Pulnix TM-6703 User manual

TM-6703
Progressive Scan Double Speed Shutter Camera
Operation Manual
69-0061
Rev. A

Notice
The material contained in this manual consists of information that is proprietary to PULNiX America, Inc., and may only
be used by the purchasers of the product. PULNiX America, Inc. makes no warranty for the use of its product and assumes
no responsibility for any errors which may appear or for damages resulting from the use of the information contained
herein. PULNiX America, Inc. reserves the right to make changes without notice.
Warranty
All of our solid state cameras have a full three-year warranty. If any such product proves defective during this warranty
period, PULNiX America, Inc. will repair the defective product without charge for parts and labor or will provide a
replacement in exchange for the defective product. This warranty shall not apply to any damage, defect or failure caused
by improper use or inadequate maintenance and use.
Certifications
CE Compliance
The TM-6703 has been certified to conform to the requirements of Council Directive 89/336/EC for electromagnetic
compatibility and to comply with the following European Standards:
Immunity: EN500082-2/1995
Emissions: EN55022:1995 Class A / CISPR 22:1993
All PULNiX products bearing the CE mark have been declared to be in conformance with the applicable EEC Council
Directives. However, certain factory installed options or customer requested modifications may compromise
electromagnetic compatibility and prohibit use of the CE mark. Please note that the use of interconnect cables that are not
properly grounded and shielded may affect CE compliance.
Contact the PULNiX Applications Engineering Department for further information regarding CE compliance.
FCC
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
W
ARNING
Changes or modifications to this unit not expressly approved by the party responsible
for FCC compliance could void the user’s authority to operate the equipment.
TM-6703 Operation Manual
Printing:April 26, 1999
PULNiX America, Inc.
1330 Orleans Drive
Sunnyvale, CA 94089
Tel: (408) 747-0300
Tel: (800) 445-5444
Fax: (408) 747-0880
E-mail: imaging@jaipulnix.com
www.pulnix.com

Table of Contents
i
1 INTRODUCTION .................................................................... 1
1.1 Product Description .......................................................................... 1
1.2 Features ........................................................................................... 1
1.3 Functional Options ........................................................................... 3
2 INSTALLATION ..................................................................... 4
2.1 Getting Started ................................................................................. 4
2.1.1 Unpacking Instructions ........................................................ 4
2.1.2 Components List ................................................................. 4
2.1.3 Accessories ......................................................................... 4
2.2 Camera Setup .................................................................................. 5
2.2.1 Connector Pin Configurations ............................................. 5
2.2.2 Rear Panel .......................................................................... 5
2.2.3 Power Supply and Power Cable Setup ................................ 5
2.2.4 Attaching the Video Output ................................................. 7
2.2.5 Attaching the Camera Lens ................................................. 7
2.2.6 Back Focusing the Lens ...................................................... 7
2.2.7 Auto Iris Lens Setup ............................................................ 8
2.2.8 Non-Interlace Black & White Monitors ................................. 8
3 OPERATION .......................................................................... 9
3.1 Modes of Operation .......................................................................... 9
3.1.1 Asynchronous Reset Mode ................................................. 9
3.1.2 Driving /VINIT ...................................................................... 10
3.1.3 Shutter Control Switch ........................................................ 11
3.1.4 Progressive Scanning ......................................................... 14
3.1.5 Option 7-2 ........................................................................... 15
3.1.6 V-Sync Output Selection for Async Mode (OP51-2) ............ 15
3.1.7 Integration ........................................................................... 16
3.1.8 External Input Signals ......................................................... 16
3.2 Board Layout and Adjustment .......................................................... 17
3.2.1 Top Board (Top Side) .......................................................... 17
3.2.2 Bottom Board (Bottom Side) ............................................... 17
4 TROUBLESHOOTING ........................................................... 18
4.1 Problems and Solutions ................................................................... 18
4.1.1 Symptom: No Video ............................................................. 18
4.1.2 Symptom: Dark Video .......................................................... 18
4.1.3 Symptom: Non-synchronized Video .................................... 18
4.2 Information and Support Resources ................................................ 19

