q-Tech 1U Assembly instructions

HARDWARE INSTALLATION
MANUAL
www.qtech.ru
QSRV RMC Platform - Hardware installation manual 1.0

www.qtech.ru
This manual is the product technical manual of Qtech 1U dual cabinet server. It mainly introduces
the technical characteristics, system architecture, installation method and basic operation of this
product. Qtech 1U dual server is divided into 1U4 bay, 1U10 are available in various models. This
product features low energy consumption, flexible expansion, high reliability, easy management
and easy deployment.
This manual is for professional system integrators or professional technicians. This product
should only be installed and maintained by experienced technicians approved by QTECH LLC
MANUAL FRAMEWORK
Chapter 1 Safety Statement
This section describes some of the environmental conditions that need to be taken into account
when using this product, the precautions, and the description of the laws and regulations related
to the product.
Chapter 2 Product Introduction
This section provides the specifications of the major components of the system and describes
the main features of each model of the Qtech 1U Dual cabinet Server series.
Chapter 3 Installing System Components
This section describes the installation methods and major considerations for using the major
system components of the Qtech 1U Dual cabinet Server.
Chapter 4 System cabinet Installation
This section describes the procedures and precautions for installing the rack using the guide rails
provided with the Qtech 1U Dual cabinet Server.
Chapter 5 BIOS Parameter Setting Instructions
This chapter mainly introduces the system BIOS parameter settings and main functions.
Chapter 6 RAID Setup Instructions
This chapter mainly describes how to set up RAID.
Chapter 7 Rapid IPMI Deployment

www.qtech.ru
Оглавление
MANUAL FRAMEWORK 2
1. CHAPTER 1 SAFETY STATEMENT 1
1.1. General safety issues 1
1.2. Product toxic and hazardous substances or elements name and content identification table
2
1.3. Warning notice 4
1.4. Climate environment requirements 4
1.5. Other important description 5
2. CHAPTER 2 PRODUCT INTRODUCTION 6
2.1. System Introduction 6
2.2. System Configuration 6
System parameters 6
System structure 8
2.3. System model specifications 9
2.4. System Components Introduction 13
Chassis Structure 14
Front panel lights and buttons instructions 15
Rear Window Contruction 16
Motherboard components 17
Hard disk backplane assembly 23
Install rear backplane 2*2.5” 26
Hard disk label 28
Hard disk indicator 28
System fan 29
3. CHAPTER 3 INSTALLING SYSTEM COMPONENTS 30
3.1. CPU installation 30
1.3.1. 3.3 Installation of CPU radiator 34
3.2. 6. If you use an active cooling fan, please connect the fan power cord to the
motherboard socket marked as CPU0_FAN/CPU1_FAN.Memory installation 35
3.3. Hard disk installation 38
3.4. Fan module installation 42
3.5. Installation Steps of Two 2.5-inch Non-Hot Swappable Hard Disks 44
3.6. Introduction to front panel 48

www.qtech.ru
4. CHAPTER 4 SYSTEM CABINET INSTALLATION 51
5. CHAPTER 5 BIOS PARAMETER SETTING INSTRUCTIONS 55
5.1. Enter BIOS Setup interface 55
5.2. Setup menu parameter description 55
Main menu description 55
Advanced menu description 58
1.5.2. 3IntelRCSetup 65
2.5.2. Server Remote Management Menu (Server MGMT) 75
3.5.2. Security menu (Security) 77
1.5.2. Boot menu (Boot) 80
1.5.2. Exit BIOS menu (SAVE & EXIT) 81
6. CHAPTER 6 RAID SETUP INSTRUCTIONS 82
6.1. RAID function setting 82
1.6.1. RAID function description 82
2.6.1. 6.1.2 Install Hard Disk 85
3.6.1. 6.1.3 Set RAID options in BIOS 85
4.6.1. Intel® Rapid Storage Technology Enterprise SATA Option ROM Utility setup program 87
6.2. LSI SAS3008 Group RAID 93
Configuring RAID in UEFI Boot Mode 93
Legacy boot mode to configure RAID 106
6.3. LSI 9361-8i Group RAID 109
Configuring RAID in UEFI Boot Mode 109
Legacy boot mode to configure RAID 191
7. CHAPTER 7 RAPID IPMI DEPLOYMENT 209
7.1. Rapid deployment of IPMI 209
Make sure the motherboard supports IPMI functionality 209
Enter the BIOS settings IPMI function 209
7.2. IPMI function quickly explain 212
Enter the operation interface 212
IPMI Management System Content 213
KVM Remote Management Introduction 214
7.3. Other ways to connect IPMI 216
IPMI driver 216
IPMI tools and other open source software 216

