6
REMKO GPS series
side section the necessary components for the control
and safety are found behind the inspection door,
including e.g.:
- the electrical circuitry with the cabling
- the control electronics
- the gas valve
- the modulating gas burner
In the interior of the unit, directly in the circulation air
flow, is the combustion chamber with heat exchanger.
The combustion chamber is manufactured entirely
from Inox stainless steel, AISI 441. For increased
resistance to corrosion from damp vapours, Inox
stainless steel, AISI 441 is used for the heat exchanger.
The special form and the large surface area of the
combustion chamber and heat exchanger guarantee a
high level of efficiency and long service life.
The gas burner is likewise manufactured entirely from
special, mechanically-processed stainless steel.
Function of the units
The modulating, gas wall-mounted automatic heaters
of the GPS series has been developed for the heating
of industrial and commercial spaces.
The electronic control of the unit regulates the heat
output according to the actual requirement, between
minimum and maximum output.
With the pre-mix and modulation technology,
efficiency of up to 108% can be achieved.
The nominal heating capacity of the REMKO GPS
series lies between 4.7 and 82.0 kW.
The units consist primarily of the combustion chamber
with heat exchanger and the fan(s).
The ambient air is drawn in by the fan(s) and
efficiently channelled through the combustion
chamber with heat exchanger. The combustion
chamber is heated by the gas burner operation and
releases its heat to the air flowing past. The air heated
in this manner is blown out of the front side of the
unit through an adjustable outlet grille.
Operation of the unit as intended is only possible with
a connected temperature controller.
Unit description
Definition of the unit
Pursuant to EU Directives, the unit is defined as:
“Gas fan-assisted heater (WLE) without flow-
operated safety device, equipped with a fan in front
of the heat exchanger”.
The unit is a fully-automatic, directly-fired fan-assisted
air heater for wall and ceiling installation.
It can be fuelled with natural gas or liquid gas.
The unit is used for continuous and temporary
heating of open and closed spaces, e.g. in:
halls, workshops,
greenhouses,
storage rooms, etc.
Classification of the units
The units have been classified by the European
standardised regulations
EN 437, EN1196 and EN 1020 according to:
The gas category:
Determination according to the type of gases with
which they may be operated.
For Germany DE II2ELL3B/P
The gas type:
The burner can be operated with gases of the second
family (natural gas - group H and L) and with gases of
the third family (butane and propane).
The type of gas fireplace:
Differentiation according to the possibilities of the
discharge of the combustion products or the supply of
the combustion air.
(ambient-air-dependent/independent)
Additional notes can be found in the chapter
“Installation of the flue gas evacuation and the
combustion air supply”.
Design of the units
The exterior cladding of the units is made from coated
steel sheet, which guarantees durability.
The outlet grille is found in the front section.
In order to ensure an optimal distribution of warm air
in the installation location, the horizontal fins of the
outlet grille can be manually adjusted. On the rear
side of the unit you will find the fan(s) with protection
grid, the connection nozzles for the removal of
the flue gas and supply of the combustion air, the
gas connection nozzles, the cable passages for the
electrical lines as well as the plug connection for the
mains power supply connection. In the right-hand