Teon tape should be used on all NPT connections (end con-
nections and gauge connections).
NOTE: Great care must be taken not to strip the NPT end
connections if PVC end caps are used.
High Pressure Series 42 Sensors can have either a standard
NPT or Autoclave end and gauge connection. When installing
the sensor in the pipe line, be sure to tighten the end connec-
tions by gripping the end cap. Only use Teon tape on NPT
connections.
Series 44 Food Grade Sensors have Tri-Clamp® end connec-
tions, which are interchangeable with the Cherry Burrell "S"
type clamp connection.
1. The end gaskets of the Series 44 sensors are
molded into the sleeve. If the gasket needs to
be replaced, the whole sleeve must be replaced.
Make sure that the sensor is thoroughly sterilized
before installing the sensor in line.
2. Install the appropriate size clamp and tighten
to the recommended torque.
Tri-Clamp is a Registered Trademark of Ladish Co.
REPLACING SLEEVE
Replacement Sleeves are available in a wide variety of rubber
compounds. The following compounds are available: Buna-N,
Pure Gum Rubber, Butyl, EPDM, Neoprene®, Hypalon®and
Viton®. Food grade rubber is available in white: Neoprene,
EPDM, Buna-N and Butyl along with Black Viton.
Neoprene, Hypalon and Viton are Registered Trademarks of E.I.
DuPont.
1. Remove the sensor from the line.
2. Remove the gauge or instrumentation, to
avoid damaging the equipment.
3. Chip away the epoxy ll covering the pipe plug.
4. Remove the pipe plug.
5. Drain the uid from the sensor.
6. Remove the retaining bolts in the Series 40 and
Series 42, unscrew the end caps of the Series
42 and Series 44.
NOTE: Collapse the gasket/liner portion of the sleeve down to
the inside diameter on the Series 44, before unscrewing the
end caps.
7. Remove the sleeve with a blunt instrument.
8. Thoroughly clean the body and anges. Remove
any fragments of rubber or pieces of Teon
tape. Loose fragments may clog gauges or
instruments.
9. Inspect metal parts for sharp edges. Remove
any sharp edges with a ne metal le or ne
grinding wheel. Be sure to remove only enough
metal to smooth surface.
10. Clean the new sleeve and body with a compatible
uid. Thoroughly clean and sterilize the Series
44, body, end caps and sleeve.
11. Install the new sleeve. Be very careful not to
damage the sleeve with sharp instruments
during installation.
NOTE: Series 42 sleeves maybe lubricated with petroleum
jelly (Not compatible with EPDM, natural gum rubber, SBR,
and Butyl at any temp. PVC and PP at elevated temp), soapy
water or another compatible uid to ease installation. Do not
lubricate any other sleeves at this stage.
12. Series 40/48: Bolt the anges of the sensor
together until no gap exists between the anges
and the body. Be sure to tighten all of the bolts
evenly.
NOTE: Sensors with working pressures over 5,000 psi must
have the antiextrusion rings installed before the anges are
assembled.
Teon Series 40/48: Apply a layer of sealant to both sides
of the sleeve anges. Use Dow Corning Silicone Sealant,
number RTV-732-Clear, or equivalent.
Series 42: Lubricate the exposed faces of the sleeve with pe-
troleum jelly (Not compatible with EPDM, natural gum rubber,
SBR, and Butyl at any temp. PVC and PP at elevated temp),
or other compatible lubricant, and screw the end caps into the
body. Tighten the end caps until they are snug.
High Pressure Series 42: Be sure to install the anti-extrusion
rings in sensors with 5000 PSI and greater pressure ratings.
For bolted models, tighten the bolts until there is no gap
between the body and the end caps. Be sure to tighten all of
the bolts evenly.
Series 44 Food Grade Sensor: Lubricate the exposed faces
of the sleeve and the sleeve's outside diameters. Collapse the
gasket/liner area so that the end caps can be screwed on. Be
sure that the sleeve is fully engaged in the body before the
end cap is completely tightened. The end cap should bottom
out on the body when it is fully tightened. Use only approved
lubricants and completely sterile assembly conditions.
13 Reinstall the gauge or instrument. Use three
layers of Teon tape on the NPT connection.
For food grade applications use only approved
sealants.
14. Fill sensor per the instructions below.
Recommended ll uids include: a 50/50 mix
of ethylene glycol and water, distilled water,
FDA approved Silicone oil (Dow Corning 200-
350). Fluorolube, vegetable oil and mineral oil.
NOTE: For food grade applications use only sterile
ll equipment.