RA MET10PIR-60 User manual

PAGE 2 (TWO - INSIDE DPS)
Meteor Floodlights with PIR
Product Codes: MET10PIR60, MET20PIR60, MET30PIR60 &
MET50PIR60
Box Contents -
1 x Meteor Floodlight with PIR
Dimensions:
MET10PIR-60: L: 158 x W: 120 x D: 54mm
MET20PIR-60: L: 159 x W: 140 x D: 54mm
MET30PIR-60: L: 180 x W: 177 x D: 54mm
MET50PIR-60: L: 215 x W: 223 x D: 54mm
Material: Body - Die-cast Aluminium, Lens - Polycarbonate
Working
Temperature: Standard: -20°C - 45°C
Included:
Integral PIR Sensor
1m Pre-wired Cable
Steel Mounting Bracket
Safety Warning
• The installation should be carried out
by a qualied electrician in compliance
with the current edition of the IEE
Wiring Regulations.
• Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
• Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned o before
installation or any maintenance.
• Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
• Long-term use and voltage uctuations
can reduce the life span of the tting.
• If the tting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
• Follow the provided installation
instructions, using the xings supplied
or recommended.
• Keep out of reach of children.
180-
240V IP65 2
YRS
GUARANTEE
INSTALLATION INSTRUCTIONS
IK07
PAGE 1 (FRONT PAGE)
Specication
10-
50
WATT
LED 6000K
900-
4500LM
Automatic Circuit Breaker Type: B6 B10 B13 B16 B20 C10 C13 C16 C20
Rated Current: 6A 10A 13A 16A 20A 10A 13A 16A 20A
Cable (mm): 1.5 1.5 1.5 1.5 2.5 1.5 1.5 1.5 2.5
MET10PIR-60 150 250 325 400 500 250 325 400 500
MET20PIR-60 75 125 163 200 250 125 163 200 250
MET30PIR-60 60 100 130 160 200 100 130 160 200
MET50PIR-60 30 50 65 80 100 50 65 80 100
Maximum Fittings Per Circuit
1. Ensure there is adequate free air circulation of at least 100mm around the tting. All ttings run hot. It is the installer’s responsibility to consider any re
risk and take appropriate precautions.
2. The nearest illuminated surface must be at least 0.5m from the front of the tting.
3. Check for concealed cables before drilling any xing holes.
4. Fix the bracket to a wall or similar hard surface.
5. Connect the cable to the power supply.
6. NOTE: 10W & 20W Versions are 3 wire connection. To switch on the tting and over-ride the PIR, switch on the mains supply via a local switch, then o and
then on again in rapid succession. To reset the PIR to normal operation, turn the mains supply o via the local switch, then turn on again after 3 seconds.
Installation Instructions
Wmm
Dmm
Lmm

PAGE 2 (TWO - INSIDE DPS)
PAGE 1 (FRONT PAGE)
This Meteor Floodlight with PIR is equipped with a 4th wire (Brown). This wire can be used as follows:
• Connected to a switch (as per diagram below), when switched on will bypass the PIR and the Meteor Floodlight will remain on until switched o.
NOTE: If the 4th (Brown) wire is not required it must be terminated safely as when the PIR is activated it will become live.
Override P.I.R
(Permanently On) Sensor Mode
Must be made safe
as will become live
when PIR is activated
Override Not Required
• Turn the SENS dial anti-clockwise to the maximum point, turn the TIME dial clockwise to the minimum point, turn the LUX dial clockwise to the Sun.
• When you switch on the power, the tting will not illuminate. After a 30 second pre-heat, when the sensor gets the induction signal, the load will turn on.
Once the load switches o, it will then turn on again after 5-15 seconds of the senosr receiving an induction signal.
• After the sensor goes o, trigger the detection eld after 5-10 seconds. The load should work. When there is no induction signals in the sensor, the load
should stop working.
• Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and sensor should not work when testing in daylight. If you
cover the detection window with an opaque object, the load should work. Under no induction signal condition, the load should stop working within 5-15
seconds.
NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX TO THE SUN POSITION, OTHERWISE THE SENSOR WILL NOT WORK!
Testing the PIR
7. Installation Instructions - 4th Wire (ONLY applies to 30W & 50W
The Sensitivity is Poor:
• Please check if there are any objects in the detection eld.
• Please check if the ambient temperature is too high.
• Please check if the installation height corresponds to the height shown in the instructions.
• Please check that your direction of travel doesn’t create poor sensitivity of the Sensor. (i.e. If you are walking towards the tting this creates poor
sensitivity).
The Sensor Can Not Shut O the Load Automatically:
• Please check if there are any possibilities of false triggering.
• Please check if the time delay is at it’s maximum.
• Please check if the power corresponds to the instructions.
• Please check if the temperature near the sensor changes, such as if there’s air conditioning or central heating.
Troubleshooting

T: 0800 195 0006
sales@redarrowelectrical.co.uk
Red Arrow Electrical Distribution
Cortonwood Drive, Brampton,
Barnsley, S73 0UF
redarrowelectrical.co.uk
INS/OUTDOOR/0006/METPIR/V2
• This tting will require routine cleaning if used in adverse (dust, paint, welding, oils etc) environments. Do not use solvents, aggressive detergents or
abrasives.
• The light source & driver in this luminaire are not replaceable. When the tting comes to the end of it’s life or you choose to replace it, please do not dis-
pose of it with your normal waste. Please recycle where the facilities exist, check with your local authority for suitable options.
Maintenance
This product is guaranteed for a period of 2 years from the date of purchase. The guarantee is invalid in the case of improper use, tampering, removal of the Q.C.
date label, installation in an improper working environment or installation not according to the current edition of the I.E.E. Wiring Regulations (BS7671). The
guarantee is also invalidated if the luminaire has been insulation tested. Should this product fail during the guarantee period it will be replaced free of charge,
subject to correct installation and return of the faulty unit. We do not accept responsibility for any installation costs associated with the replacement of this
product. Your statutory rights are not aected. We reserve the right to alter specications without prior notice.
Guarantee
This manual suits for next models
3
Table of contents
Other RA Floodlight manuals
Popular Floodlight manuals by other brands

Leviton
Leviton RS Series installation instructions

Venture Lighting
Venture Lighting AV0004-A user manual

Golight
Golight Stryker Instruction guide

Briteq
Briteq COB SLIM 100-RGB Operation manual

WE-EF
WE-EF FLC200 LED Series Installation and maintenance instructions

EuroLite
EuroLite LED FX-400 DMX Flower Effect user manual