Quatro Premium SPM504 Manual

Filename: O&M/SPM
Operations & Maintenance Manual
Model: SPM504
Premium Brushless Solder Pure Multi User Fume Capture
1.0 IMPORTANT:
Save shipping box and foam for future service. Shipping without proper foam will cause damage to unit.
2.0 SAFETY PRECAUTIONS
Carefully read instructions in this manual before operation (keep manual as it contains information for proper operation and maintenance). Keep all fastening hardware
tight to ensure that the unit is in safe workingcondition. Familiarise yourself with the way in which the special filter is removed, installed, and serviced. Filter must be in
place whenever this machine is in operation. Use only on grounded electrical circuit; do not use two-wire electrical prong adapters to defeat the three-pronged plug on
the end of the cord. When servicing motor, be careful when touching exterior of motor when it is turned off; it maybe hot enough to be painful or cause injury. Do not
substitute any other filter for the one supplied, as it will alter the design characteristics. UNPLUG UNIT FROM ITS POWER SUPPLY PRIOR TO SERVICING!
3.0 SYSTEM COMPONENTS
Description
SPM504-1
SPM504-2
SPM504-3
SPM504-4
SPM504-5
Airflow (Free Air)
475
475
475
475
475
Stage 1 Filter (Dust)
F265
F007
F007
F007
F007
Stage 2 Filter (HEPA)
F357
F357
F022
F357
n/a
Stage 3 Filter (ODOR)
F033-GPC
F045-GPC
F033-GPC
F045-GPC
F033-GPC (2x)
Dimensions, Height:
30” (762mm)
30” (762mm)
30” (762mm)
30” (762mm)
30” (762mm)
Dimensions, Width:
23” (585mm)
23” (585mm)
23” (585mm)
23” (585mm)
23” (585mm)
Dimensions Depth:
15” (381mm)
15” (381mm)
15” (381mm)
15” (381mm)
15” (381mm)
Voltage / Current:
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
120/1/60, 9.2amps
Max. Power, approx. Weight:
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
740watts, 180lbs (82kgs)
4.0 UNIT INSPECTION
Upon receipt, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
If you suspect concealed damages inside the box indicate so on the transport companies’ shipping documents.
5.0 ASSEMBLY
Unit is shipped in 1 box:
- Remove cardboard packaging
- Lift unit off the pallet and place is required location
- Open Front Filter door, remove Manual, Power cord set AND REMOVE PLASTIC from HEPA Filter
6.0 PRE START-UP CHECKLIST
a) Check that all internal components are present and are adequately supported;
b) Open Front Filter Access Door and ensure filters are positioned as per photo below
c) Check that labels and serial numbers are present for future identification;
d) Verify power supply is compatiblewith equipment (120-volt/1 phase/60hz). Check that the unit is plugged into a grounded receptacle;
e) Ensure that rubber grommets are tight and secure prior to placing unit on the floor.
7.0 START-UP
a) Ensure door closes tightly; b) Insert male end of cord into wall outlet. Unit should be connected to an independent circuit;
c) Switch power toggle to "ON" position to ensure system operation.
WARNING: DO NOT OPERATE UNIT UNLESS FILTER IS IN PLACE.

QUATRO
Air Technologies Inc.
SPM-----------------------------------------------------------------------------------------------------
”We Make Clean Air”
30 Hymus Boulevard, Montreal, Quebec, H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454
info@quatro-air.com website: www.quatro-air.com
2
8.0 EQUIPMENT MAINTENANCE PROCEDURES
Proper maintenance is critical in extending life of unit. The information presented below outlines basic maintenance procedures ensuring the SPM unit will provide
trouble-free operation in future. TheSPM is designed to allow quick access to the filters.
Blowers and motors which DO NOT require service ona regular basis, arelocated underneath the unit.
9.0 TROUBLESHOOTING
Symptoms
Possible Cause
Suggested Solution
Unit will not start
- Faulty Power supply
- Blown fuse
- Unit not plugged into receptacle
- Check breaker box
- Replace fuse
- Plug unit in
Excessive noise
- Blower wheel contacting blower, housing or cone
- Motor bearings are worn
- Realign/replace wheel
- replace motor
Insufficient airflow
- Obstruction in system
- Clogged Dust Pad
- Clogged Filter Bag
- Clogged HEPA Filter
- Remove obstruction
- Replace filters
- Replace filters
- Replace filter
Motor Shuts off, then back on after 30 minutes
- Motor Amp Draw too high
- ensure filter is in place
Excessive airflow
- Filter not in place
- Install filter
10.0 WARRANTY
QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of one year from
date of shipment. QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall be demonstrated to have been defective.
This is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage. No
person, firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods. Equipment, parts and material
manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO
Air Technologies Inc.
Conditions and Limitations: This warranty does not cover abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, fear
wear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at voltages
other than those specified by QUATRO Air Technologies Inc.
This manual suits for next models
5
Other Quatro Vacuum Cleaner manuals