Table of Contents
ii
5 APPENDIX .............................................................................20
5.1 Specifications ...................................................................................20
5.1.1 Product Specifications .........................................................20
5.1.2 Physical Dimensions ............................................................ 21
5.1.3 Glass Specifications ............................................................ 22
5.1.4 C-Mount Specifications ........................................................ 22
5.1.5 Front End Detail ...................................................................23
5.2 Spectral Response ...........................................................................24
5.3 Block Diagram ..................................................................................24
5.4 Timing Chart .....................................................................................25
5.4.1 Pixel Mapping (Horizontal) ................................................... 25
5.4.2 Vertical Frame Output Timing ..............................................25

List of Figures
iii
FIGURE 1. TM-6703 System Configuration .................................................3
FIGURE 2. 12P-02 Interface Cable (optional) ..............................................6
FIGURE 3. Asynchronous Reset ..................................................................9
FIGURE 4. VINIT (Vertical Initialization) Trigger Specifications ....................10
FIGURE 5. Equivalent Circuit .......................................................................10
FIGURE 6. External Pulse Width Control (Async Mode) ..............................12
FIGURE 7. Internal Fast Reset .....................................................................12
FIGURE 8. Internal Slow Reset ....................................................................13
FIGURE 9. Scan Output ...............................................................................15
FIGURE 10. I/O Jumpers ................................................................................15
FIGURE 11. Integration Timing ....................................................................... 16
FIGURE 12. Internal Input Signals .................................................................16
FIGURE 13. Physical Dimensions ..................................................................21
FIGURE 14. Camera Front End - Glass Specifications .................................. 22
FIGURE 15. Combination With “CS-Mount” Camera ......................................23
FIGURE 16. TM-6703 Imager Location ..........................................................23
FIGURE 17. Spectral Response .....................................................................24
FIGURE 18. TM-6703 Block Diagram ............................................................. 24
FIGURE 19. Pixel Mapping (Horizontal) .........................................................25
FIGURE 20. Vertical Frame Output Timing .....................................................25

April 22, 1999
Page 1
TM-6703 Progressive Scan
Double Speed Shutter Camera
Operation Manual
1 INTRODUCTION
1.1 Product Description
The TM-6703 is a high resolution monochrome camera with three scanning modes: Non-interlace
double speed scanning VGA format (60Hz); two-row scanning (120Hz); and partial scanning (100 and
200 lines). Features include compact size, rugged construction, double speed scan, asynchronous reset
and electronic shutter, non-interlace 60Hz analog video (VGA), and partial scanning. The double speed
mode is standard, thus the images can be displayed on a standard VGA monitor.
Applications include high speed image capturing, machine vision, computer graphics, gauging,
avionics, microscopy, character and fine pattern recognition, document reading and high end
surveillance.
1.2 Features
•
1/2" progressive scan interline transfer CCD
Advantages include:
-
648H x 484V active pixels for very high resolution and superior image quality
-
Square pixels (9.0 x 9.0
µ
m) for precise dimensional measurements
-
Double speed scanning
-
Partial scan capability allows 120Hz two-row scanning (combining two lines), 100 and 200 lines
of partial scan as well as 60Hz frame scanning. All images are centered in the video frame
-
High speed electronic shutter capability results in high dynamic resolution of moving objects
-
Progressive scanning eliminates interlace image deterioration
-
High sensitivity and low noise at fast scanning, excellent S/N ratio (>50db)

