP4X, suitable additional protection have
to be installed onsite.
OTHER TECHNICAL DATA
Max cable length: 0,22 mm2cable: 100 m
0,75 mm2cable: 250 m
Operating temperature: 0º - 70º C
Interface Board: *SL6-GSM-BOARD:
- Micro SIM,
15 x 12 x 0,76
mm
- Supports 2G
- Requires SW 3.40 or later
*IF-BOARD-4G:
- Micro SIM, 15 x 12 x 0,76 mm
- Supports 2G, 3G and 4G
- Requires SW
4.45
or later
TÜV REGISTRATION NUMBER 01/208/FWB/164/1204/5003

3
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
TÜV 43
SL6+ v2.04 EN
Battery function 39
Troubleshooting main unit 40
Troubleshooting bus unit 41
Related test procedures 42
SERVICE
Calling with SafeLine SL6+ 33
Intercom between main station and bus unit
34
Outgoing call 34
Emergency calling process 35
Incoming call process 36
Fallback 37
Fire mode 38
OPERATING
Connect 18
Configuration with PC 19
Configuration with telephone 20
Remote configuration with telephone 21
On-site configuration with telephone 23
Configuration examples 24
Parameter list 25
Relay functions 32
CONFIGURATION
START UP
Overview SL6+ main unit 6
Overview SL6+ bus unit 7
Other components 9
Mounting 10
Wiring diagram SL6+ main unit 11
Wiring diagram, bus unit 12
Wiring diagram, bus unit screw terminals 13
Connecting the telephone line 13
Activating the SIM card 14
INSTALLATION
OVERVIEW
General information 4
Declaration of conformity 4
Safety precautions 4
INTRODUCTION
Table of contents
Description of the bus system 5
System overview 5
LED indication front panel 15
LED indication for pictograms in car 16
Startup procedure 17
CERTIFICATE

4
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SL6+ v2.04 EN
Introduction
GENERAL INFORMATION
This unit was built to state-of-the-art technology
and to generally recognised safety related
technical standards currently applicable. These
installation instructions are to be followed by all
people working with the unit, in both installation
and maintenance.
It is extremely important that these installation
instructions are made available at all times to the
relevant technicians, engineers or servicing and
maintenance personnel. The basis prerequisite
for safe handling and trouble free operation of
this system is a sound knowledge of the basic and
special safety regulations concerning conveyor
technology, and elevators in particular.
The unit may only be used for its intended
purpose. Note in particular that, no unauthorised
changes or additions may be made inside the
unit or individual components.
Exclusion of liability
The manufacturer is not liable with respect
to the buyer of this product or to third parties
for damage, loss, costs or work incurred as
a result of accidents, misuse of the product,
incorrect installation or illegal changes, repairs
or additions. Claims under warranty are likewise
excluded in such cases. The technical data is the
latest available. The manufacturer accepts no
liability arising from printing errors, mistakes or
changes.
DECLARATION OF CONFORMITY
Download ”The declaration of conformity” at our
website: www.safeline-group.com
SAFETY PRECAUTIONS!
• Only trained professionals, who are authorised
to work on the equipment, should install and
configure this product.
• This quality product is dedicated for the
lift industry. It has been designed and
manufactured to be used for its specified
purpose only. If it is to be used for any other
purpose SafeLine must be contacted in
advance.
• It should not be modified or altered in any way,
and should only be installed and configured
strictly following the procedures described in
this manual.
• All applicable health and safety requirements
and equipment standards should be
considered and strictly adhered to when
installing and configuring this product.
• After installation and configuration this
product and the operation of the equipment
should be fully tested to ensure correct
operation before the equipment is returned to
normal use.
Electrical and electronic products may contain
materials, parts and units that can be dangerous
for the environment and human health. Products
marked with the WEEE mark (shown below),
shall not be disposed together with your normal
household waste. Please inform yourself about
the local rules and disposal collection system for
electrical and electronic products. The correct
disposal of your old product will help to prevent
negative consequences for the environment and
human health.
(WEEE = Waste of Electrical & Electronic
Equipment).

