Quins LC20 User manual

Manual
Release: 06 / 2019
Quins LC20
Quins LC20/UV
Quins LC25
Quins LCM20
Quins LCM20/UV
Quins LCM25
Quins Hardware
www.quins.de

Release: 06 / 2019
Address / Central
page - 2 -
Address / Central
-Service
Owner: Klaus Kornhaas
Wohnpark 1
95189 Brunnenthal
Germany
Phone: ++49 (0) 9281 67212
Fax: ++49 (0) 9281 62635
URL: www.quins.de
FTP-downloads at:
ftp://Quins-Support.de

Release: 06 / 2019
INDEX
Address / Central-Service
................................
INDEX ................................
................................
Driver Installation
................................
Variants: ................................
................................
Installation:
................................
Scanner is not recognized:
................................
Quins-Support:
................................
Registration / Licensing
................................
Updates / Downloads
................................
Scanner Settings
................................
Scan Systems Settings / Ad
justment
QuinsBox LC20 / LC20UV
................................
Connections................................
................................
Control elements
................................
LC20 + 25 / LCM20 + LCM25
................................
LC20/UV / LCM20/UV
................................
Transport safety
................................
Drawer................................
................................
Inserting assemblies for testing
................................
2 levels ................................
................................
Maintenance work
................................
Quins System LCM20 / LCM20UV
................................
Connections................................
................................
Fuse ................................
................................
Rollers with brakes
................................
Control elements
................................
Quins computer
................................
QuinsBox LC25 -
Quins System LCM25
Connections................................
................................
Control elements
................................
Transport safety
................................
Drawer................................
................................
Maintenance work
................................
Decleration of Conformity
................................
Technical data of the Quins hardware
page - 3 -
................................
................................................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................................................
................................
justment
................................................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................................................
................................
Quins System LCM25
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................................................
................................
................................
................................
................................
................................
................................................................
................................
................................
................................................................
................................
Technical data of the Quins hardware
................................................................
................................
................................
..... 2
................................
..... 3
................................
.................. 4
................................
.......................... 4
................................
...................... 4
................................
.............................. 4
................................
................ 4
................................
....... 5
................................
.......... 6
................................
................. 7
................................
............... 7
................................
..... 8
................................
......................... 8
................................
................. 8
................................
.......................... 8
................................
..... 8
................................
................... 8
................................
................................. 9
................................
........................... 9
................................
.......................... 10
................................
............. 10
................................
...................... 10
................................
....................... 10
................................
.............................. 10
................................
........ 10
................................
............... 10
................................
................... 11
................................
............ 11
................................
....................... 11
................................
............... 11
................................
................. 11
................................
............................... 11
................................
............. 11
................................
... 12
................................
............... 13

