Regency greenfire GF55 User manual

March 2008 Product Specifications Book
2
Gas Inbuilt
Pellet Stoves & Inserts
GF55 Greenfire Pellet Stove
GF55 Wood Pellet Stove
341/8"
(866mm)
231/16"
(586mm)
19/16"
(40mm)
197/16"
(494mm)
131/16"
(332mm)
247/16"
(620mm)
24"
(610mm)
129/16"
(319mm)
1"
(25mm)
11 7/16"
(291mm)
611/16"
(170mm)
14 5/8"
(356mm)
20 5/16"
(508mm)
53/4"
(146mm)
These dimensions are minimum clearances to combustibles, however it
is highly recommended that you leave sufficient room on each side (20"
where possible) for servicing, routine cleaning and maintenance.
This pellet stove requires floor protection. The floor protection must be
non-combustible, extending 6" (150mm) beyond the full width and depth
of the unit including 6" (150 mm) in front for ember protection.
Floor Protection:
Width 36-7/16” (934mm)
Depth 36” (914mm)
Back wall
Side wall
Adjacent
wall
2"
(51mm)*
3" (76mm)
6"
(152mm)
CLEARANCES TO COMBUSTIBLES
*NOTE: If the unit is installed as a corner installation,
clearances change from 2" to 3", see "Corner thru
Wall Installation" section.

March 2008 Product Specifications Book 3
Gas Inbuilt
Pellet Stoves & Inserts
GF55 Wood Pellet Stove
ALCOVE CLEARANCES
Minimum Width
36" (914mm)
Minimum Height
48" (1219mm)
Maximum Depth
30" (762mm)
EXHAUST AND FRESH AIR INTAKE LOCATION
EXHAUST:
Base of unit to center of flue 20-5/16" (508mm)
Side of unit to center of flue 6-11/16" (170mm)
Center of unit to center of flue 5-3/4" (146mm)
FRESH AIR INTAKE:
Base of unit to center of intake 14-5/8" (356mm)
Side of unit to center of intake 11-7/16" (291mm)
Center of unit to center of intake 1" (25mm)
1"
(25mm)
11 7/16"
(291mm)
611/16"
(170mm)
14 5/8"
(356mm)
20 5/16"
(508mm)
53/4"
(146mm)
MOBILE HOME INSTALLATION
● Secure the heater to the floor using the holes in the pedestal of the
appliance.
● Ensure the unit is electrically grounded to the chassis of your home
(permanently).
WARNING: Do not install in a room people sleep in.
CAUTION: The structural integrity of the manufactured home floor,
wall and ceiling/roof must be maintained
• Outside fresh air is mandatory. Secure outside air connections directly to
fresh air intake pipe and secure with three (3) screws evenly spaced.
OUTSIDE FRESH AIR CONNECTION
Outside fresh air is mandatory when installing this unit in airtight
homes and mobile homes.
A Fresh-air intake is strongly recommended for all installations.
Failure to install intake air may result in improper combustion as well as
the unit smoking during power failures.
When connecting to an outside fresh air source, do not use plastic or
combustible pipe. A 2” minimum (51 mm) ID (inside diameter) steel,
aluminum or copper pipe should be used. It is recommended, when you
are installing a fresh air system, to keep the number of bends in the pipe
to a minimum.
2" ID
(51 mm)
Optional
Elbow
Outside
Wall
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING
MANUFACTURER.