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 1
www.qtech.ru
1.1. General safety issues
To prevent the risk of major personal and property damage, please be sure to follow the
suggestions below.
Do not open the cover of the system by yourself and it should be operated by a professionally
trained service technician. There may be a high voltage or electric shock on the triangular mark
with the lightning symbol. Do not touch it.
Remember to disconnect all cables before proceeding. (There may be more than one cable)
It is forbidden to carry out live operation such as starting up before the cover is closed.
When you need to open the lid, please wait for the internal equipment to cool before performing
it, otherwise it will be easy to cause burns to you.
Do not use this equipment in a humid environment.
If an extension cable needs to be used, use a three-wire cable and make sure it is properly
grounded.
Make sure the computer is well grounded. Different grounding methods can be used, but they
must be physically connected to the ground. If you are not sure if you have a safe grounding
protection, contact the appropriate agency or electrician for confirmation. If you need to reel
cable wiring, please contact QTECH Technology Co., Ltd. to provide advice.
Please use a three-core power cord and socket with grounding protection. Improper grounding
may result in leakage, explosion, or even personal injury.
Make sure that the power socket and the power socket are in close contact. Loose contact may
cause a fire.
Using your computer under AC voltage of 220V, working at unsuitable voltages may result in
electric shock, fire, and damage to the computer.
Require that the computer is well-ventilated and away from heat, sources of ignition, and do not
block the cooling fan, otherwise the computer may cause smoke, fire, or other damage due to
overheating.
If you smell or see the computer smoking, turn off the computer immediately and unplug the
power cord.
It is required that the power cord can be easily plugged in and unplugged from the power source
and the power outlet. Please keep the power cord and plug clean and undamaged, otherwise
there may be a risk of electric shock or fire.

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 2
www.qtech.ru
Note: If the battery is replaced incorrectly, there is a risk of explosion. Only use the
replacement of the same or equivalent type recommended by the manufacturer. The used
battery will cause environmental pollution. Replace the old battery and follow the
instructions.
Keep the computer away from electromagnetic fields.
Keep away from electronic noise caused by high-frequency safety equipment such as large air-
conditioning fans, large motor TV stations, and transmission towers.
Do not plug or unplug the backplane or move the computer while the computer is running. Doing
so may cause the computer to crash or damage the components.
Please try to avoid frequent restart or switch on and off to extend the life of your computer.
Please keep the environment clean and avoid dust. The working temperature of the equipment
is 10°C~35°C and the humidity is 35%~80%.
Please promptly back up important data. QTECH Technology Co., Ltd. is not responsible for data
loss caused by any situation.
This product uses an optical drive as a Class 1 laser device.
1.2. Product toxic and hazardous substances or elements name and content
identification table
During the 10-year environmental protection use period, toxic or harmful substances or
elements contained in the product will not leak or mutate under normal use conditions. Users
of electronic information products will not cause serious environmental pollution or Personal
and property causes serious damage.
Part Name
Harmful Substance
lead HG cadmiu
m
Hexavalen
t
chromium
Polybrominate
d biphenyls PBDE
(Pb) (Hg) (Cd) (Cr VI) (PBB) (PBDE)
Chassis/Baffle
X
O
O
O
O
O

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 3
www.qtech.ru
Mechanical
components
(fans, radiators,
motors, etc.)
X O O O O O
Printed Circuit
Components -
PCA*
X O O O O O
Cable/wire/con
nector
X O O O O O
Hard disk drive X O O O O O
Part Name
Harmful Substance
lead HG cadmiu
m
Hexavalen
t
chromium
Polybrominate
d biphenyls PBDE
(Pb) (Hg) (Cd) (Cr VI) (PBB) (PBDE)
Media
reading/storage
equipment
(disc, etc.)
X O O O O O
Power
Supply/Power
Adapter
X O O O O O
power cable
X
O
O
O
O
O
Pointing device
(mouse, etc.)
X O O O O O
keyboard
X
O
O
O
O
O