Release: 06 / 2019
Driver
Installation
Variants:
For the use of the Quins hardware always the respective driver program must be
The correct Twain drivers are included in the corresponding EPSON
With this program, the Quins hardware can be operated without Quins programs, as a normal scanner.
Verwenden Sie das entsprechende Epson Scan
LC20 und LC20/UV:
EPSON GT
LC25:
EPSON GT
LCM20 und LCM25/UV:
EPSON GT
LCM25:
EPSON GT
On the Quins computer, in the
Quins
installation files are available or you can download them from our website.
https://www.quins.de/QuinsWeb/login.js
In the menu "Manuals" of the program "Quins professional"
The QuinsBox LC10 / 100 (EPSON GT-
10000) is the older model with SCSI connector,
but is no longer produced!
Installation:
Unzip the downloaded ZIP file and execute the included exe file
"run as administrator"!
Please note:
The possibly already connected box must
After completing the software installation, turn on the QuinsBox and restart the Quins computer.
Windows 7 and Windows 10 automatically detect the attached
imaging device in Device Manager.
Scanner is not recognized:
If the QuinsBox does not work, check in the Device Manager to see if the
operating system has also detected the hardware. Possibly. Maybe you
installed the wrong version or th
e hardware connection is defective!
If the hardware was recognized by the operating system, it can also be
used.
Otherwise the QuinsBox is defect and the red error LED is lit or
flashing.
Quins-Support:
We are happy to help you with
If your computer is connected to the internet,
we’re able to connect online, and give
Also we can support you by updating, backuping, or data base
management,
installations of additionally workstations, and all others.
With existing "software usage contract" an online support is basically free!
page - 4 -
Installation
For the use of the Quins hardware always the respective driver program must be
installed!
The correct Twain drivers are included in the corresponding EPSON
-Scan programs.
With this program, the Quins hardware can be operated without Quins programs, as a normal scanner.
Verwenden Sie das entsprechende Epson Scan
-Programm für die jeweilige Quins-
Hardware
EPSON GT
-15000 (LC20-31317eu.exe)
EPSON GT
-15000 (LC20-31317eu.exe)
EPSON GT
-20000 (LCM20-324775eu.exe)
EPSON GT
-20000 (LCM20-324775eu.exe)
Quins
-Install V5 \ Software \
Epson directory or on the Quins installation stick, the
installation files are available or you can download them from our website.
https://www.quins.de/QuinsWeb/login.js
p
In the menu "Manuals" of the program "Quins professional"
10000) is the older model with SCSI connector,
Unzip the downloaded ZIP file and execute the included exe file
by
The possibly already connected box must
NOT be switched on!
After completing the software installation, turn on the QuinsBox and restart the Quins computer.
Windows 7 and Windows 10 automatically detect the attached
hardware and enable the
If the QuinsBox does not work, check in the Device Manager to see if the
operating system has also detected the hardware. Possibly. Maybe you
e hardware connection is defective!
If the hardware was recognized by the operating system, it can also be
Otherwise the QuinsBox is defect and the red error LED is lit or
We are happy to help you with
Quins-support online!
If your computer is connected to the internet,
we’re able to connect online, and give
– HELP -- !
Also we can support you by updating, backuping, or data base
installations of additionally workstations, and all others.
With existing "software usage contract" an online support is basically free!
With this program, the Quins hardware can be operated without Quins programs, as a normal scanner.
Hardware
:
Epson directory or on the Quins installation stick, the
After completing the software installation, turn on the QuinsBox and restart the Quins computer.

Release: 06 / 2019
Registration / Licensing
You have a fully functional Tril version with the installation and can test these 30 days (today + 29 days). If the
Quins software was already
installed on this computer, it will be recognized by the software but the test time will
always be calculated from the first installation!
Please note:
a date manipulation on the computer automatically leads to the blocking of the software and
can only be
repaired for a fee! Also, the uninstallation and reinstallation does not change anything!
You should therefore activate the software in good time before the end of the test phase.
You need the license file
"QuinsLicense.lic"
You will
receive the license file by sending us your order and the key file created with our software;
to
You must first create this keyfile with our software:
At the end of the test phase, this window
Press the green button for "Yes" to start the key generator.
Start it during the test phase in the menu
„Settings“
„Registration“
Press button „Generate Key“.
The Key-Generator will be started:
You will then receive the desired license in accordance with our terms and conditions to your registered and
known e-mail address..
After receiving the file "QuinsLicense.lic" proceed as described in the e
Or select this file in the "Regi
stration"
"Register" button.
Your software is then unlocked with the purchased modules,
or the desired modules for a new test phase free.
page - 5 -
Registration / Licensing
You have a fully functional Tril version with the installation and can test these 30 days (today + 29 days). If the
installed on this computer, it will be recognized by the software but the test time will
always be calculated from the first installation!
a date manipulation on the computer automatically leads to the blocking of the software and
repaired for a fee! Also, the uninstallation and reinstallation does not change anything!
You should therefore activate the software in good time before the end of the test phase.
"QuinsLicense.lic"
for your computer.
receive the license file by sending us your order and the key file created with our software;
You must first create this keyfile with our software:
At the end of the test phase, this window
appears.
Press the green button for "Yes" to start the key generator.
Start it during the test phase in the menu
„Registration“
press button „Generate Key“
, the key
If you press the "I am offline"
button and
then the green "Save File"
button, then
you can save the key file.
Please send the saved file with your corresponding order or
You will then receive the desired license in accordance with our terms and conditions to your registered and
After receiving the file "QuinsLicense.lic" proceed as described in the e
-mail.
stration"
window under "Choose your license"
, and click on the
Your software is then unlocked with the purchased modules,
or the desired modules for a new test phase free.
You have a fully functional Tril version with the installation and can test these 30 days (today + 29 days). If the
installed on this computer, it will be recognized by the software but the test time will
a date manipulation on the computer automatically leads to the blocking of the software and
repaired for a fee! Also, the uninstallation and reinstallation does not change anything!
receive the license file by sending us your order and the key file created with our software;
, the key
will be generated.
button and
button, then
Please send the saved file with your corresponding order or
You will then receive the desired license in accordance with our terms and conditions to your registered and
, and click on the

