(2) Mechanical installation
• Mountunitonappropriatesupportspigotofsize34-42mmDiameter
• Secure unit on spigot with supplied grub screws. Ensure spigot is fully engaged and tighten
grubscrewstotorque17Nm(5mmhex)
• For Outdoor applications the supply cable should be suitably protected from the environment
e.g. inside conduit or a lighting column
WARNING:
Ifthefactoryttedcableisdamageditmustbereplacedbyasuitablyqualiedpersonto
avoida hazard.The lightsource containedin thisluminaire shallonly bereplaced bythe
manufacturer or a nominated representative.
Functionality
TheunitrespondswhenpowerissuppliedtotheinternalLEDdriver.IftheunithasaPhotocell
ttedthisactsasanon/offswitchforthepowerreachingtheinternalLEDDriver.(For Photocell
On/Off Lux Levels please see the specication table)
Driver Programs (these will be marked on the driver)
The unit will function according to one of the following factory-set programs;
ID1 - Soft Start: 100%outputfordurationofnight(5secondsoftstart).
ID2 - Timer Dimming: 100%power(5secondsoftstart)for5hoursfrompowerup,
then50%poweruntilthenextcycle.
*ID3 - Active Dimming 50%
*ID4 - Active Dimming 25%: 100%output(5secondsoftstart)frompowerup,thendimsto
either50%(ID3)or25%(ID4)power,aroundthemidpointof
thenightanduptoamaximumof6hoursafter,thenbackto
100%ifit’sstilldark.
Thisprogramwouldtypicallyrequiretheuseofaninbuiltor
remotephotocelltomonitorthehoursofdarkness.
ID5 - Event Trigger: Theluminairewilloperateat100%for30minutesandthen
switch off until re-activated
Custom: Acustomerspecicprogram.
* Notsuitableforlocationswherethelengthofnightis23hoursorgreater.Fortherst3nightsthe
luminaireisonat100%powerfromsunsettosunrisewhilstthesystemlearnsthelengthofnights.
Unitdoesnotcompensateforvariationswithinlocaltimezones.Unitdoesnotcompensatefor
internationalclockchanges.