RealSYS SmartCopier User manual

1
SmartCopier
(Parameter Read /Write Function)
User Manual
RealSYS
V2.21

2
iNOTE
•The specifications and contents of this product are subject to change for
performance improvement.
•Prohibit replication without permission, change, and the use in other applications
of software and related documentations.
•Free A/S is possible within the warranty period and if the failure is due to
carelessness of user handling, the repair costs may be paid by user.
•The person who actually use the products is responsible for damage, if it is
caused by the user’s carelessness or the safety precautions are not taken into
account.
•Except what is described in this book,
•When the product is damaged due to the improper use or approaches which is
not described in this manual, repair requests can be rejected.
SMART COPIER

3
•OPERATING PRECAUTIONS
•Use provided insulated DC 5V, above 2A product for external adapter.
•Use four reliable AA-type batteries for internal power source.
(Since the power consumption by inverter model is different,
it is recommended to use a lithium-ion battery.)
◈Power Supply
◈SD Card and USB
•When inserting or removing SD card, check that the product is in non-
operating state or the power is turned off in advance.
(SD card supports up to SDHC 64GB, but this takes a long time to initialize,
so it is recommended that no more than 8GB.)
•Do not turn off the power or separate the cable from the device before the
USB is disconnected in the user PC application program or PC is turned off
during USB communication.
◈Firmware Download
•Do not turn off the power during functional operations before success or
failure screen is displayed.
•Do not remove the SD card from the device during functional operations.
•Do not apply power to an inverter during functional operations.
•Do not disconnect the down load gender or cable during functional operations.
◈Parameter Read/Write
•Do not connect/disconnect RJ-45 cable terminal during functional operations.
•Do not remove the SD card from the device during functional operations.
◈Inverter Connector and Gender
•Be careful not to pinch the conductive material in the gap of the connector
terminal or gender.
•Be careful with the direction of polarity when connecting the gender to the
inverter.
!
SMART COPIER

4
Contents
1. Specifications …… 5
2. Exterior …… 6
3. Monitor Functions …… 8
4. Input Devices …… 11
5. Operation and Use Description …… 14
6. Smart Copier Firmware Update …… 21
SMART COPIER

5
Item Description Note
Product •SmartCopier Firmware/Parameter combined
•SmartCopier Parameter only
Display •Black and white graphic LCD 128 x 64 (green backlight
available)
•Power / Error / Read / Write State LED
Input Device •Main body power ON / OFF switch
•Up / Down / Mode / Enter / Shift button key
•USB 2.0 Communication Terminal
Output Device •RJ45 Communication Terminal ( for Parameter Comm. )
•Connector / Flat 10P Cable (for Gender Firmware Download
Memory Card •SD Card SDHC (Up to 64GB, recommend 8GB)
•FAT32
Power
Standard
•Battery for internal power (four general AA-type batteries)
(In the case of providing the battery, and enables
Parameter features more than 500 times)
Adapter for external power (insulated DC 5V, above 2A)
Refer
to
16page
Software •Support window file conversion and management program
•Support window device driver
•Windows XP, Windows Vista, Windows 7, 8,10 compatible.
Main Function •Firmware Download / Parameter Read / Parameter Write
•Target power supply
•USB insulation function
Supporting
Model & CPU
Type
•S100 / H100 / iS7 Inverter Model
•Freescale Coldfire MCF51JM32
•Freescale Coldfire MCF51JM128
•TI-DSP TMS320F2809
•TI-DSP TMS320F2811
Size & Weight •70 x 190 x 30 ( Width x Length x Height )
•Weight 250g ( except battery weight )
mm
Package •Main Body 1Set / User Manual / Software CD / USB2.0
Cable / SD Card 8GB / DC Power Adapter (절연형) /
AA Lithium-ion Battery Set / RJ-45 Cable
Certification •MIC Certification KOREA
1. Specifications
SMART COPIER

6
2. Exterior
2.1 Front
LCD Display
2.1 Side
Power Switch
SMART COPIER
State LED
Key Button
<Left Side> <Right Side>
USB Terminal
External Power
Input Terminal
SD Card Slot
Battery Cover

7
2.2 Top
Firmware
Download Terminal
Parameter
Communication
Terminal ( RJ-45 )
2.3 Back
Battery Case
( AA-Size x4 )
SMART COPIER
Battery Cover