Release: 06 / 2019
Updates / Downloads
You will informs regularly by e-
mail about new updates (program enhancements / bug fixes)
if you register with us.
Of course, these data are used exclusively for technical information only and not for promotional purposes.
Your data will be kept confidential and not disclosed to third
Please complete this form and send it return to us:
via Email:
support@quins.de
Please send technical update information to:
Company:
_____________________________________________________________
Address:
_____________________________________________________________
_________ / ___________________________________________________
responsible:
Mr. / Mrs. ____________________________________________________
E-mail:
_________________________________________
and to:
responsible:
Mr. / Mrs. ____________________________________________________
E-mail:
_____________________________________________________________
and
responsible: Mr. / Mrs.
____________________________________________________
E-mail:
_____________________________________________________________
All our current software solutions, updates, manuals and documentation can be downloaded for free from our
website. In the section "Download"
you register once
that you can always log in there in the future and download the latest updates and documentation.:
page - 6 -
mail about new updates (program enhancements / bug fixes)
Of course, these data are used exclusively for technical information only and not for promotional purposes.
Your data will be kept confidential and not disclosed to third
parties!
Please complete this form and send it return to us:
support@quins.de
Please send technical update information to:
_____________________________________________________________
_____________________________________________________________
_________ / ___________________________________________________
Mr. / Mrs. ____________________________________________________
_________________________________________
____________________
Mr. / Mrs. ____________________________________________________
_____________________________________________________________
____________________________________________________
_____________________________________________________________
All our current software solutions, updates, manuals and documentation can be downloaded for free from our
you register once
. You will automatically receive a password by e
that you can always log in there in the future and download the latest updates and documentation.:
http://www.quins.de
mail about new updates (program enhancements / bug fixes)
Of course, these data are used exclusively for technical information only and not for promotional purposes.
_____________________________________________________________
_____________________________________________________________
_________ / ___________________________________________________
Mr. / Mrs. ____________________________________________________
____________________
Mr. / Mrs. ____________________________________________________
_____________________________________________________________
____________________________________________________
_____________________________________________________________
All our current software solutions, updates, manuals and documentation can be downloaded for free from our
. You will automatically receive a password by e
-mail so
that you can always log in there in the future and download the latest updates and documentation.:

Release: 06 / 2019
Scanner Settings
In the "Reference Scan" window, you must set the data of the QuinsBox once!
Scan Systems Settings / Adjustment
In the top line, the correct Quins Box type, "Scan System"
must be selected, so that the scan program accesses the
correct hardware driver.
The "Map" settings are only intended for the old Quins boxes
LC10 / 100, for the current types of the LC20 / LC25 and LCM20
series these parameters have to be deactivated!
In this window, the dimensional accuracy
is entered. Take over the values
of the "Adjustment" label which is set
on the right side of your Quins box.
Please note:
if you reinstall the Quins software, or if you connect another Quins box
to the system computer, these
entries
page - 7 -
Scanner Settings
In the "Reference Scan" window, you must set the data of the QuinsBox once!
Scan Systems Settings / Adjustment
In the top line, the correct Quins Box type, "Scan System"
must be selected, so that the scan program accesses the
The "Map" settings are only intended for the old Quins boxes
LC10 / 100, for the current types of the LC20 / LC25 and LCM20
series these parameters have to be deactivated!
In this window, the dimensional accuracy
of the connected Quins box
of the "Adjustment" label which is set
if you reinstall the Quins software, or if you connect another Quins box
entries
must be corrected accordingly!