5
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
0
1
23
4
5
6
7
8
9
0
1
23
4
5
6
7
8
9
0
1
23
4
5
6
7
8
9
0
1
23
4
5
6
7
8
9
0
1
23
4
5
6
7
8
9
0
1
23
4
5
6
7
8
9
SafeLine Pro
SafeLine
Pro
SL6+ v2.04 EN
Overview
SYSTEM OVERVIEW
• TheSL6+usesabus systemforcommunication
between the main unit and the bus units.
• The bus consists of four wires, which transfers
power, voice and data.
• You can have one SL6+ main unit and up to
six bus units connected to the same bus.
• The system uses addresses to communicate
with a selected bus unit. It is important that
each unit have the address selector set to an
unique address. Available addresses are 1 to 6.
Intercom and
configuration handset
Configfuration and
Software update
BUS
GSM LED
PSTN
USB RS232
System
Speaker
Aux. input 1
Aux. input 2
Emg. bell
Emg.
button SW
update
External
pictogram Internal
Emg. light
SW
update SW
update SW
update SW
update
Emg./Push
to talk
button
Emg./Push
to talk
button
Push
to talk
button
Push
to talk
button
Push
to talk
button
Emg. light
Address
selector Address
selector
Address
selector
Address
selector
Address
selector Address
selector
CAR UNIT CAR TOP LIFT PIT FIRE UNIT FIRE UNIT FIRE UNIT
SW
update
DESCRIPTION OF THE BUS SYSTEM

6© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
44553
1000
6E
44553
1000
6E
23a3b 3c 4
12
6
8
1 5
10
7
9
13
11
SL6+ v2.04 EN
Installation
OVERVIEW SL6+ MAIN UNIT
1. Connector RJ12 for optional telephone
handset
For configuration and intercom communication.
Can also be used for external calls.
Any standard analogue tone dial telephone can
be used.
2. Reset button
• Reset all alarms.
• Terminates a phone call in progress.
• Triggers self test.
• Activates display of GSM signal strength.
• Triggers battery test.
3. LED indicators
a. Mains power
b. Active alarm/battery status
c. PSTN/GSM Net, call status
4. USB Mini B PC connection
For firmware update and configuration.
5. RS232 PC connection
For configuration.
6.
Screw terminal for optional telephone
handset
For configuration and intercom communication.
Can also be used for external calls.
Any standard analogue tone dial telephone can
be used.
7. Slot for optional card (not yet implementet)
8. Connector for external system speaker
9. GND
10. Terminals
11. 12 V Battery, 1,2 Ah
12. Slot for GSM interface board
13. Batteryslot for RTC, Real Time Clock
(not yet implementet)

7
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
ADDRESS
J2
LOCAL BUTTON
BUS A
BUS B
OUT A (YELL.)
OUT B (GREEN)
INPUT A
INPUT B
EMG LIGHT +
HEARING LOOP
BUS GND
BUS 12V
J4 J3
-
RS2
5 7
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
BUS-STATION
WWW.SAFELINE.SE
K1
K2
K3
K4
K5
K6
K7
K8
K9
K10
P6
P4
P5
P2
P3
P7
6
9 10 11
21 3 4
8
!
SL6+ v2.04 EN
Installation
Default address setting
Address Unit
1 Car unit
2 Top unit
3 Lift pit unit
4 Fire unit
5 Fire unit
6 Fire unit
* Note: This connection may not be present.
It depends on the nature of your product.
OVERVIEW SL6+ BUS UNIT
1. Local button*
Only N/O.
Is connected with *Cable13.
2. Screw connector terminals*
3. Emergency light*
Is connected with *Cable13.
4. Hearing loop*
Is connected with *Cable13.
5. RS232 PC connection
For firmware update.
6. Terminal RJ45
Input/Output, bus connection, power
and external pictogram.
7. Address selector
Selects the bus address for the unit.
8. Volume control
9. Pictogram Yellow
10. Microphone
11. Pictogram Green
If the unit type for a selected address
needs to be changed, it is done in the
SafeLine Pro settingts for the main unit
(on the bus units’ button).

8© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
1
6
ADDRESS: 1
VOLUME
sw version
serial number
5432
98
SL6+ v2.04 EN
Installation
OVERVIEW SL6+ BUS UNIT
1. Address selector
Fixed value set to 1 (car unit).
2. Connections
3. Pictogram output
4. Additional Alarm Button, only N/O
5. RS232 PC connection
6. Volume control
7. Emergency Light, only for SLB-SM-Pic-Light
8. Hearing loop

9
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
3
4
5
1 2
43254
100
35V
43254
100
35V
63432
1000
6F
63432
1000
6F
SIM Card
73274
1000
6F
73274
1000
6F
100
35V
100
35V
TP5 TP11 TP9 TP3 TP12
TP7 TP4 TP6 TP8 TP10 TP1
SIM Card
SL6+ v2.04 EN
Installation
1. GSM antenna connector, SMA
Circuit boards to use:
*SL6-GSM-BOARD or *IF-BOARD-4G (see
technical data, page 2, for detailed information).
2. SafeLine bus station for lift pit/car top
Mounted in the lift shaft, on top or under the car.
3. GSM antenna
4. SafeLine bus station for car
Equipped with a speaker and a microphone. Bus
units available with pictograms to comply with
EN 81-28. Also available with emergency alarm
button and Rec Fire Key (keyswitch for fire
intercom.)
5. SafeLine bus station with emergency light,
for car
Equipped with a speaker, a microphone and a
built in emergency light in the frame. Bus units
available with pictograms to comply with EN 81-28.
OTHER COMPONENTS

