854071601 - 27/02/2020 - Rev.0 3/4
FMC-S
COLUMN FOR MIRRORS
GENERAL
These mounting instructions contain information about the mounting of the FMC-S column with
integrated mirror on the FMC-CB/ FMC-CBL stand bottom and about their alignment.
For information about the mounting of the stand bottom and the function of the light curtains,
please see the respective mounting and wiring instructions.
ASSEMBLY WITH THE FMC-CB/FMC-CBL STAND BOTTOM (Fig. 1)
Mount the FMC-CB/FMC-CBL stand bottom on the floor (see mounting instruction for stand
bottom).
Please note:
For a correct alignment, please verify that the stand bottom upper surface is even
and horizontal (using a circular spirit level.)
To operate the regulation, act on the three hexagonal nuts B (fig.2) until the perfect
levelness is reached. (Maximum adjustment: 10mm).
If the ground roughness is over 10mm, flush it adequately.
Loosen the three allen screws and remove the washers.
Assembly the column to the stand bottom, centering the FMC-S column rotation flange with the
guides of the FMC-CB/FMC-CBL stand bottom upper plate.
Fix the column tightening the three allen screws and the washers.
Figure 1