1. Set therotaryswitchto Ωrange.
2.Connectthetestleadstothecircuitorresistorbeingmeasured and
read thedisplayedvalue.
DiodeTest
1. Set therotaryswitchto range.
2.Forforward-biasreadingsonanysemiconductorcomponent, place
thered testleadon thecomponent'sanodeand placetheblacktest
lead onthecomponent'scathode.
3.Themeterwill showtheapprox.forwardvoltageofthediode
AudibleContinuityTest
1. Set therotaryswitchto range.
2.Connectthetestleadstotheresistanceinthecircuitbeing
measured.
3.Whenthetest lead tothecircuit isbelow50Ω, acontinuousbeeping
will indicateit.
KEYFUNCTION
HoldKey
DataHoldmodemakesthemeterstop updatingthedisplay.Enabling
DataHoldfunction inautorangemodemakesthemeterswitchto
Manualrangingmode,butthefull-scalerangeremainsthesame.Data
Holdfunctioncan becancelled bychanging themeasurementmode,
pressing RANGE key, orpush HOLD keyagain.
Toenterandexit theDataHoldmode:
1. Press HOLD key(short press). Fixesthedisplayon thecurrent value,
DH isdisplayed.
2.A secondshort pressreturnsthemetertonormalmode.
SelectKey
1. Switchesbetween dcand acvoltageorcurrent.
2. Disablesautomaticpower-off feature.
BATTERYSAVER
TheMeterentersthe"sleep mode"andblanks thedisplayiftheMeteris
on but not usedfor30 minutes.
Pressthe HOLD keyorrotatetherotaryswitchtowakethemeterup.
TodisabletheSleep mode,holddownthe SELECT functionkeywhile
turningthemeteron.
BEEPERINDICATION
Whenpressthefunctionkeyandifit isvalid,abeep will beemitted. The
buzzerwill soundfivetimesoneminutebeforeautopoweroff.And a
long sound toshowtheautopoweroff.Inthecontinuitymeasuring
status, iftheresistanceissmallerthan 50Ω,thebuzzerwill sound.
BATTERY&FUSE REPLACEMENT
ToreplacetheMeter'sbattery:
Ifthesign"BATT" appearson theLCDdisplay,itindicatesthatthe
batteryshouldbereplaced.Removethescrewonthebackcoverand
openthebatterycase.Replacetheexhaustedbatterieswithtwonew
1.5V batteriesofthesametype(SR44).
ToreplacetheMeter'sfuse:
Fuserarelyneedreplacementandblowalmostalwaysasaresultof
operator serror.Open thecaseandreplacetheblownfusewiththe
samerating specified: F500mA/250V ∅5×20.
WARNING!
Beforeattempting toopen thecase,always besurethattestleadshave
beendisconnected frommeasurementcircuits.Closecaseand tighten
screwscompletelybeforeusingthemetertoavoidelectricalshock
hazard.
ACCESSORIES
Battery1.5V (SR44)2
Carrying Case1
Operating manual1
WLS040