Release: 06 / 2019
QuinsBox LC20 / LC20UV
Connections
Unlock the transport lock and plug the power cord into
the appropriate port.
All Quins Boxes have a USB 2.0
port.
Only connect the box to a USB 2.0
slot (black socket)
on your system computer.
When connecting to a 3.0 slot (blue socket), there are driver
and transmission problems that can lead to error messages and
crashes!
Applies to all LC20, LCM20, -
/UV, and LCM25 models
Control elements
LC20 + 25 / LCM20 + LCM25
On / Off
After switching on, the carriage will move to the starting position and the scanner will
be initialized (white balance). As long as the initialization is not completed, the green
LED flashes and the scanner is not read
The scanner is only finished and will be recognized by Windows after the green LED
is constantly lit.
LC20/UV / LCM20/UV
In addition to the o.g. On / off switch, the UV box has the buttons to
- UV on
- White on
Depending on which key you
press, the corresponding lighting is activated.
In UV mode, the scanner will first start with the white light, initialize and then
automatically switch to UV.
You can always switch to a different light type. This will be activated at the next
scan start.
Transport safety
Attention:
t
o transport the QuinsBox, you should sna
so that the scan carriage does not mov
can be broken off.
When shipping the box, the transport lock
Applies to all LC models!
page - 8 -
QuinsBox LC20 / LC20UV
Unlock the transport lock and plug the power cord into
port.
slot (black socket)
When connecting to a 3.0 slot (blue socket), there are driver
and transmission problems that can lead to error messages and
/UV, and LCM25 models
.
After switching on, the carriage will move to the starting position and the scanner will
be initialized (white balance). As long as the initialization is not completed, the green
LED flashes and the scanner is not read
y yet.
The scanner is only finished and will be recognized by Windows after the green LED
In addition to the o.g. On / off switch, the UV box has the buttons to
:
press, the corresponding lighting is activated.
In UV mode, the scanner will first start with the white light, initialize and then
You can always switch to a different light type. This will be activated at the next
o transport the QuinsBox, you should sna
p the transport lock into place
so that the scan carriage does not mov
e uncontrollably and the guides
When shipping the box, the transport lock
MUST be locked!

Release: 06 / 2019
Drawer
Behind the drawer is located on each side of a stop bracket with magnet, which
hold the drawer when inserted in the end position. The drawer must always be
up to the stop, it means until the magnets hold them. If this
there may have been some object behind the drawer and disturbing, or the
stop angle are shifted / twisted. Both result in malfunctions
scanner cann
ot scan at the specified position
For troubleshooting and maintenan
ce, the drawer can be removed completely
from the QuinsBox. Simply press the black levers on one side up, the other side
down and pull out the drawer completely
When pushing back, make sure that the guide rail with the ball bearings has
also been insert
ed and received exactly in the mutual track. With a little
pressure, push the drawer all the way completely back and check
that it is easy to move.
Applies to all LC20, LCM20, -
/UV, and LCM25 models
Inserting assemblies for testing
The drawer
has a support angle with a groove under the round rod.
This groove serves to fix the assembly if it has been distorted during
soldering.
Please note that the front stop is located at the very edge of the scan area and
there the largest perspective o
ffset is possible! With high components in the
edge area and smaller components on the outside, these can be covered. In
this case, we recommend placing the assembly in the middle of the drawer.
For this purpose, a centre mark is attached to the longitudin
this centre mark within your reference image so that you can easily determine
where the assembly was inserted by repeatedly using the reference.
The side stops should be adjusted with a small distance, so that the
assemblies can be
easily inserted and removed. Make sure that the assembly
is not moved when moving the drawer in
The magnetic-
foot stopper is normally required for the free
the assembly.
Applies to all LC20, LCM20, -
/UV, and LCM25 models
page - 9 -
Behind the drawer is located on each side of a stop bracket with magnet, which
hold the drawer when inserted in the end position. The drawer must always be
up to the stop, it means until the magnets hold them. If this
is not possible,
there may have been some object behind the drawer and disturbing, or the
stop angle are shifted / twisted. Both result in malfunctions
in operation as the
ot scan at the specified position
.
ce, the drawer can be removed completely
from the QuinsBox. Simply press the black levers on one side up, the other side
down and pull out the drawer completely
.
When pushing back, make sure that the guide rail with the ball bearings has
ed and received exactly in the mutual track. With a little
pressure, push the drawer all the way completely back and check
/UV, and LCM25 models
.
Inserting assemblies for testing
has a support angle with a groove under the round rod.
This groove serves to fix the assembly if it has been distorted during
Please note that the front stop is located at the very edge of the scan area and
ffset is possible! With high components in the
edge area and smaller components on the outside, these can be covered. In
this case, we recommend placing the assembly in the middle of the drawer.
For this purpose, a centre mark is attached to the longitudin
al rail. Always scan
this centre mark within your reference image so that you can easily determine
where the assembly was inserted by repeatedly using the reference.
The side stops should be adjusted with a small distance, so that the
easily inserted and removed. Make sure that the assembly
is not moved when moving the drawer in
.
foot stopper is normally required for the free
-floating corner of
/UV, and LCM25 models
.