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 4
www.qtech.ru
UPS
X
O
O
O
O
O
Complete
cabinet / Rail
Products
X X O O O O
○ Indicates that the content of the toxic and hazardous substances in all homogeneous materials
of the component is below the limit requirements specified in GB/T 26572-2011 “Limitations for
Restricted Substances in Electrical and Electronic Products”.
× indicates that the content of the toxic and hazardous substances in at least one homogeneous
material of the component exceeds the limit requirements specified in GB/T 26572-2011
"Limitations for Restricted Substances in Electrical and Electronic Products". However, it
complies with the EU RoHS directive (including its exemption clause).
Note: This table shows the status of toxic and hazardous substances contained in all possible
parts of QTECH server, memory and workstation products. Customers can refer to this table
to check the situation of toxic and hazardous substances contained in the purchased parts.
1.3. Warning notice
This product complies with EMC Class A standards.
1.4. Climate environment requirements
The optimal working temperature of the equipment is 10°C-35°C; the maximum indoor
temperature of the equipment is 40°C.
System battery
3V CR2032 lithium battery.
Note: Some configurations have been verified for performance at 45°C and 90% (29°C
maximum dew point) humidity.
Temperature
Operating temperature 10 °C to 35 °C (50 °F to 95 °F) with a maximum temperature
gradient of 10 °C per hour
Continuous operating
temperature range (at
10 °C to 35 °C (50 °F to 95 °F) without direct sunlight.

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 5
www.qtech.ru
950 meters or 3117 feet
below altitude)
Storage temperature
range
–40°C to 65°C (–40°F to 149°F)
humidity
Storage With a maximum dew point of 33 °C (91 °F), the relative humidity
is 5% to 95%. The air must not condense at all times.
Continuous operation
humidity percentage
range
With a maximum dew point of 26 °C (78.8 °F), the relative
humidity is 10% to 80%.
If the computer is used in an environment where the lightning protection facilities are poor
or not, turn off the power and remove the power cord, network cable, and telephone line
connected to the computer in a thunderstorm.
Please use genuine operating system and software and configure it correctly. QTECH
Technology Co., Ltd. does not have maintenance responsibility for server failures caused by
operating systems and software.
Please do not disassemble the chassis and increase or decrease the server hardware
configuration. QTECH Technology Co., Ltd. is not responsible for the hardware and data
damage caused by this.
When a server fails, first check the Troubleshooting section of this manual to identify and
troubleshoot common problems. If you cannot determine the cause of the failure, please
contact QTECH Technology Co., Ltd. technical support department for assistance.
Choosing a suitable environment for the computer helps the computer run stably and can
extend the life of the computer.
QTECH Technology Co., Ltd. reserves the right of final interpretation of the above terms and
conditions
1.5. Other important description
"If the device is marked with an identifier, it means that the device affixed with this identifier is
designed and evaluated only at an altitude of 2000m. Therefore, it is only suitable for safe
use below 2000m. When it is used above 2000m, there may be a safety hazard."
“If this device is marked with this symbol, it means that the device affixed with this symbol is
only designed and evaluated for safety in non-tropical climate conditions. Therefore, it is
only applicable to the safe use of non-tropical climatic conditions and may be safe when
used in tropical climate conditions. Hidden trouble."

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 6
www.qtech.ru
2.1. System Introduction
The Qtech 1U server is a new generation of 1U dual cabinet server with a wide range of
applications that QTECH has developed for Internet, IDC (Internet Data Center), cloud
computing, enterprise market and telecom service applications. Suitable for IT core business,
cloud computing virtualization, high performance computing, distributed storage, big data
processing, enterprise or telecom service applications and other complex workloads. The server
has the advantages of low energy consumption, strong scalability, high reliability, easy
management, and easy deployment.
2.2. System Configuration
Qtech 1U products include 1U4 (3.5" hard disk), 1U10 (2.5" hard disk) disk type 3 kinds of models
in addition to the hard disk connection, compatible with the largest number of different hard
drives, other specifications are the same.
System parameters
Features
Technical specifications
model
1U
size
1U cabinet type, standard with guide rails, maximum depth: 640 mm
processor Supports 1 or 2 Intel Haswell-EP E5-2600 V3 series processor(135W
maximumly), Brodwell EP processoris compatible

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 7
www.qtech.ru
chipset
Intel® C612 Series Server-Specific Chipset
RAM
Each DIMM support 32GB(RDIMM)/64GB(LRDIMM)maximumly
Maximum 1024GB for whole motherboard DDR4 2133*/ 1866 /1600
/1333RDIMM/LRDIMM/NVDIMM
16pcs DIMM 8 channel ,support1024GB DDR4 maximumly
,2133MHz ECC RDIMM and LRUDIMM
Storage
controller
10x SATA 3.0 ports
Internal storage controller: PCH supports RAID 0\1\10&5
External HBA (non-RAID)
4-port 12Gb/s SAS passive backplane SGPIO
Drive bays
Front Bay: Up to 4 hot-swappable 3.5/2.5-inch SAS/SATA (HDD/SSD)
Front Bay: Up to 10 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
Rear Bay: Up to 2 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
power supply Platinum-class 550W, 770Whot swappable redundant power supply
External Port
& PCIE
Front port: 2 USB2.0
Rear: VGA, 4 USB3.0, 1 management network port, 4 RJ45 network ports,
or 2pcs 1000Mbps business net port,2pcs 10000Mbps business net port
PCIE expansion board: up to 6 PCIE third-generation slots HLHH
System fan 5*N+1 hot swap redundant fan
On motherboard: 8x 1X4 pin FAN Connector
The internet Two onboard 1GE, optional two 2 10GE interfaces
Onboard Dual Marvell 88E1512 1G PHY (Option INTEL X557-AT2 10G PHY )
safety
TPM/TCM (optional)
Chassis cover intrusion detection
Front panel with key lock
Locking the chassis cover

