Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
ATTENTION
This user guide contains important info concerning
usage, safety and installation.
This user guide shall be transferred to any new user.
The technical data has to be considered indicative
and can be changed any time by the producer
without notification.
This air sanitizer uses its own metal body for heat
dissipation. A proper working temperature ensures
maximum efficiency along its lifetime.
Environmental Temperature
+0 to +30°C
RECCOMENDATIONS:
●
do not cover the product when activated: it might
block the airflow rendering its action ineffective
●
do not expose the device under direct Sun light: it
might increase its temperature reducing its lifetime
●
do not use the device in proximity of heat sources if
> 30°C: it might increase its temperature reducing its
lifetime

3
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
GENERAL INDICATIONS
1. This device is meant for its intended use: air
sanitization for indoor environments. The
producer is not responsible for any damage
cause by improper use.
2. Once unboxed, keep the device and packaging
away from children.
3. The special grilles positioned on both sides of
the device -figure 1- are made of a special
material: avoid any hit and rub to preserve
them
figure 1: Honeycomb grille present on both ends of ray
4. Do not plug or activate the device if wet or on
a wet surface: the device uses extremely low
voltage and there is no risk for electrocution
yet it might get damaged.
5. In case of damages of the power cord, get in
touch with the local distributor or producer for
assistance.
6. Keep the external power supply and power
cords dry and away from heat sources.
7. Do not use the device outdoor.

4
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
8. Make sure the device has enough space from
both its ends to allow a proper airflow ensuring
its efficacy.
9. Do not cover the device when running.
10. Any attempt to open and sabotage the device will
nullify any responsibility of the producer and void
the warranty.
11. Do not touch the device with wet hands.
12. Do not allow children to use the device without
supervision.
OPERATION
Place ray on a stable surface with both ends free to
allow air intake and release.
To activate the device, as shown in -figure 2-:
1. plug the round connector to the inlet of the
device
2. plug the external power supply to the wall
socket
3. switch the rocker switch in position “I”
4. to switch of the device, switch the rocker in
position “0”.
Using and wall mount timer, not included, it is possible
to automatically run the device accordingly to the
timer’s options: total running time or by schedule.

5
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
figure 2: Rocker switch and power plug
USE TIPS
It is suggested to keep the device running during the
whole duration of the room occupancy.
The device can be activated before, during and after
the occupancy of the room.
It is suggested to keep the device running after the
room occupancy, accordingly to -table 1-, in order to
ensure significative air sanification before the next
occupancy.
Room Volume
m^3-
ft^3
Room Surface
m^2 –
ft^2
Run-time
minutes
40 -
1400
16 -
170
30
80 -
2800
33 -
355
80
120 -
4200
50 -
540
120
160 -
5600
67 -
720
180
table1: Indicative run times after room occupancy

6
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
ATTENTION
In order to ensure the best performances of ray, it is
suggested to perform a check-up of the device after 2
years or 15’000 hours of functioning. Contact the local
distributor or producer.
CLEANING AND MAINTENANCE
Unplug the device before any cleaning operation.
To clean the external surface of the device, use a soft cloth,
non-abrasive, either dry or damp with water or glass
cleaning products.
Do not use any spray or liquid in proximity of the grilles on
both ends or the power switch and power connector.
Do not submerge in liquids.
Do not use any corrosive products or solvents.
In case of dust presence on either grille, it is possible to:
•wipe with care and without using pressure with a
dust catcher cloth
•blow with compressed air duster paying attention to
not damage the grille

7
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
BOX CONTENT
1x
ray
1x
24V Power supplier
2x
support bracket A
2x
support bracket B
8x
screws M4
table2: Box content

8
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
WALL AND CEILING INSTALLATION
Wall and Ceiling installation shall be performed by
professionals.
Make sure the wall or ceiling is solid enough to support the
mounting of the device.
Ray can be mounted on walls or ceilings using the provided
brackets.
The
- support brackets A
- must be fitted on ray using the
provided -
screws M4
–as indicated in -figure 2- achieving
the result in -figure 3-.
figure 2: threaded holes for -
support brackets A
-

9
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
figure 3: -support brackets A- fitted on ray
The -
support brackets B
- must be fitted on the designated
wall/ceiling using wall plugs suited for the specific surface.
The -
support brackets B
- must be fitted parallel at a
distance of 530mm as shown in figure 4.
figura 4: -staffe supporto B- tassellate
Proceed with the alignment of -support brackets A- with the
relative -support brackets B- and lock them using the
provided -
screws M4
- as shown in figure 5.

10
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
figure 5: -
screws M4
- locking -
support brackets A
- and -
support brackets
B
-
In case of wall mounting in a vertical position, it is
suggested to place the inlet grille on top and the outlet
grille (where the status LED is visible) at the bottom, as in
figure 6. This will allow to optimize the efficiency exploiting
the natural air movement.
The status LED is placed inside the outlet grille.
figure 6: vertical wall mount
Top –Inlet grille
Bottom –Outlet grille

11
Info-it@ray-uvc.it ray-uvc.com Rev.2b
USE AND MAINTENANCE
TECHNICAL DATA
DISPOSAL
The user is responsible for the proper disposal of the
device, in accordance with the local legislation.
Voltage
24V
Power
23W
Working Temp Range
0°C ⟺+30°C 32°F⟺86°F
Volume Air Sanitized
80m^3/h –47cfm
Weight
3.5Kg –7.7lbs