10 © 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SafeLine SL6
>> 1,5 m>> 1,5 m
>> 1,5 m
44553
1000
6E
44553
1000
6E
73274
1000
6F
73274
1000
6F
100
35V
100
35V
TP5 TP11 TP9 TP3 TP12
TP7 TP4 TP6 TP8 TP10 TP1
SIM Card
43254
100
35V
43254
100
35V
63432
1000
6F
63432
1000
6F
SIM Card
Micro
SIM Card
Micro
SIM Card
SL6+ v2.04 EN
Installation
Install the main unit in the machine room.
No termination resistance is needed at the ends
of the bus.
To avoid GSM interference: Place the main
unit, the stations and the GSM antenna at least
1,5 meters apart.
MOUNTING
Mounting circuit board
Unplug the main power and battery before
performing any changes.
Mounting circuit board
*SL6-GSM-BOARD
(see technical data, page 2,
for detailed information).
Mounting circuit board
*IF-BOARD-4G
(see technical data, page 2,
for detailed information).
If GSM interface is installed it has priority.
If no active SIM-card is used, GSM interface
should be disabled.

11
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
1
2
1
2
3
4
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
1
2
A
B
C
D
E
F
SL6+ v2.04 EN
Installation
PHONE LINE, RJ12
RELAY 1 COMMON
RELAY 1 N/C
RELAY 1 N/O
PHONE LINE
PHONE LINE
BUS 12 VDC
BUS GND
BUS A
BUS B
BATTERY +12 VDC
BATTERY 0 VDC
+12 VDC
**INPUT 2 (configurable)
**INPUT 1 (configurable)
*EMERGENCY BELL +
*EMERGENCY BELL –
EMERGENCY LIGHT +
230 VAC L
230 VAC N
EMERGENCY LIGHT –
Input 1 and 2 Options
NONE
FILTER
LMS/SMS
CLEAR/MAINTENANCE
FIRE MODE (default input 2)
ALARM BUTTON (default input 1)
CALL DELAY
* Maximum 200 mA on the
Emergency bell output.
** Input 1 and 2 are
configurable N/O or N/C inputs
with SafeLine Pro as indicated
below. RELAY 2 COMMON
RELAY 2 N/C
RELAY 2 N/O
WIRING DIAGRAM SL6+ MAIN UNIT

12 © 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
ADDRESS: 1
44553
1000
6E
44553
44553
1000
1000
6E
6E
44553
1000
6E
44553
1000
6E
B
SL6+ v2.04 EN
Installation
*Input A is configurable with either:
• SafeLine Pro N/O (default) or N/C.
• Parameter *89*, please refer to the corresponding code in the ”Parameter list”.
WIRING DIAGRAM, BUS UNIT
GREY
ORANGE
BLACK
RED
YELLOW
GREEN
BLUE
BROWN
INPUT B NOT IN USE
INPUT A ALARM BUTTON (OPTIONAL)
OUTPUT A, YELLOW PICT. (OPTIONAL)
OUTPUT B, GREEN PICT. (OPTIONAL)
B2 BUS GND
B1 BUS POWER
B4 BUS B
B3 BUS A
ONLY WHEN USING
EXTERNAL PICTOGRAM AND ALARM BUTTON
JST connection
RJ45 connection

13
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
44553
1000
44553
1000
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
COPYRIGHT SAFELINE AB 2011
WWW.SAFELINE.SE
SL6 R1.12
SPEAKER
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
COPYRIGHT SAFELINE AB 2011
WWW.SAFELINE.SE
SL6 R1.12
SPEAKER
44553
1000
44553
1000
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
COPYRIGHT SAFELINE AB 2011
WWW.SAFELINE.SE
SL6 R1.12
SPEAKER
44553
1000
6E
A A A
RJ12
8
7
6
5
4
3
2
1
SL6+ v2.04 EN
Installation
CONNECTING THE TELEPHONE LINE
Connect the telephone line in parallell in universal
terminals or the RJ-plug, see the picture above.
It’s possible to connect up to nine SL6+ main
units to the same telephone line.
In order to access the unit remotely, it needs to
be assigned a unit number.
Please refere to parameter *82* in the
“Parameter list” for more information.
Phone line is connected via RJ12 through the
following diagram:
7. BUS GND
8. BUS 12 VDC
6. NOT IN USE
5. INPUT A*, ALARM BUTTON
4. OUTPUT B, GREEN PICTOGRAM
3. OUTPUT A, YELLOW PICTOGRAM
1. BUS A
2. BUS B
*Input A is configurable with either:
• SafeLine Pro N/O (default) or N/C.
• Parameter *89*, please refer to the
corresponding code in the ”Parameter list”.
1
2
3
4
5
6
Input
Not in use
Output
Output
Not in use
Input
WIRING DIAGRAM
BUS UNIT SCREW TERMINALS