INTRODUCTION
Page 2 TM-6703 Progressive Scan Double Speed Shutter Camera
•
Asynchronous reset
The TM-6703 resets with an external reset pulse (VINIT). This feature is especially important for
capturing moving objects at a precise location in the field of view, for applications such as a
conveyer belt process, fast event observation, and still picture capturing.
•
Integration
The TM-6703 is capable of capturing high resolution integration images. Integration can last from
1/60 sec. to several seconds.
•
VGA display output
The TM-6703’s VGA output scans out at 60Hz non-interlace. Because the double speed mode is
standard, images can be displayed on a standard VGA monitor. PULNiX PVM-1200 series
monitors or equivalent B/W multi-sync monitors can be used to display non-interlace images.
Please contact your PULNiX representative for display monitor information.
•
Sync input (external sync) or output (clock and sync) selection (optional, OP7-2))
Rear board jumpers enable sync input/output selection. When the jumpers are set to internal sync,
the camera accepts HD and VD sync and video output from pin #4 of the 12-pin connector. If the
jumpers are set to OP7-2, then HD, VD and clock output are provided for a frame grabber to take
the data.
•
“One shot sync” (optional, OP51-2)
The composite sync of the video output can be selectable with the rear panel jumper (resistor
location). Continuous V-sync mode outputs the V-sync at all times regardless of async reset or
normal rate V-sync during async mode stand-by. Async V-sync mode outputs the V-sync once only
at async reset (at Vinit trigger) and no V-sync during the stand-by period (H-sync only in video
composite sync) until the next Vinit comes in. These modes can be selected based on a frame
grabber’s sync capability for async reset.
•
Three-Year Warranty
The CCD solid state image sensor allows the camera to maintain a superior performance level
indefinitely while requiring virtually no maintenance. PULNiX backs all of the TM Series cameras
with a three-year warranty.
WARNING: Unscrewing the camera cover or opening the camera in any way
will void this warranty.

INTRODUCTION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 3
1.3 Functional Options
•
Optical Filter Removal (OP3-2)
•
Glassless CCD Imager (OP21)
•
Internal IR Filter (OP3-1)
•
Pixel Clock, HD, and VD output (OP7-2)
•
One Shot Sync (OP51-2)
•
Remote Head (OP10-1)
FIGURE 1.
TM-6703 System Configuration
Note:
Additional cable interface may be required from the frame grabber board manufacturer.
GAIN
N
VIDEO
SHUTTER
POWER
P
ASY
MAN
O
T
012
3
4
5
6
7
8
9
PULNiX Multi-Sync
Monitor
(PVM-1242 or PVM-942)
Power
External Sync
Integration
Video Output*
Computer with
Frame Grabber
Board
(if required)
* Video Output is the
same as BNC connector

INSTALLATION
Page 4 TM-6703 Progressive Scan Double Speed Shutter Camera
2 INSTALLATION
The following instructions are provided to help you to set up your video camera system quickly and
easily. It is suggested that you read through these instructions prior to unpacking and setting up your
camera system.
2.1 Getting Started
2.1.1 Unpacking Instructions
It is recommended that the original packing cartons for the cameras and lenses be saved in case there is
a need to return or exchange an item.
It is also recommended that any equipment being sent to another location for field installation be bench
tested to assure that everything is fully operational as a system.
2.1.2 Components List
Please begin by checking your order against the Components List (below) to assure that you have
received everything as ordered, and that nothing has been overlooked in the packing materials. If any
item is missing, please contact your PULNiX representative immediately.
•
TM-6703 camera
•
TM-6703 data sheet
•
TM-6703 manual (by request)
2.1.3 Accessories
Following is a list of additional accessories or equipment that may be recommended or required for your
particular application. Please check with your PULNiX representative prior to the installation of your
video system to determine what you might need.
•
Cable (power/video) 12P-02
•
PVM-1242 or PVM-942 multi sync monitor
•
Power supply PD-12P

INSTALLATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 5
2.2 Camera Setup
2.2.1 Connector Pin Configurations
2.2.1 (a) 12-Pin Connector
The TM-6703 has a 12-pin connector for power input.
2.2.2 Rear Panel
Functions and controls located on the camera rear panel:
•
12-pin connector (power, I/Os)
•
BNC video cable connector
•
Shutter speed selection dial
•
ASY/MAN switch (asynchronous shutter and manual shutter switch)
•
N/P and O/T switches (scanning mode selection)
•
Manual gain control adjustment
2.2.3 Power Supply and Power Cable Setup
2.2.3 (a) Power Supplies
PULNiX recommends the following power supplies:
K25-12 110V AC/12V DC 2.1A power supply
P-15-12 220V AC/12V DC 2.1A power supply
K50-12 110V AC/12V DC 4.2A power supply
PD-12P 110V AC/12V DC 0.5A power supply
For users providing power through the 12-pin connector, the PD-12P power supply is available with the
12-pin mating connector already attached to the leads from the power supply. The PD-12 power supply
can be connected to the PULNiX power cable via a terminal strip or directly.
Pin# Description Pin# Description
1 GND 7 V
D
in (out OP7-2)
2 +12V DC 8 GND
3 GND 9 H
D
in (out OP7-2)
4 Video Out (clk out OP7-2) 10 N/C
5 GND 11 Integration
6 VINIT In 12 GND
1
2
3
456
9
8
7
11 12
10
GAIN
N
VIDEO
SHUTTER
POWER
P
ASY
MAN
O
T
012
3
4
5
6
7
8
9
PULNiX
Rear Panel

INSTALLATION
Page 6 TM-6703 Progressive Scan Double Speed Shutter Camera
If wiring the PD-12 power supply directly, please note the following
•Twist the lead ends together and tin solder for strength and electrical continuity
•Use shrink tubing or a similar insulator to prevent exposed leads from touching
•The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads
•Properly insulate all connections to prevent shorting
2.2.3 (b) Using PULNiX Power/Video Cables
If you are using PULNiX power cables, such as the 12P-02, KC-10, etc., please refer to the pin-out
diagram. The color coded leads use Grey for Ground and Yellow for +12V DC.
FIGURE 2. 12P-02 Interface Cable (optional)
Note: Make sure that the unused leads are not touching and that there is no possibility that the
leads could short due to exposed wires.
2.2.3 (c) Using the “K”Series Power Supplies
Attach the 110V line cord to the two terminals marked “AC”. Do not plug the cord into a 110V AC
socket until later in the procedure. Next, attach the Grey and Yellow leads of the power cable to the
Ground and 12V DC terminals respectively. Be sure to replace the plastic terminal guard on the power
supply at this time.
12P-02 Interface Cable
Pin# Lead Color Function Pin# Lead Color Function
1 Gray GND 7 Black coax VD Input
2 Yellow +12VCD 8 White coax shield GND
3 Red coax shield GND 9 White coax HD Input
4 Red coax Video 10 Brown N/C
5 Orange coax shield GND 11 Blue Integration
6 Orange coax N/C 12 Black coax shield N/C
132mm
2,000mm±10mm
(2 Meters)
PC-12P (Hirose Part #10A-10P-12S/PC12P)
Flying
Leads
1

INSTALLATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 7
Note: The “K” series power supplies are designed primarily for OEM users who will be
mounting the power supply inside a protective enclosure. For use in exposed situations,
the DC-12N and PD-12 are recommended.
2.2.3 (d) Building Your Own Power Cables
If you are building your own power cables, consult the pin-out for the camera purchased and connect the
Ground and +12V power leads of the PC-12P power connector to Pin #1 and Pin #2, respectively
(power must be DC regulated, and of sufficient current to properly power the camera).
2.2.3 (e) Attaching the Power Cable to the Connector
The 12-pin connector is keyed and will only fit in one orientation. Rotate the connector while applying
slight pressure until the keyways line up. Press the connector into place until firmly seated.
The power cord may now be plugged into the 100V AC socket, and the camera powered up.
2.2.4 Attaching the Video Output
Most users utilize the BNC connector for video output from the camera. Connect the output from the
camera to the input of your monitor, VCR or switching device. The input of the monitor should be
balanced for 75Ωtermination. Standard RG-59 type coaxial cable should carry a full video signal for up
to 500 feet.
Users wishing to output the video and input the power and sync to a camera over a single cable can use
the PULNiX multi-conductor cables, such as the 12P-02, the KC-10, etc. The mini coaxial leads in
PULNiX multi-conductor cables are designed for short runs of no longer than 100 feet.
Note: Make sure that no extraneous wires are visible which could cause a short.
2.2.5 Attaching the Camera Lens
The TM-6703 camera accepts standard C-mount lenses. To attach the C-mount lens to the camera,
carefully engage the threads and rotate the lens clockwise until it firmly seats on the mounting ring. Do
not force the lens if it does not seat properly. Please note that some lenses with extremely long
flangebacks may exceed the mounting depth of the camera.
2.2.6 Back Focusing the Lens
To backfocus the TM-6703 camera, first attach a C-mount lens in the lens mount. Be sure that the lens is
properly mounted.
Set the lens focus to infinity (if the lens is a manual iris, set the iris to a high f-stop while still retaining a
well-illuminated image). Obtain the best focus possible at this setting, then loosen the two miniature hex
head set screws (hex socket size: 0.89mm) locking the focus ring in place. Now turn the entire lens and
focus ring assembly back and forth until the best image is obtained. Tighten the focus ring set screws.
Your backfocus is now set.