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 8
www.qtech.ru
management
1x RTL8211E-VB-CG Ethernet PHY
Onboard iBMC management module supporting management features
such as IPMI, SOL, KVM Over IP, and virtual media
Optional LCD Management Module
Virtualization
support
VMWare ESXi 6.0, Nutanix, Hyper-V
System structure
The main board features are as follows:
◆Latest Intel® Haswell platform matching with Dual Socket LGA2011 CPU and Intel Xeon
Processor E5-2600 V3 series processor;
◆Chipset has applied Intel Wellsburg C612;
◆E-ATX,12"X 13"(30.5cm x33cm);
◆16pcs DIMM 8 channel ,support1024GB DDR4 maximumly ,2133MHz ECC RDIMM and
LRUDIMM;
◆3pcs SATA3.0 6Gb ,and RAID 0, 1, 5,10 is supported;
◆Independent IPMI 1000Mbps management port to realise remote management , control
and iKVM function. BMC chip has applied Aspeed AST2400;
◆1pcs internal UID indicator light and power button with alarm function
◆4pcs USB3.0 interface,4pcs USB2.0 interface and 1pcs vertical internal USB3.0 Connector;
◆1pcs VGA port and 1pcs RS-232 port;
◆2pcs 10000Mbps network controller embedded i540 BT2 chip,2pcs 1000Mbps network
controller embedded Intel i210 chip +1 * Mgmt LAN;
◆The motherboard is put through strict quality controls, such as high temperature tests,
temperature cycling testes、alternating temperature humidity tests in different complex
conditions simulated by professional constant temperature and humidity testing equipment.
◆Motherboard passed the full load tests in the conditions of normal temperature and high
temperature through long time.
◆Power conversion efficiency of motherboard is more than 90% based on ultra/optical low
Rds(on) internal power MOSFET and optimized DC-DC switching power supply designation.
Customized BIOS can switch off needless capabilities in order to reduce power dissipation, fans
speed can be adjusted by BMC chip according to exact system temperature monitoring.The
system architecture board diagram is as follows:

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 9
www.qtech.ru
2.3. System model specifications
1U4 tray 3.5 inch disk model

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 10
www.qtech.ru
Features
Technical specifications
model
1U
size
1U cabinet type, standard with guide rails, maximum depth: 640 mm
processor Supports 1 or 2 Intel Haswell-EP E5-2600 V3 series processor(135W
maximumly), Brodwell EP processoris compatible
chipset
Intel® C612 Series Server-Specific Chipset
RAM
Each DIMM support 32GB(RDIMM)/64GB(LRDIMM)maximumly
Maximum 1024GB for whole motherboard DDR4 2133*/ 1866 /1600
/1333RDIMM/LRDIMM/NVDIMM
16pcs DIMM 8 channel ,support1024GB DDR4 maximumly
,2133MHz ECC RDIMM and LRUDIMM
Storage
controller
10x SATA 3.0 ports
Internal storage controller: PCH supports RAID 0\1\10&5
External HBA (non-RAID)
4-port 12Gb/s SAS passive backplane SGPIO

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 11
www.qtech.ru
Drive bays
Front Bay: Up to 4 hot-swappable 3.5/2.5-inch SAS/SATA (HDD/SSD)
Front Bay: Up to 10 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
Rear Bay: Up to 2 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
power supply Platinum-class 550W, 770Whot swappable redundant power supply
External Port
& PCIE
Front port: 2 USB2.0
Rear: VGA, 4 USB3.0, 1 management network port, 4 RJ45 network ports,
or 2pcs 1000Mbps business net port,2pcs 10000Mbps business net port
PCIE expansion board: up to 6 PCIE third-generation slots HLHH
System fan 5*N+1 hot swap redundant fan
On motherboard: 8x 1X4 pin FAN Connector
The internet Two onboard 1GE, optional two 2 10GE interfaces
Onboard Dual Marvell 88E1512 1G PHY (Option INTEL X557-AT2 10G PHY )
safety
TPM/TCM (optional)
Chassis cover intrusion detection
Front panel with key lock
Locking the chassis cover
management
1x RTL8211E-VB-CG Ethernet PHY
Onboard iBMC management module supporting management features
such as IPMI, SOL, KVM Over IP, and virtual media
Optional LCD Management Module
Virtualization
support
VMWare ESXi 6.0, Nutanix, Hyper-V