Release: 06 / 2019
2 levels
The module support has 2 levels:
- the SMD level, f
or a focus of 100% (optimum sharpness), the
support is provided on the two angle strips with a clearance height of
about 50 mm.
- the THT level,
with a reduced focus at the bottom PCB level of th
assembly (unsuitable for SMD component testing) is the support on
the lower lugs of the side stops and the magnetic
level is intended for assemblies with high THT components with a
clearance height of 60 mm.
Applies to all LC20, LCM20, -
/UV, and LCM25 models
Maintenance work
To maintain the QuinsBox, you only need to periodically clean the
white initialization plate
, depending on dust deposition
experience, once a year),
with a dry dust rag
streaks on the surface!
To do this, remove the drawer from the box
and slowly squeeze the scan carriage with your hand to the left so
that you can comfortably reach the initialization plate by hand and
remove the dust with the rag.
(It also makes sense to
free the drawer of lost parts, simply remove,
turn, and shake it out)
The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An
additional calibration does not take plac
of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit.
Applies to all models!
Quins System LCM20 / LCM20UV
Connections
All LCM models have only a power and network connection and a WLAN
antenna.
Fuse
There is a fuse slot between
the power connector and the central power
switch:
- 1,6 A, 250 V, T
Rollers with brakes
To make sure the device does not roll away,
please always use the brakes on the front wheels
Control elements
(see page 8)
page - 10 -
or a focus of 100% (optimum sharpness), the
support is provided on the two angle strips with a clearance height of
with a reduced focus at the bottom PCB level of th
e
assembly (unsuitable for SMD component testing) is the support on
the lower lugs of the side stops and the magnetic
-foot stopper. This
level is intended for assemblies with high THT components with a
/UV, and LCM25 models
.
To maintain the QuinsBox, you only need to periodically clean the
, depending on dust deposition
, (According to
with a dry dust rag
. Do not create any
To do this, remove the drawer from the box
and slowly squeeze the scan carriage with your hand to the left so
that you can comfortably reach the initialization plate by hand and
free the drawer of lost parts, simply remove,
The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An
additional calibration does not take plac
e. Too low illumination causes an initialization error and the box goes out
of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit.
Quins System LCM20 / LCM20UV
All LCM models have only a power and network connection and a WLAN
the power connector and the central power
To make sure the device does not roll away,
please always use the brakes on the front wheels
.
The white balance is firmware controlled, is fully automatic before each scan and can never be changed! This
ensures that a color change of the image recordings, despite possibly weaker lighting is not possible. An
e. Too low illumination causes an initialization error and the box goes out
of order (red LED). In this case, it is only possible to continue working after replacing the lighting unit.

Release: 06 / 2019
Quins
computer
Depending on the
delivery date, the Quins calculator is always a current model of an external supplier (since 2007
DELL). Please observe the operating instructions of the respective manufacturer
This applies analogously to the monitor, keyboard and mouse that are
Also, the conditions of the currently installed Windows operating system and its setup must be considered in
accordance with the software manual
QuinsBox LC25
Connections
(see page 8)
Control elements
(see page 8)
Transport safety
(see page 8)
Drawer
The drawer is the only component that differs from the LC20 or LCM20
The LC20 / LCM20 models are designed to test mounted assemblies or
other high modules, the LC25 and LCM25 models for bare PCBs or
other flat modules.
The variant * 25 differs in the form of the drawer.
The "Tableau drawer" is ideal for circuit boards, foils and other flat
materials.
To attach the modules (circuit boards), a magnetic stop angle and two
magnetic stop strips are used as standard equipment
The possible scan area is marked on the tableau with blue lines. You
can’t scan an image outside of the lines
Further access
ories can be found on our website
in menu
Products / Hardware / Accessories
Maintenance work
(see page 10)
page - 11 -
computer
delivery date, the Quins calculator is always a current model of an external supplier (since 2007
DELL). Please observe the operating instructions of the respective manufacturer
.
This applies analogously to the monitor, keyboard and mouse that are
included in the system
Also, the conditions of the currently installed Windows operating system and its setup must be considered in
accordance with the software manual
.
QuinsBox LC25
-
Quins System LCM25
The drawer is the only component that differs from the LC20 or LCM20
.
The LC20 / LCM20 models are designed to test mounted assemblies or
other high modules, the LC25 and LCM25 models for bare PCBs or
The variant * 25 differs in the form of the drawer.
The "Tableau drawer" is ideal for circuit boards, foils and other flat
To attach the modules (circuit boards), a magnetic stop angle and two
magnetic stop strips are used as standard equipment
.
The possible scan area is marked on the tableau with blue lines. You
can’t scan an image outside of the lines
!
ories can be found on our website
www.quins.de
Products / Hardware / Accessories
.
delivery date, the Quins calculator is always a current model of an external supplier (since 2007
included in the system
.
Also, the conditions of the currently installed Windows operating system and its setup must be considered in
Quins System LCM25