INSTALLATION
Page 8 TM-6703 Progressive Scan Double Speed Shutter Camera
2.2.7 Auto Iris Lens Setup
Auto-iris lenses with full video input (1 Vpp) can be used with the PULNiX TM-6703, although this
camera model does not come equipped with auto-iris output.
Note: Make sure that the power is removed from the camera before connecting or disconnecting
the auto-iris lens. There is a small chance that damage could occur to the auto-iris lens by
plugging or unplugging it while the camera is powered up.
To install the auto-iris lens in a PULNiX camera for which the auto-iris output is not supplied, wire the
signal (video) on the lens into the terminal 1 Vp to peak video output on the camera (pin 4 of 12 pin
connector).
Point the camera at a light area and then quickly towards a darker area. If everything is working
properly, the iris should adjust for the light change.
2.2.8 Non-Interlace Black & White Monitors
The PULNiX PVM-942 / 1242 non-interlace black and white monitor, or an equivalent model, can be
used to display the TM-6703’s various display modes. In standard operation, including RS-170
interlace, 60 Hz non-interlace, 30 Hz non-interlace and 120 Hz non-interlace (two-row scanning mode),
the display is normal. In the partial scanning mode, the vertical extends to fill the monitor screen and the
images will be distorted vertically.

OPERATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 9
3 OPERATION
3.1 Modes of Operation
The TM-6703 is designed to accommodate a high resolution, on-line inspection reset mechanism with
full frame shutter. It accepts external horizontal sync (HD, TTL Levels) to lock the camera and VINIT
pulse for resetting the camera asynchronously. The shutter speed can be controlled by either an external
double pulse, or by internal speed control by setting the 10-position shutter speed dial switch on the
back panel.
3.1.1 Asynchronous Reset Mode
For the asynchronous reset mode, select ASY on the back panel of the camera.
The TM-6703's asynchronous reset is flexible. External HD can be applied for phase locking if required.
Applying a VINIT pulse resets the camera's scanning and purging of the CCD. Do not supply VD if the
asynchronous reset is used. Instead, use HD to synchronize the camera to the external device.
When external VINIT is high (5V), the TM-6703 expects the async pulse input and the video output will
be black video. It resets at the negative going pulse edge and captures the frame regardless of the shutter
speed (fast or slow mode). The video output is kept disabled as the CCD is discharged continuously
during VINIT high. When the first VINIT pulse comes in, it resets the timing and outputs the image. If
the switch is set to NRM (normal mode), the video output will be real time with manual shutter.
FIGURE 3. Asynchronous Reset
EXTERNAL VINIT
INTERNAL VD
SG (TRANSFER GATE)
DISCHARGE PULSES
VIDEO
SHUTTER
VIDEO
NON-INTERLACE OUTPUT
ASYNC RESET

