Raycan RadTarge-Mini User manual

User Manual
RadTarge-Mini
Pioneer of All-Digital Positron Emission Tomography & Radiation Detection

II Product Features
Lifetime Personal
Dosage Management
Built-In Memory
Data Never Lost
High Sensitivity
Fast Response
RadTarge-Mini is a compact, robust and high performance radiation detection system. It interfaces via
Bluetooth to mobile devices such as phones and tablets running the RadMay mobile App. Together
RadTarge-Mini and RadMay offer a high performance, versatile and low cost radiation detection and
dosimetry solution which addresses a very wide range of applications and use cases.
RadTarge-Mini detects ionizing radiation by means of a scintillator and a high performance photo
detector. The readout of the photo detector signals is realized through our patented MVT or Multi
Voltage Threshold technique. This puts RadTarge-Mini performance in a class of its own. Its detection
sensitivity is up to 20 times higher than that of traditional Geiger-Müller or film based systems. A low
energy threshold of 20 keV helps reliably detect radiation sources commonly encountered in industry
and medical imaging. A maximum count rate of 2 million counts/second serves to cover worst case
scenarios in high radiation environments.
The RadMay mobile App and cloud service is a flexible and intuitive tool to view, save and manage
dose and dosimetric data received from RadTarge-Mini. The user can configure alarm thresholds,
accumulate dosimetric data, map and visualize the radiation environment using GPS geo-location. All
data is safely stored to the RAYCloud which offers a wide range of review and analysis functions.
Time, Dose, Location.
Three-in-one
Measurement
I Product introduction
Compact
Delicate Appearance
Bluetooth 4.0 Wireless
Communication
Cloud-Based
Data Storage
Global Dose Distribution
and Movement Track Log

III Product Display
2.Product Diagram
13.86
μSv/h
+
SN: 000XXX FCC ID:2AC7P-113
RadTarge-Mini
①------Company Logo
②------Display Screen
③------Operation Button
④------Detector Location Mark
⑤------RadTarge-mini Product Name (RadTarge-Mini)
⑥------Product Serial Number
⑦------FCC & CE Certification
⑧------MicroUSB Port
①------RadTarge-Mini
③------Data Cable
②------User Manual Mini Card
1
1
2
3
2
4
5
6
78
3
1.Package Diagram

3.Mini Card Diagram
Service Hotline:(86) 512-6239-1918
www.ray-can.com
APP IOS APP Android User Manual
RadTarge-Mini
iOS RadMay Download Code
Android RadMay Download Code
User Manual Download Code
123
1
2
3
RadTarge-Mini App RadMay
Scan to download
Note:
Visit http://ray-can.com/contact to download. Scan the user manual QR code to
enter the user manual website.

1.1 Powering On
Press the operation button for 4 seconds until the screen lights up,accompanied by a beep and
vibration. Automatically enters the main interface/dose equivalent rate interface 3 seconds after the
machine starts.
0.16
μSv/h
IV Operation Manual
0.16
Dose μSv
Dose pageDose rate page
0.05
μSv/h
Dose pageDose rate page
1.2 Switch Interface
Press the operation button to switch between Dose Equivalent Rate Interface and Cumulative
Dose Interface.
1.Device Operation Instructions

0.86
μSv/h
0.86
μSv/h
0.86
μSv/h
0.86
μSv/h
Bluetooth disconnected Bluetooth connected
Charge in turn on mode
Bluetooth error
1.3 Powering Off
Press the operation button for 2 seconds to power off the device. The device will vibrate when it is
successfully turned off.
1.5 Charging and Battery
Device enters charging mode when a MicroUSB cable is connected.
When powered on, upper right screen will display a charging animation. When
the battery is full, the charging animation stops.
1.4 Bluetooth
When the device is connected to RadMay via Bluetooth, the Bluetooth icon will appear at the upper
left of the display. Please refer to the RadMay operation manual for connection instructions. An
exclamation mark (!) signifies Bluetooth connection problems; please contact the manufacturer for
help.