14 © 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SL6+ v2.04 EN
Installation
The SL6+ can only recognise the PIN code if
the code is set to “1234”, “0000”, “1111” or is
deactivated. If the PIN code is set to “1234”,
“0000” or if it is deactivated, the SIM card can
be moved from the SL6+ to any of SafeLine GSM
products.
TIP: Do not activate the voice mail or if possible
ask your provider to deactivate the voice mail.
If the PIN code is set to “1111” the SIM card code
will be randomly changed by the SafeLine GSM
unit and memorized. This way the SIM card can
only work with the SafeLine GSM unit unless you
use the PUK code for setting up a new PIN code.
If you want to upload a new SIM card with PIN
code “1111” you will first need to upload a SIM card
with PIN code “1234” or “0000” to clear the old
code in memory.
Setting the PIN code
(Set to “1234”, “0000” or deactivate.)
1. Insert the SIM card in an ordinary cellular
phone. In the “Security settings” menu,
change the PIN code to “1234”. If this is not
possible, set the PIN code to “0000” or set
the ”PIN code request” option to “OFF”
(might not always function).
2. Verify the PIN code by switching your phone
off and on again.
3. Make a call from your phone to verify that the
SIM card is active before you move it to the
SL6+.
4. Also make a call to SL6+ after insertion
to check that it is possible to get a proper
connection.
If you enter the wrong PIN code 3 times, the
SIM card will be blocked (requires PUK code
to unblock). The SL6+ can not be started and
the LED3 will turn red.
ACTIVATING THE SIM CARD

15
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
6E
44553
1000
COPYRIGHT SAFELINE AB 2011
WWW.SAFELINE.SE
SL6 R1.12
SPEAKER
SPEAKER
SPEAKER
SL6+ v2.04 EN
Start up
LED 1
LED 2
LED 3
Reset
LED INDICATION FRONT PANEL
LED 1 indicates the power supply status
Continuous Green Mains power supply OK.
Flashing Red (400/400 ms) Battery operated, with power to the emergency light.
Continuous Red Battery operated, no power to the emergency light.
LED 2 indicates active alarm and battery condition
Light Off No active alarm/battery OK.
Rapidly Flashing Yellow (200/200 ms)
Active alarm not reset.
Flashing Red (400/400 ms) Battery check in progress.
Continuous Red Battery test failure/no battery connected.
LED 3 indicates the phone line’s status
Flashing Green (100/100 ms) Fire Mode activated.
Flashing Green (400/400 ms) Call connection in progress.
Slowly Flashing Green (200/4600 ms)
Telephone line connected.
GSM network OK.
Continuous Green Call connected.
Flashing Yellow (100/100 ms) Incoming call.
Flashing Red (400/400 ms) No telephone line connected.
Searching for GSM network.
Continuous Red No SIM card (when using GSM).
Reset button
Press for 3 sec Show GSM signal strength (see table above).
Press 3 times Start a self test (battery + bus initialization).
Press Once Resets an active alarm. Aborts calls in progress.
Press 5 sec - Release SL6+ turns off. NOTE! Refers to battery powered only!
COLOUR CODE LED
1 2 3
GSM SIGNAL
STRENGTH
3 green = 100 %
1 yellow, 2 green = 85 %
2 yellow, 1 green = 70 %
3 yellow = 55 %
1 red, 2 yellow* = 30 %
2 red, 1 yellow = 15 %
3 red = 0 %
*Minimum signal strength for using GSM Interface.