OPERATION
Page 10 TM-6703 Progressive Scan Double Speed Shutter Camera
3.1.2 Driving /VINIT
The TM-6703 VINIT input circuit equivalently has 10K ohm input resistance (Figure 4, “VINIT
(Vertical Initialization) Trigger Specifications,”on page 10). To drive this circuit, at least 0.5mA of
current is required to drive the camera.
Note: The VINIT signal must be a defined, clean pulse for the asynchronous reset function to
work properly. Some triggering systems (e.g., optical isolators, mechanical relays, noisy
electrical devices, etc.) have bounce or rapid transition between high and low states. It is
highly recommended that the input VINIT pulse be analyzed by test equipment to ensure
proper signal characteristics. If an unspecified signal is used, improper camera
performance may result.
FIGURE 4. VINIT (Vertical Initialization) Trigger Specifications
Note: PULNiX does not recommend voltage levels less than standard 0 to 5 V.
FIGURE 5. Equivalent Circuit
+5V
0 V
TTL
Level
t
t 2H 500H
Min. Max.
H = 31.8µs
10K
VINIT

OPERATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 11
3.1.3 Shutter Control Switch
The shutter control switch is located on the rear panel of the camera. The dial can be
set from 0 to 9. The settings are detailed below.
Mode 0: Normal Mode
Mode 1-4: Fast Mode
Mode 5-8: Slow Mode
Mode 9: Pulse Width Mode
Note: Manual shutter speeds lower than 1/1,000 (i.e., longer in duration) are not applicable for
partial scan due to the short frame rate.
3.1.3 (a) External Pulse Width Control Mode
To select the External Pulse Width Control mode, set the shutter speed dial switch to “9”. Apply a pulse
width control VINIT signal to the camera via an external event trigger. The internal reset pulse will be
latched to HD. At the 9th HDtiming from the external pulse leading edge (negative going edge), the
CCD discharge pulse will be generated to clear the images. The internal VDis generated at the
following edge (positive going edge) of the external pulse, and resets the internal timing, including the
video sync.
The shutter speed will be the same as the external pulse width, but the integration delays 9H from the
leading edge of the external pulse width. For the immediate reset option, please contact PULNiX.
One frame of video output will start from the rising edge of the pulse width control for progressive
format. The camera will output the same video from memory when VINIT is kept high (5V), and update
the image upon receiving the next pulse. At async mode, with external pulse input high, the video output
is disabled as the camera keeps discharging the CCD image and only will provide black video.
Position Manual Shutter Mode Async Reset Mode
0 No Shutter No Shutter
1 1/125 1.0H 1/32,000
2 1/250 2.0H 1/16,000
3 1/500 4.0H 1/8,000
4 1/1,000 8.0H 1/4,000
5 1/2,000 16.0H 1/2,000
6 1/4,000 32.0H 1/1,000
7 1/8,000 64.0H 1/500
8 1/16,000 128.0H 1/250
9 1/32,000 Shutter determined by pulse width
0
1
2
3
4
6
7
8
9
5

OPERATION
Page 12 TM-6703 Progressive Scan Double Speed Shutter Camera
FIGURE 6. External Pulse Width Control (Async Mode)
3.1.3 (b) Internal Fast Reset Mode (Async Mode)
For Internal Reset Mode, set the 10-position dial switch from “1”to “4”. When this mode is selected,
the camera resets with internal VDtiming, which is latched to Hd, and video output is also synchronized
with internal VDtiming without further delay. The shutter speed is controlled by the dial switch.
FIGURE 7. Internal Fast Reset
9H
X
External
Pulse
Width
VINIT
HD
Internal VD
Transfer Gate
Pulse
Discharge pulse
Composite
Video
Exposure Time
9H X
External pulse
VINIT
HD
Internal VD
Transfer Gate
Pulse
Purge pulse (discharge)
Composite
Video
9H
Exposure Time
min. 2H

OPERATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 13
3.1.3 (c) Internal Slow Reset Mode (Async Mode)
For Internal Slow Reset Mode, set the 10-position shutter speed dial switch from “5”to “8”. When the
external VINIT pulse is applied, internal VDis latched to Hd and a second internal VDsignal is
generated to set up the shutter speed period. Video output timing starts right after the second internal
VINIT.
FIGURE 8. Internal Slow Reset
External pulse
VINIT
HD
Internal VD
Transfer Gate
Pulse
Discharge pulse
Composite
Video
9H
EXPOSURE TIME
9H
min. 2H

