PAGE 2 (TWO - INSIDE DPS)
Meteor Floodlights with PIR
Product Codes: MET10PIR60, MET20PIR60, MET30PIR60 &
MET50PIR60
Box Contents -
1 x Meteor Floodlight with PIR
Dimensions:
MET10PIR-60: L: 158 x W: 120 x D: 54mm
MET20PIR-60: L: 159 x W: 140 x D: 54mm
MET30PIR-60: L: 180 x W: 177 x D: 54mm
MET50PIR-60: L: 215 x W: 223 x D: 54mm
Material: Body - Die-cast Aluminium, Lens - Polycarbonate
Working
Temperature: Standard: -20°C - 45°C
Included:
Integral PIR Sensor
1m Pre-wired Cable
Steel Mounting Bracket
Safety Warning
• The installation should be carried out
by a qualied electrician in compliance
with the current edition of the IEE
Wiring Regulations.
• Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
• Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned o before
installation or any maintenance.
• Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
• Long-term use and voltage uctuations
can reduce the life span of the tting.
• If the tting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
• Follow the provided installation
instructions, using the xings supplied
or recommended.
• Keep out of reach of children.
180-
240V IP65 2
YRS
GUARANTEE
INSTALLATION INSTRUCTIONS
IK07
Specication
10-
50
WATT
LED 6000K
900-
4500LM
Automatic Circuit Breaker Type: B6 B10 B13 B16 B20 C10 C13 C16 C20
Rated Current: 6A 10A 13A 16A 20A 10A 13A 16A 20A
Cable (mm): 1.5 1.5 1.5 1.5 2.5 1.5 1.5 1.5 2.5
MET10PIR-60 150 250 325 400 500 250 325 400 500
MET20PIR-60 75 125 163 200 250 125 163 200 250
MET30PIR-60 60 100 130 160 200 100 130 160 200
MET50PIR-60 30 50 65 80 100 50 65 80 100
Maximum Fittings Per Circuit
1. Ensure there is adequate free air circulation of at least 100mm around the tting. All ttings run hot. It is the installer’s responsibility to consider any re
risk and take appropriate precautions.
2. The nearest illuminated surface must be at least 0.5m from the front of the tting.
3. Check for concealed cables before drilling any xing holes.
4. Fix the bracket to a wall or similar hard surface.
5. Connect the cable to the power supply.
6. NOTE: 10W & 20W Versions are 3 wire connection. To switch on the tting and over-ride the PIR, switch on the mains supply via a local switch, then o and
then on again in rapid succession. To reset the PIR to normal operation, turn the mains supply o via the local switch, then turn on again after 3 seconds.
Installation Instructions