16
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SL6+ v2.04 EN
Start up
Yellow LED, “Call in progress“
The yellow pictogram LED, is lit as soon as the
alarm button is pressed.
Green LED, “Call connected“
The green pictogram LED turns on as soon as
the SafeLine unit detects a responding voice.
The LED is turned off when the call is terminated.
LED INDICATION FOR PICTOGRAMS IN CAR
STANDARD (*78*0#), YELLOW LED
Light Off
No alarm activated.
Flashing Once every 5 seconds
Telephone line not OK.
Flashing Twice every second
Emergency alarm button active.
Continuous Yellow Light
Activated alarm. Remains lit until reset.
STRICTLY EN81-28 (*78*1#), YELLOW LED
Flashing Twice every second
Emergency alarm button active.
Continuous Yellow Light
Activated alarm. Remains lit until reset.
STANDARD (*78*0#), GREEN LED
Light Off
Telephone line not OK.
Flashing Once every 5 seconds
Unit is OK.
Flashing Two times every 5 seconds
Alarm filter activated.
Continuous Green Light
Call connected.
STRICTLY EN81-28 (*78*1#), GREEN LED
Continuous Green Light
Call connected.

17
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
1
2
4
6
3
5
7
1
2
3
4
5
6
7
123456
SL6+ v2.04 EN
Start up
Connect 230 VAC.
LED 1
turns green?
Number of beeps
OK?
LED 3 flashing
OK?
Unit communication
failure.
Connect the battery.
Start up procedure
ready.
No
Yes
Start up the SL6+.
SL6+ checks for valid
telephone line or GSM net.
SL6+ searches for
connected bus units.
No telephone line
or GSM net.
No 230 VAC
or broken unit.
Yes
Yes
No
No
The unit will not start at
battery connection only.
A tone sequence is heard
in the system speaker at
start up.
Check 230 VAC mains
power.
SL6+ main unit searches
for units connected to
the bus. For every bus
unit found, a beep sound
is heard in the system
speaker in the SL6+ main
unit.
Refer to chapter - Trouble
shooting bus unit.
When a valid telephone
line is connected, or a
GSM net is available LED3
is flashing green every 5
seconds.
Refer to chapter - Trouble
shooting Main unit.
Example: Found all bus
units except for number 3.
STARTUP PROCEDURE

18 © 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SL6+ v2.04 EN
Configuration
App Store, iPhone Google play, Android
CONNECT is the new tool from SafeLine that will
make configuring SafeLine products even easier
than before.
Configuration is done wirelessly with compatible
products and the SafeLine CONNECT smartphone
app (available free of charge on the Apple App
Store and on Google Play). The app has an
easy to use interface for the configuration and
settings of the SafeLine product.
Easy to learn and use
Thanks to the well designed user interface,
CONNECT is very intuitive to use, with quick
and easy configuration of SafeLine products.
Simply follow the steps in the app to configure
the SafeLine unit. There is no longer any need
to use a computer or to remember a wide list
of configuration codes in order to configure
SafeLine products. CONNECT functions includes
templates which will allow pre-configured
settings.
CONNECT secure
CONNECT is protected against unauthorised use,
and all SafeLine products with built-in CONNECT
functionality, are password protected.
Always accessible
With the built-in CONNECT functionality in the
SafeLine products, the product configuration
is always accessible, all that is needed is a
smartphone (or tablet) with the free app
installed. No computer will be needed to make
any configuration or settings changes.
CONNECT
If the unit has been idle for more then
10 minutes when trying to connect, it will
ask for a password.
If that is the case, please turn the unit off
and on again, and then try to reconnect.

19
© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SafeLine Pro
SafeLine
Pro
SafeLine SL6
SafeLine SL6
SafeLine
ProLink
SafeLine Pro
SafeLine
Pro
SL6+ v2.04 EN
Configuration
Configuration with SafeLine Pro.
The unit can be configured at the office prior
to the installation or on site after installation.
The configuration software SafeLine Pro can be
downloaded from www.safeline-group.com.
The configuration cable is provided by SafeLine.
If SafeLine Pro is used for configuration, you can
go directly to chapter “Operating”.
CONFIGURATION WITH PC
Remote confi guration with SafeLine Pro.
The unit can also be remotely confi gured at the
offi ce after installation.
Connect a SafeLine ProLink modem with a phone
line to a computer with SafeLine Pro and a serial
cable.

20 © 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.
SafeLine SL6
SafeLine SL6
SL6+ v2.04 EN
Configuration
CONFIGURATION WITH TELEPHONE
On site configuration with telephone
For configuration, you can use any PSTN tone dial
phone.
• Plug the handset into the RJ12-contact of the
main station.
• Enter configuration codes on the handset
keypad.
Remote configuration with telephone
For remote configuration, you can use any PSTN
tone dial phone.
• Dial the phone number of the SL6+.
• Enter the function codes on the phone keypad
to start configuration (password has to be
entered).
Configuration methods with telephone and
configuration codes are described in “Remote
configuration with telephone...”.
Other manuals for SL6+
3
Table of contents