manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Qlight
  6. •
  7. Floodlight
  8. •
  9. Qlight S125TL User manual

Qlight S125TL User manual

1
Ø125mm Large-Sized Stackable Signal Light
S125TL
5030
44
※ Customized color arrangements available.
• Protection rating : IP44
• Ambient operating temperature : -30°C to +50°C
Model
number Layer
Voltage Current
Certicate
Weight
Color
S125TL
1
DC12V
-24V
Max.
0.300A
-
0.62kg
R-Red
AC110V
0.080A
0.84kg
AC220V
0.040A
2
DC12V
-24V
Max.
0.600A
0.88kg
R-Red
G-Green
AC110V
0.105A
1.11kg
AC220V
0.055A
3
DC12V
-24V
Max.
0.900A
1.15kg R-Red
A-Amber
G-Green
AC110V
0.140A
1.38kg
AC220V
0.070A
S125TL - 3 - 24 - RAG
[Model
number] [Layer] [Voltage] [Color]
| | | |
• S125TL
• 1-1Layer
• 2-2Layers
• 3-3Layers
• 12/24
- DC12V-24V
• 110 - AC110V
• 220 - AC220V
R-Red
A-Amber
G-Green
Please scan the QR
code for more
detailed
product information.
www.qlight.com
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specication.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, re, electric shock and loss of life.)
Product Specications
Ordering Specications
2
• External power line - UL1015 AWG18(0.75sq) × 2C 400mm
• External signal line - UL1007 AWG22(0.3sq) 400mm
S125TL
100 100
Ø125
3395
Layer
295
195
2
1
L
48
12
140
PCD 85
360°/3-M5 BOLT
Ø10 CABLE ENTRY
L
Wiring Instructions
Wiring Instructions
S125TL-DC S125TL-AC
S125TL-DC
• S125TL
can be wired with either external contact or transistor.
•
When using a transistor, please choose between the NPN transistor or PNP transistor which best matches the voltage and product type,
then connect them correctly according to the wiring diagram below.
• S125TS which uses a xenon lamp can not be connected by using transistor. Please use an external contact.
1
2
3
1
2
3
1
2
3
1
2
3
EXTERNAL CONTACT EXTERNAL CONTACT
EXTERNAL TRANSISTOR-NPN EXTERNAL TRANSISTOR-PNP
Red
Amber
Green
Black
Red
Amber
Green
Black
Red
Amber
Green
Black
Red
Amber
Green
Black
White
Black
Layer1
Layer2
Layer3
Layer1
Layer2
Layer3
Layer1
Layer2
Layer3
Layer1
Layer2
Layer3
POWER
POWER POWER
POWER
COMMON
Fuse Fuse
Steady Steady
Fuse Fuse
Dimensions
(Units : mm)
3
①
PCD 85
Min.Ø5 CABLE ENTRY
3-Ø6 HOLES
Parts Denition/ Installation/ Light Function Selection
Mounting Hole Specications/ Xenon Bulb Replacement lnstructions
• remove the ange nuts from bolts and place the product through the mounting surface holes.
• Fasten the ange nuts on the opposite side of the mounting surface until the product is tightened securely.
•• Please refer to the chart below to use light function
selection switch(①) located inside the product.
■
Parts Denition
■
Installation
■ Light Function Selection
Lens(AS)
Reector
(Heat resistant ABS)
Housing(ABS)
Rubber spacer
Flatwasher
Flange nut
LED
•
Machine holes on the mounting surface referring to the
diagram below.
■
Mounting Hole Specications
■
Xenon Bulb Replacement instructions(S125TS only)
• Default function is set at steady LED. Select the desired function
for your application during installation.
▶
L :
Steady
▶
LF : Flash
• Please wait at least 30 mimutes after turning off the power
before replacing the xenon bulb.
•
Please pull out the entire xenon bulb structure ① to disassemble.
•
For xenon bulb assembly, please ensure the connector portion
of the xenon bulb structure matches the pin location
②.
①
②
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP44.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP44), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
•
For further information, please visit our website (www.qlight.com).
Disassemble
bulb Assemble
bulb
Qlight Co., Ltd. www.qlight.com | [email protected]
Head Ofce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea Tel. +82-80-328-2222 Fax : +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-80-328-1111
Qlight Overseas Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Ofce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-245-0017
Qlight USA, Inc. www.qlight.com www.qlightusa.com | [email protected]
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1.408.519.5740 Fax. +1.408.519.5739
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | [email protected]
China Factory/ Shanghai Sales Ofce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86.21.6651.7100 Fax. +86.21.6315.3929
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
For your safety
Specication and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - S125TL -1911A

This manual suits for next models

2

Popular Floodlight manuals by other brands

MIIDEX LIGHTING VISION-EL PAR56 Notice Instructions

MIIDEX LIGHTING

MIIDEX LIGHTING VISION-EL PAR56 Notice Instructions

Robus RCM9030AS-04 instructions

Robus

Robus RCM9030AS-04 instructions

AEL ACP Installation & maintenance instructions

AEL

AEL ACP Installation & maintenance instructions

Martec OPAL Series installation guide

Martec

Martec OPAL Series installation guide

Lena Lighting MAGNUM FUTURE LED XL Installation instruction

Lena Lighting

Lena Lighting MAGNUM FUTURE LED XL Installation instruction

Pro-Elec SR09941 manual

Pro-Elec

Pro-Elec SR09941 manual

Cooper Lighting Regent CMSRU180W instruction manual

Cooper Lighting

Cooper Lighting Regent CMSRU180W instruction manual

SImx Mightylite LHT0230 installation guide

SImx

SImx Mightylite LHT0230 installation guide

Afrison 6 Series installation instructions

Afrison

Afrison 6 Series installation instructions

Sealey LED190T instructions

Sealey

Sealey LED190T instructions

JB Systems LED jive Operation manual

JB Systems

JB Systems LED jive Operation manual

Wetelux 90 08 22 Original instructions

Wetelux

Wetelux 90 08 22 Original instructions

Flash F7100087 user manual

Flash

Flash F7100087 user manual

Pure Reliability SOLO 250 manual

Pure Reliability

Pure Reliability SOLO 250 manual

thomann Stairville LED Flood 50W user manual

thomann

thomann Stairville LED Flood 50W user manual

Cooper Crouse-Hinds CEAG SEB 8 operating instructions

Cooper Crouse-Hinds

Cooper Crouse-Hinds CEAG SEB 8 operating instructions

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

Ecosense EcoSpec installation manual

Ecosense

Ecosense EcoSpec installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.