March 2008 Product Specifications Book
4
Gas Inbuilt
Pellet Stoves & Inserts
VENT TERMINATION REQUIREMENTS
1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced
area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, etc.
2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appli-
ance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power
failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest
and preferred venting method is to extend the vent through the roof vertically.
4. Distance from the bottom of the termination and grade is 12” (30 cm) minimum. This is conditional upon the plants and nature of grade surface.
The exhaust gases are hot enough to ignite grass, plants and shrubs located in the vicinity of termination. The grade surface must not be lawn.
5. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since these
factors are beyond the control of FPI, we grant no guarantee against such incidents.
NOTE: Venting terminals shall not be recessed into walls or siding.
Air Supply Inlet Gas Meter Restriction Zone
(Termination not allowed)
Termination Cap
G
G
Opens
Opens
Opens
DF
B
B
AI
H
K
G
G
L
C
E
Letter Minimum Clearance Description
A 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials.
B 48 in (122 cm) From beside/below any door or window that may be opened.
C 24 in (61 cm) From above any door or window that may be opened.
D 24 in (61 cm) To any adjacent building, fences and protruding parts of the structure.
E 24 in (61 cm) Below any eave or roof overhang
F 12 in (30 cm) To outside corner.
G 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations).
H 3 ft (91 cm) within a height of 15 ft (4.5 m)
above the meter/regulator assembly To each side of center line extended above natural gas or propane meter/
regulator assembly or mechanical vent.
I 3 ft (91 cm) From any forced air intake of other appliance
J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building, or the combustion air
inlet to any appliance.
K 24 in (61 cm) Clearance above roof line for vertical terminations.
L 7 ft (2.13 m) Clearance above paved sidewalk or paved driveway located on public property.
GF55 Wood Pellet Stove

March 2008 Product Specifications Book 5
Gas Inbuilt
Pellet Stoves & Inserts
HORIZONTAL EXHAUST
THROUGH WALL INSTALLATION
Exhaust Tube
3" (75mm) or 4" (100mm)
"PL" or "L" vent
Wall Thimble
45° Elbow with screen
or Termination Cap
Fresh Air Intake High Temperature RTV
Silicone Required
GF55 Wood Pellet Stove
VERTICAL RISE WITH HORIZONTAL
TERMINATION INSTALLATION
THROUGH CONCRETE WALL
WITH VERTICAL RISE INSTALLATION
3" (7.5 cm)
3"
(7.5 cm)
Fresh Air Intake
Wall thimble
manufactured
by pellet vent
manufacturer.
CORNER THROUGH WALL INSTALLATION
A chimney connector shall not pass through an attic or roof space, closet
or similar concealed spaces, or a floor, or ceiling. Where passage through
a wall or partition of combustible construction is desired, the installation
shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning
Appliances and Equipment. Only use venting of L or PL type with an inside
diameter of 3 or 4 inches (7.6 or 10.1 cm).
A 45° elbow with a rodent screen may be used in place of the termination
cap (or stainless steel termination hood).
A 45° elbow with a rodent screen may be used in place of the termination
cap (or stainless steel termination hood).
This is the recommended installation to use if there is a concrete or retain-
ing wall in line with exhaust vent on pellet stove.
The termination must be 12 inches (30 cm) from the outside wall and 12
inches (30 cm) above the ground.

March 2008 Product Specifications Book
6
Gas Inbuilt
Pellet Stoves & Inserts
GF55 Wood Pellet Stove
INSIDE VERTICAL INSTALLATIONS
Rain cap - ensure cap is at
least 2 feet (610mm) above
the roof at the lowest point
Storm collar
Roof flashing
Roof rafter
Fire stop with
Support Collar
Ceiling joist
Vertical vent pipe
Clean out tee with
Pipe adapter
NOTE:
All vent sections must maintian 3"
(76 mm) clearances to combustibles.
OUTSIDE VERTICAL INSTALLATIONS
Rain cap
Flashing
24"
(61 cm)
3"
(7.5cm)
Tee with
cleanout
Fresh air
intake
3" (7.5 cm)
Clearance
Support
bracket
Type "L", "PL" or
all fuel vent
HEARTH MOUNT INSTALLATION
Floor
Protection
Combustible FloorMasonry Fireplace
Min 6"
(150 mm)
Mantel
Minimum 8" (20 cm)
from top of stove
Damper Removed
or Fastened Open
Clean-out
Fresh-air intake
should com from
chimney. If holes
a
lready exist fresh-air
intake can be taken
through back of the
fireplace or through
the ash dump.
Other manuals for greenfire GF55
1
Table of contents
Popular Pellet Stove manuals by other brands

Harman
Harman P43 Installation & operating manual

Enviro
Enviro Empress owner's manual

Enviro
Enviro EF2 Service manual

COUNTRY FLAME TECHNOLOGIES
COUNTRY FLAME TECHNOLOGIES LR-01 Installation, operation and maintenance manual

Drolet
Drolet ECO-55 Operation manual

Moretti Design
Moretti Design ARIA ERGONOMIC GLASS A/C/RELAX CLEAN DEDICATED MANUAL