Charge in turn off mode
Low battery
When powered off, a battery icon is displayed in the middle of the screen with a charging animation.
When the battery is full, the charging animation stops.
When the device is not charged, the battery icon shows the remaining battery life.
When the device is low battery, it will notice users to charge and then turn off.
Full
Partially charged
Battery low
No battery, please charge
Warning
Low Battery
Shutting Down...

overload
过载界面
Default settings Format Restart
1.6 Reset
Users can reset the device via RadMay. After clicking the reset key, the device will take
three actions: restore settings, format file system and restart. After restarting, all settings
and data will be restored to default settings.
Initializing
Restoring Settings...
Initializing
Formatting File Sys..
Initializing
Shutting Down...
1.7 Overload
When the dose rate passes the dose rate measurement range, the device will enter overload mode,
and the screen will display "overload". When the dose rate is back in range, the device will recover
in 5 seconds.

Detector
Type of Radiation Detected
Energy Range
Dose Rate Range
Integrated Dose Range
Sensitivity
Energy Response
Dose Rate Linearity
Accuracy
Alarm Threshold
Alert Options
Alarm Response Time
Overload Display
Communications
Ergonomics
Power Supply
Battery Life
Display
Dimensions
Weight
Accessories
Initialization Time
Bluetooth
Front facing tilted screen
Rechargeable lithium-ion battery
Typically 120 h in background field
OLED
2.4 x 1.8 x 0.8 in (60 x 46 x 20 mm)
2.1 oz (60 g)
MicroUSB cable
< 2 s
Operating Temperature
Storage/Transport Temperature
Relative Humidity
IP Rating
32–122 °F (0–50 °C)
-4–158 °F (-20–70 °C)
≤ 90% (non-condensing)
TBD
2. Specifications
Radiological
Electrical and Mechanical
Environmental
Certification
EMI/EMC Compliance
FCC
CE
FCC ID
Exceeds IEC 61526 requirements
FCC certification
CE certification
2AC7P-113
YSO(Ce) scintillator + SiPM
Gamma; X-ray
30 keV–3 MeV
1 µrem/h–10rem/h (0.01 µSv/h–100mSv/h)
1 µrem–999 rem (0.01 µSv–9.99 Sv)
110 cps/mrem/h (11 cps/µSv/h) (∝ Cs-137)
≤ ±30% (∝ Cs-137) @ 30 keV–1.5 MeV
≤ 20% up to 10 rem/h (100 mSv/h)
±20% (∝ Cs-137)
User-set values for dose rate: 100 µrem/h–10 rem/h (1 µSv/h–100mSv/h)
Audible (80 dB at 12 in / 30 cm)、Visual (LED and display)、Vibrating
< 8 s
Activation when > 5 rem/h (50 mSv/h)

3.1 Detector and Radiation
RadTarge-Mini uses a YSO scintillation crystal coupled with SiPM as the detector to
measure gamma and X-rays. It can measure dose equivalent rate and cumulative dose.
3.2 Dose Display
The device can display real-time dose equivalent rate and cumulative dose. Users can
switch the units between international standard units and traditional units through the RadMay app.
3.3 Gamma and X-Ray Detection Features.
Energy Response Curve
3. Radiation Detection Features

Angular Response
Angular Response

Ⅴ RadMay Application
3.4 Alarm Modes
According to the American National Standard for Dosimetry, ANSI HPS N13.11 Personnel
Dosimetry Performance - Criteria for Testing, the device should have at least one alarm mode on.
RadTarge-Mini supports three alarm modes: audible, vibrating, and audible & vibrating. Users can
set the alarm mode via RadMay. The alarm response time is less than 8 seconds when the
radiation level passes 10 μSv/h from the background radiation level. Users can set the alarm
threshold within the measurement ranges:
· 1μSv/h Real-time dose rate pre-alarm threshold, suggested value: 1 μSv/h
· 10μSv/h Real-time dose rate alarm threshold, suggested value: 10 μSv/h
· 1mSv Cumulative pre-alarm threshold, suggested value: 1 mSv
· 10mSv Cumulative alarm threshold, suggested value: 10 mSv
· Pre-alarm frequency is 1 time/second, alarm frequency is 2 times/second.
3.5 Data Transfer and Storage
Data Transfer: Built-in Bluetooth 4.0 module transfers data to RadMay to manage dosage data.
Data Storage: Built-in flash storage can store cumulative dose for 1 year and real-time dose alarm
events for 1 month.
RadMay is a mobile app designed to manage dosage data from RadTarge-Mini. Additionally, using
data from the smartphone's GPS, RadMay can establish the global radiation distribution and
personal lifetime dosage log by recording, summarizing and analyzing radiation data.