OPERATION
Page 14 TM-6703 Progressive Scan Double Speed Shutter Camera
3.1.4 Progressive Scanning
The TM-6703 uses a state-of-the-art CCD called a “Progressive scanning interline transfer CCD”which
scans all lines sequentially from top to bottom at one frame rate (60 Hz). Like a non-interlace computer
screen, it generates a stable crisp image without alternating lines and provides full vertical TV
resolution of 484 lines. The interline transfer architecture is also important to generate simultaneous
shuttering. This is different from full frame transfer architecture which requires a mechanical shutter or
strobe light in order to freeze the object motion.
The TM-6703 outputs the progressive scanned image with an electronic shutter in three different modes.
These modes are selected via the switches on the rear panel of the camera.
1. Progressive scanning double speed output (Normal mode. Select N, O)
On the rear panel of the camera, select NRM (normal mode), N and O. This produces straight
forward signal output equivalent to non-interlace VGA format (60Hz). Real-time double speed
CCD output is converted through normal analog video processing into 75Ω1Vp-p output format.
2. Progressive scanning 120Hz output (Rear switches: N, T)
This mode provides 120Hz scanning of the full field of view, but with only 242 lines of vertical
resolution. The CCD signals of each row combine to scan 242 lines; the frame speed therefore is
120Hz of non-interlace video. The async reset, electronic shutter and integration function work as
normal. The analog output is the same as 75Ω, 1Vp-p format at the 120Hz rate.
3. Partial scanning output (Rear switches: P, T for 100 lines; P, O for 200 lines)
By selecting 100 line partial scan (P, T), the TM-6703 outputs the central 100 lines of video. It
repeats the same lines at a rate of 200 frames/sec. with the fast dump blanking of unused lines. The
asynchronous reset and electronic shutter functions are maintained at each partial scan.
By selecting 200 line partial scan (P, O), the TM-6703 outputs the central 200 lines of video at a
rate of 125 frames/sec. The partial scan keeps the same resolution as full progressive scan, but with
a narrower field of view.
TABLE 1. Scanning Mode Settings
Normal Mode N O (60Hz progressive scan)
Double Scan N T (120Hz progressive scan)
100 Line Scan P O (200Hz progressive scan)
200 Line Scan P T (125Hz progressive scan)

OPERATION
TM-6703 Progressive Scan Double Speed Shutter Camera Page 15
FIGURE 9. Scan Output
3.1.5 Option 7-2
In order to connect the TM-6703 camera to various frame grabbers, internal jumper settings allow the
TM-6703 to accept external HD and VD sync at double speed (fH = 31.468 KHz), or to output HD, VD
and pixel clock for variable scan frame grabbers. This option can be requested when ordering the TM-
6703.
FIGURE 10. I/O Jumpers
3.1.6 V-Sync Output Selection for Async Mode (OP51-2)
At async image capturing, some frame grabbers cannot take the specific frame when continuous video
sync presents. The TM-6703 video output is normally composite sync with frame rate V-sync regardless
of the actual image or blank image.When it is asynchronously reset, the newly reset V-sync may be
random to normal sync rate and can be very close to the regular rate V-sync. This may be problematic to
the frame grabber in capturing the correct image.By selecting the rear plate board jumper, the V-sync
output occurs only at the async reset, and no V-sync occurs until the next Vinit (async trigger) comes in.
The frame grabber can then look for this V-sync and capture the correct timing.
Normal scan
Partial scan
Fast dump
Center
100 lines
VD
VD (partial scan)
Center
of Image
W`1 (VD)
W2
W12
OUT
IN
OUT
IN
BOTTOM BOARD, TOP SIDE (HD)
Last connection
not used; do not
connect to this
position.
W2 W1
CLOCK
VIDEO
REAR BOARD (FACING INWARD)
Standard settings (inputs) Output se
t
Table of contents