8
3. Monitor Functions
Status bar
Contents display
Cursor display
3.1 LCD Monitor Display
- Type of state Icon
/ /
: Firmware Download Mode Display
: Parameter Read/Write Mode Display
: Inverter Model Display
: Parameter Write Mode Display
: Parameter Read Mode Display
: BDM Write Mode Display
: Real DSP-UT Write Mode Display
/ : Battery Status Display
: USB Connection Status Display
: SD Card Insertion Status Display
SMART COPIER

9
- Information message type
This screen is displayed when SD Card is empty in
the SD Card slot terminal of the product. If you
press the Shift key, you can ignore the message.
This screen is displayed in the process of
recognizing the Card when you insert the SD card
to slot terminal. Do not remove the SD Card at this
time.
This screen is displayed when the inverter is
turned on and in the operating state. To continue
the operation, turn off the power of the inverter of
disconnect the connector from the inverter.
This screen is displayed when the application
installed on the user’s PC and the main body of
product are communicating. Until it is
disconnected from the PC program, the user can
not execute any operation.
SMART COPIER

10
①Power Status LED
②Error Status LED
3.2 Display Functions
③Read Status LED
④Write Status LED
LED Color Waveform State Description
Power
Status LED
Green ON Steady power input state
Green Toggle
(1s intervals) Low battery state
Error Status
LED
Red Toggle
(1s intervals) Operation error or failure state
Red Toggle
(1s intervals)
Not under functional operating
condition
Read Status
LED Green Toggle
(1s intervals)
State of reading data from the
target
Write Status
LED Green Toggle
(1s intervals)
State of writing data to the
target
ON continue
ON repeat
ON repeat
ON repeat
ON repeat
ON repeat
- LED Display State
SMART COPIER
① ② ③ ④

11
4. Input Devices
4.1 Button Key
UP key : Move the cursor to up.
DOWN key : Move the cursor to down.
ESC key : Move the screen to its previous state or Cancel Action
ENTER key : Execute the function indicated by cursor / Select item
MODE key : Move to the initial screen or call the special command
SMART COPIER
- Button Description
Move to up
MODE
selection
ENTER
Move to down
ESC selection

12
When the care is inserted, put the card deep into the SD Card slot of the
main body along with the sound “click”. The card must be fixed not come
out of the body.
4.2 SD CARD Insertion / Removal
- When the card is inserted
When the card is removed, put the card deep into the SD Card slot of the
main body once again along with the sound “click”. Then the card will be
separated out of the main body. At this time, pull the card and remove it
from the main body.
- When the card is removed
②
①
SMART COPIER

13
4.3 USB Connection / Disconnection
- Connection
Exit the application provided to user PC, and then remove the cable from
the USB terminal of the main body.
- Disconnection
USB 2.0 Mini-B Cable
USB 2.0 Mini-B Cable
SMART COPIER
Connect the cable to the USB terminal of the main body.
5. Output Port and Gender Structure
RJ-45 Connector Terminal.
(Parameter Read/Write
Connector
10Pin Connector Terminal
(NOT Connection,
Only used Firmware Write)
RJ-45 connected to the inverter connected to the gender use 1:1 direct cable
with the target board.

14
5. Operation and Use Description
5.1 Parameter Write
SMART COPIER
•Enter the [Parameter Write] on the menu screen.
•Select the file using the Up/Down keys on the file List.
Press to the <ENTER>, writing the file.
Press to the <ESC>, return menu previous.
•To make sure that the displayed information is
consistent with the target inverter information.
•If the both information match, press the [Enter] key to
write, if not press the [ESC] key to cancel.
•Writing operation.
(Key operation prohibited until the operation is completed)
•Please check the following failure.
1) Please check cable connection and
battery status.
2) Please check the file is correct.
※ From the following steps, <Enter> and <ESC> key
can only be used.
Press key?
<Enter> key
<ESC> key
•Writing sccess.
•Press to <ENTER>,
Rewrite
•Press to <ESC>, move to
previous menu.

15
•Enter the [Parameter Read] on the menu screen.
•Ready state for read.
•Press the Enter key to read or press the Shift key to
cancel.
Warnning!
Is a randomly generated file name, the user must remember it.
•Reading operation.
(Key operation prohibited until the operation is completed)
•Display result info.
If result success, data file
auto save.
•Press to <ENTER>.
retry reading operation
•Press to <ESC>, Move to
previous Menu,
※ From the following steps, <Enter> and <ESC> key
can only be used.
SMART COPIER
Press key?
Enter key
<ESC> KEY
•Please check the following failure.
1) Please check cable connection and
battery status.
2) Please check Parameter information of
the IO card is correct
If not written in the parameter information of the inverter
in IO cards, the Read operation will fail.
Save the Parameter of the inverter before
the IO Read operations(Refrence 6.4.2 - ②)
3) After check list, retry the <ENTER> key.
5.2 Parameter Read