1. RadMay Structure
Measure Explore Global Setting
Register & Log in
Radiation path
The dose distribution
Monster
Dr.MAY
Superman
User management
Device settings
APP settings
Add Device
Integration
Real-time dose
Cumulative dose
Map display
Alarm reporting
Historical curve
Threshold setting
Alarm reporting
Historical curve
Threshold setting
Historical track
Recording Settings
Recording

Real-Time Dosage (Dose Equivalent Rate):
Represents the health effects of ionizing radiation on the human body per unit of time. In the SI
system of units, the unit of measure is μSv/h or mSv/h. 1 Sv/h = 1000 mSv/h,1 mSv/h = 10 00 μ
Sv/h
Cumulative Dose:
1000μSv;Represents the health effects of ionizing radiation on the human body over a period of
time. In the Si system of units, the unit of measure is μSv or mSv.
Lifetime Cumulative Dose:
Lifetime cumulative dose is the cumulative dose since the user registered his or her account.
Periodic Cumulative Dose:
The cumulative dose from the time point defined by the user to now. Users can compare this value
to standard annual cumulative dose.
Custom Periodic Dose:
The cumulative dose between the start and stop time points defined by the user.
Open RadMay. The login/registration screen will automatically appear. RadMay will ask permission
to access location data; press "allow" so RadMay can provide time, location and dosage data.
3. Registration
2. Term Definition

Click "Register" to enter the registration page and fill out the form. Press
"Click to get verification code" to retrieve and enter the verification code to finish registration.
Enter the verification code sent to your e-mail to complete registering.
Click "Forgot password" to reset password.
4. Log in

After login, click the "Profile" to edit your profile.
Click ">" to enter the Personal Info page, and click edit to modify personal information.
5. Edit Profile

In the Personal Info page, users can edit their nickname, gender, and password. Press“X”to cancel or
“√”to save changes and return to the Profile page.
RadMay can help users manage their lifetime dosage. One account is tied to one RadTarge-Mini.
New users need to pair their device to start their radiation detection journey. If the user needs to
change his or her device, unpair the old device before pairing a new device. The data for the old
device is still stored in the old account. Turn on Bluetooth, enter the Profile page, click "Add
Device," place the device near the phone, and choose the device. The name for the device should
be RadTargeMini SN: XXXXXX. XXXXXX is the six-digit serial number on the back of the device.
Once the device is connected successfully, the message "Connected successfully" will appaer.
RadMay will connect to this device automatically when logging in next time.
6. Device Connection


In the Profile page, click "App Settings" to enter the app settings page. Functions include "Alert
settings," "Language," "Display units," "Back up data," "Recover data," "Version," "About RadMay,"
and "Contact us."
"Alert settings" include "Dose rate pre-alarm," "Dose rate alarm,""Cumulative dose pre-alarm," and
"Cumulative dose alarm." "Alarm modes" include Audible, Vibrating,and Audible & Vibrating."Dose
rate alarm,""Cumulative dose pre-alarm," and "Cumulative dose alarm." "Alarm modes" include
Audible, Vibrating, and Audible & Vibrating.
Language: English, Chinese
Display unit: Sv, rem;
Back up data: Back up data to server
Recover data: Recover data from server
Version: Check RadMay version
About RadMay: Brief introduction to RadMay
Contact us: Manufacturer contact information
7. App Settings

Click device name on "Profile" to enter "Device Settings" page.
[Link device]: When on, RadMay will automatically link the device to transfer data.
[Energy saver]: When on, the device display will turn off after 10 seconds of inactivity.
Recommended function.
[Sync data]: When on, will automatically sync device data to local storage
[Alert settings]: Change the alarm modes of RadTarge-Mini.
[Clear dose]: Reset lifetime cumulative dose to 0. This operation will not clear device data history;
please use carefully.
[Unpair device]: Unpair device from app.
[Sync time]: Sync the device time with phone time, GMT.
[Update firmware]: Update RadTarge-Mini firmware.
[Default settings]: Reset settings to default.
Measurement is the basic
function module of RadMay. It can display and process RadTarge-Mini's dose rate and cumulative
dose simultaneously.
8. Device Settings
9. Measurement
Table of contents
Popular Measuring Instrument manuals by other brands

Sekonic
Sekonic SPECTROMASTER C-800 operating manual

REED
REED R8150 instruction manual

Ingeteam
Ingeteam INGECON SUN 3Play quick start guide

M-system
M-system R7CWTU instruction manual

Greenheck
Greenheck Sure-Aire 386719 Installation, operation and maintenance manual

Eaton
Eaton Powerware Environmental Rack Monitor user guide