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 12
www.qtech.ru
1U10 2.5 inch disk type
Features
Technical specifications
model
1U
size
1U cabinet type, standard with guide rails, maximum depth: 640 mm
processor Supports 1 or 2 Intel Haswell-EP E5-2600 V3 series processor(135W
maximumly), Brodwell EP processoris compatible
chipset
Intel® C612 Series Server-Specific Chipset
RAM
Each DIMM support 32GB(RDIMM)/64GB(LRDIMM)maximumly
Maximum 1024GB for whole motherboard DDR4 2133*/ 1866 /1600
/1333RDIMM/LRDIMM/NVDIMM
16pcs DIMM 8 channel ,support1024GB DDR4 maximumly
,2133MHz ECC RDIMM and LRUDIMM
Storage
controller
10x SATA 3.0 ports
Internal storage controller: PCH supports RAID 0\1\10&5
External HBA (non-RAID)
10-port 12Gb/s SAS passive backplane SGPIO

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 13
www.qtech.ru
Drive bays
Front Bay: Up to 4 hot-swappable 3.5/2.5-inch SAS/SATA (HDD/SSD)
Front Bay: Up to 10 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
Rear Bay: Up to 2 hot-swappable 2.5-inch SAS/SATA (HDD/SSD)
power supply Platinum-class 550W, 770Whot swappable redundant power supply
External Port
& PCIE
Front port: 2 USB2.0
Rear: VGA, 4 USB3.0, 1 management network port, 4 RJ45 network ports,
or 2pcs 1000Mbps business net port,2pcs 10000Mbps business net port
PCIE expansion board: up to 6 PCIE third-generation slots HLHH
System fan 5*N+1 hot swap redundant fan
On motherboard: 8x 1X4 pin FAN Connector
The internet Two onboard 1GE, optional two 2 10GE interfaces
Onboard Dual Marvell 88E1512 1G PHY (Option INTEL X557-AT2 10G PHY )
safety
TPM/TCM (optional)
Chassis cover intrusion detection
Front panel with key lock
Locking the chassis cover
management
1x RTL8211E-VB-CG Ethernet PHY
Onboard iBMC management module supporting management features
such as IPMI, SOL, KVM Over IP, and virtual media
Optional LCD Management Module
Virtualization
support
VMWare ESXi 6.0, Nutanix, Hyper-V
2.4. System Components Introduction

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 14
www.qtech.ru
Chassis Structure
No.
Description
1
Base
2
Rear Windows
3
Ventilation wall
4
Hard disk module
5
Front cover
6
Top cover
7
Handle
8
Hard Drive bracket
9
Fan

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 15
www.qtech.ru
Front panel lights and buttons instructions
LED Status Description
No
.
Picture LED Appearance Description
①
-- LOGO label (labeling or
customized acrylic label)
②
The green light is on The device is on
③
Reset The button is used to
restart the server

Hardware installation manual
Qtech Platform 2U Server Product Technical Manual 16
www.qtech.ru
④
The green light
flashes
The system is running
normally
⑤
The yellow light is on Alarm indication,
including system alarm, fan
alarm, power alarm, etc.;
the specific
can be viewed
through IPMI management
software
⑥
The green light is on Internet access 1
connection is normal
⑦
The green light is on Internet access 2
connection is normal
⑧
USB interface 2*USB2.0 interface
Rear Window Contruction
1 Power Site/2*Hot-Spare 2.5'' bay (with CRPS)
2 IO washer position
3 Expansion slot
Explanation:
2*Hot-Spare 2.5'' bay can install only with CRPS redundant power supply.
This manual suits for next models
2
Table of contents
Other q-Tech Server manuals
Popular Server manuals by other brands

Dell
Dell FC4700 Setup guide

NEC
NEC Express5800/R120f-1E USE PRECAUTIONS

Compaq
Compaq 1850R - ProLiant - 128 MB RAM Setup and installation guide

DEC
DEC DECstation 5000 Model 100 Series Maintenance Guide

Lenovo
Lenovo ThinkServer RD230 Installation and user guide

Dell
Dell PowerEdge FC630 Getting Started With Your System