16
Press key?
•Enter the [Firmware Download] or [Parameter Read]
on the menu screen.
•Guide screen of file deletion is displayed.
•Press to <Enter> key, delete file.
•Press to <ESC> key, save cancel.
•When the file list screen is displayed, Press and hold
the Mode key for 3 seconds.
•Result screen of file deletion
SMART COPIER
※ From the following steps, <Enter> and <ESC> key
can only be used.
Enter key
Shift key
5.3 File remove

1717
5.4.1 iS7 Parameter Read/ Write
SMART COPIER
Turn off the inverter power supply, iS7 the keypad must be separated from the body.
Then, connect the RJ45 cable to smart copier and keypad.
ON the power of Smart Copier, proceed to Read/Write.
If the version of the model code of the inverter or different, is the cause of the
failure.
Down-loading is the same as the existing LCD-type keypad.
◈Connection operation for parameter read/write

5.5.1 Supplemental description of the Parameter read / write - ①
SMART COPIER
◈Connection operation for parameter read/write
OF
F
O
N
NP
N
PN
P
VO
IO
V
I
Turn the inverter OFF, connect the Smart copier and inverter IO card
(S100 or H100) with a RJ45 cable. ( RJ45 specifications: Direct, within 300mm)
Read/Write only while supplies power to the inverter in the Smart copier.
Read on during operation S100,if the inverter displays 'S100-> U' on 7-SEG
,after completion display disappears. (If there is no display of H100 Model)
Write on during operation S100,if the inverter displays 'S100->d' on 7-SEG
,after completion display disappears. (If there is no display of H100 Model)
If the power of the inverter is turned on, Read / write operation is failed, the inverter trip occurs.
18

19
19
5.5.2 Supplemental description of the Parameter read / write - ②
SMART COPIER
◈Read the previous command in the Smart copier, Parameter to
store the inverter
Before perform Parameter read, you should upLoad the parameter of the inverter
in IO CARD. Items related parameter of the inverter is ‘DRV-91’, you can perform
the ‘3: SmartUpLoad’. If after UpLoad is complete, then the power of the inverter
OFF, perform the Read operation of the Copier.
Code related inverter parameter copy.
Code
Com Adr
Desc. Display
LCD Setting Range Init.
Value Property
V/F
SL
DRV
-91 0h115B SmartCopy
SmartCopy
0
None
0X/A
O
O
1
Reserved
2
Reserved
3
SmartUpLoad
•For DRV-91
•0 : None
•1 : reserved
•2 : reserved
•3: SmartUpLoad : If you choose, parameter values are stored in a read memory.
◈Parameter Read /Write description of Smart Copier
Please be sure to power OFF the inverter when Parameter Read / write operation
using the copier.
Parameter Read :
Operation to copy the parameter values of the inverter to the copier.
Please refer to 5.4.3 before performing this function.
(If Parameter values are not stored in the inverter, this function will fail.)
Parameter Write :
Operation to copy the parameter values to the inverter in the copier.
(If the inverter models vary, this behavior is the cause of the failure.)
After completing the operation, the Parameter value will be applied automatically
when the power to the inverter ON.
Operation of the copier, please refer to section 5.1 or 5.2.

20
5.5.3 Supplemental description of the Parameter read / write - ③
SMART COPIER
When parameter write is successfully completed, remove the connector and
turn ON the power to the inverter.
Since, parameter values are automatically saved to the
inverter, the inverter 7-seg W-dL"will be displayed.
Store operation is complete when, in the 7-seg display
disappears.
◈After parameter write, inverter operation.
스마트 카피어
Parameter 1 Grp.
Parameter 2 Grp.
Parameter 3 Grp.
…………
…………
전원 ON 시
자동 동기화
인버터
내부
파라미터
저장
공간
1
(R)
WRITE
자동
WRITE
READ
Upload 저장
공간
2
(W)
◈Parameter read / write progress and structure
Parameter
in
INVERTER
POWER ON INVERTER
AUTO
READ
AREA
WRITE
AREA
POWER OFF INVERTER
INVERTER I/O CARD
SMART COPIER
If the Parameter File Copier and inverter models vary, displayed on the display
window of the inverter as follows.
( In case LCD Loader : “ParaWrite Fail”
In case 7-Seg Loader : “WERR” )
Other manuals for SmartCopier
1
Table of contents
Other RealSYS Copier manuals