Release: 06 / 2019
Decleration of Conformity
Quins
Image capture unit
Image capture unit
Conforms to the
requirements of the Council Directives on the approximation of the laws of the Member
machines (98/37 / EEC, Electromagnetic Compatibility Directive (89/336 / EEC) and concerning electrical
resources (73/23 / EEC) each on the last version prior
Part of this declaration, the provisions mentioned in each case / standards / specifications:
Brunnenthal, the 03.April 2016
Klaus Kornhaas
page - 12 -
Decleration of Conformity
The following described product::
Quins easy
and
Quins
professional
consist off:
Image capture unit
„Quins LC20, LC25, LC20/UV“
Image capture unit
„Quins LCM20, LCM25, LCM20/UV“
Inspection software „Quins easy“
of the company
Quins
owner. Klaus Kornhaas
Wohnpark 1
D-95189 Brunnenthal
requirements of the Council Directives on the approximation of the laws of the Member
machines (98/37 / EEC, Electromagnetic Compatibility Directive (89/336 / EEC) and concerning electrical
resources (73/23 / EEC) each on the last version prior
agreement.
Part of this declaration, the provisions mentioned in each case / standards / specifications:
EN 60950
EN 55022 Klasse B
EN 55024
EN 61000-3-2
EN 61000-3-3
requirements of the Council Directives on the approximation of the laws of the Member
-states for
machines (98/37 / EEC, Electromagnetic Compatibility Directive (89/336 / EEC) and concerning electrical
Part of this declaration, the provisions mentioned in each case / standards / specifications:

Release: 06 / 2019
Technical data of the Quins
Measurement (W x D x H)
Weight
Camera
Max. Resolution
Effektive Pixel
Max. image size
Scan rate
LC20(/UV) max. assembly size
LC25 max. PCB size
LC20(/UV) passage height
LC25 passage height
Illumination
Light intensity
Interface
Input
Quins computer for all systems
Computer
LCD-Monitor
Mouse/Keyboard
OS
24 months Warranty for all Quins hardware
release: 04 / 2019
Special mechanical designs such as "Big", "Long" or "High" are only mechanically modified to accommodate
the modules. The technical data for power and
page - 13 -
Technical data of the Quins
hardware
LC-Series 693 x 504 x 323
LCM-Series
830 x 510 x 1950 mm (with monitor + 370 mm)
LC-Series 30 kg, LCM-Series 55 kg
CCD line camera (7.020 pixel/line)
1.200 dpi
286,4 Megapixel (= 0,021… mm/dot)
432 x 310 mm
3,8 ms/line (colour)
1,3 ms/line (black/white)
490 x 390 mm (space in the drawer)
600 x 390 mm (space in the drawer)
SMD level 50 mm - 65 mm distance down
THT level 60 mm - 55 mm distance down
10 mm
double row LED illumination
with 308 LED‘s, respectively 308 additional UV-
LED’s
1.600 candela at 50 mm distance
USB 2.0
80 W (during scanning)
PC in optimized equipment
3,5 GHz, 8 GB RAM, 500 GB SSD,
24“ Touch-Screen or TFT (
optionally also 32 "or 42" possible
wireless units
Windows 10, 64bit professional
24 months Warranty for all Quins hardware
Special mechanical designs such as "Big", "Long" or "High" are only mechanically modified to accommodate
the modules. The technical data for power and
scan area remain unchanged and cannot be changed.
830 x 510 x 1950 mm (with monitor + 370 mm)
LED’s
with 400 nm
optionally also 32 "or 42" possible
)
Special mechanical designs such as "Big", "Long" or "High" are only mechanically modified to accommodate
scan area remain unchanged and cannot be changed.

Release: 06 / 2019
Tel.: ++49 (0) 92 81 / 6 43 45
Fax: ++49 (0) 92 81 / 6 26 35
page - 14 -
Klaus Kornhaas
Wohnpark 1
D-95189 Brunnenthal
Germany
Tel.: ++49 (0) 92 81 / 6 43 45
Fax: ++49 (0) 92 81 / 6 26 35
URL : www.quins.de
This manual suits for next models
5
Table of contents