manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Renkus-Heinz
  6. •
  7. Speakers System
  8. •
  9. Renkus-Heinz ICL-R User manual

Renkus-Heinz ICL-R User manual

Other manuals for ICL-R

2

This manual suits for next models

5

Other Renkus-Heinz Speakers System manuals

Renkus-Heinz IC Live Fixed NON RHAON ICL-F User manual

Renkus-Heinz

Renkus-Heinz IC Live Fixed NON RHAON ICL-F User manual

Renkus-Heinz IC Squared User manual

Renkus-Heinz

Renkus-Heinz IC Squared User manual

Renkus-Heinz ICONYX IC8-RN User manual

Renkus-Heinz

Renkus-Heinz ICONYX IC8-RN User manual

Renkus-Heinz VARIA VA101-7 User manual

Renkus-Heinz

Renkus-Heinz VARIA VA101-7 User manual

Renkus-Heinz ICL-F-RN User manual

Renkus-Heinz

Renkus-Heinz ICL-F-RN User manual

Renkus-Heinz Loudspeaker User manual

Renkus-Heinz

Renkus-Heinz Loudspeaker User manual

Renkus-Heinz Iconyx IC Live ICL-R User manual

Renkus-Heinz

Renkus-Heinz Iconyx IC Live ICL-R User manual

Renkus-Heinz Iconyx IC8-R User manual

Renkus-Heinz

Renkus-Heinz Iconyx IC8-R User manual

Renkus-Heinz RHAON User manual

Renkus-Heinz

Renkus-Heinz RHAON User manual

Renkus-Heinz iConyx DC12/2 User manual

Renkus-Heinz

Renkus-Heinz iConyx DC12/2 User manual

Renkus-Heinz ICL-FR User manual

Renkus-Heinz

Renkus-Heinz ICL-FR User manual

Renkus-Heinz STXLA User manual

Renkus-Heinz

Renkus-Heinz STXLA User manual

Renkus-Heinz DC12/2 User manual

Renkus-Heinz

Renkus-Heinz DC12/2 User manual

Renkus-Heinz iConyx IC Live X Series User manual

Renkus-Heinz

Renkus-Heinz iConyx IC Live X Series User manual

Renkus-Heinz Iconyx IC8-R User manual

Renkus-Heinz

Renkus-Heinz Iconyx IC8-R User manual

Renkus-Heinz iConyx IC LIVE ICL-FR User manual

Renkus-Heinz

Renkus-Heinz iConyx IC LIVE ICL-FR User manual

Renkus-Heinz IC Live FRO Series User manual

Renkus-Heinz

Renkus-Heinz IC Live FRO Series User manual

Renkus-Heinz RHAON User manual

Renkus-Heinz

Renkus-Heinz RHAON User manual

Renkus-Heinz PCX Series User manual

Renkus-Heinz

Renkus-Heinz PCX Series User manual

Renkus-Heinz ICL-R User manual

Renkus-Heinz

Renkus-Heinz ICL-R User manual

Popular Speakers System manuals by other brands

Monster MT-SB21 user manual

Monster

Monster MT-SB21 user manual

Monacor ESP-76AB/ WS manual

Monacor

Monacor ESP-76AB/ WS manual

Samsung HW-J430 user manual

Samsung

Samsung HW-J430 user manual

WILSON AUDIO WATT owner's manual

WILSON AUDIO

WILSON AUDIO WATT owner's manual

Hisense AX3125H user manual

Hisense

Hisense AX3125H user manual

EisSound KBSound iSelect user manual

EisSound

EisSound KBSound iSelect user manual

Boston Acoustics VRi793 manual

Boston Acoustics

Boston Acoustics VRi793 manual

Sven SPS-707bL Operation manual

Sven

Sven SPS-707bL Operation manual

Monacor DSM-26LAN instruction manual

Monacor

Monacor DSM-26LAN instruction manual

JVC CS-SR100 instructions

JVC

JVC CS-SR100 instructions

Samsung HW-C450 user manual

Samsung

Samsung HW-C450 user manual

TaoTronics evatronic ET-SK011 user guide

TaoTronics

TaoTronics evatronic ET-SK011 user guide

JVC HX-D7C instructions

JVC

JVC HX-D7C instructions

Pyle PBMSPG190 user manual

Pyle

Pyle PBMSPG190 user manual

Sven SPS-607 Operation manual

Sven

Sven SPS-607 Operation manual

iSP Technologies LT2 series owner's manual

iSP Technologies

iSP Technologies LT2 series owner's manual

Samsung Crystal Surround Air Track HW-F550 user manual

Samsung

Samsung Crystal Surround Air Track HW-F550 user manual

Bose Acoustimass 6 Series II owner's guide

Bose

Bose Acoustimass 6 Series II owner's guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Owners Manual
USE S MANUAL
Assembly
&
Installation Instructions
ICL-R
ICL-FR &ICL-FR-DUAL
IC Live
Digitally Steerable Line Array Loudspeaker Systems
22
IMPO TANT SAFETY INST UCTIONS
CAUTION
To reiterate the above warnings: servicing instructions are for
use by qualified personnel only. To avoid electric shock, do
not perform any servicing other than that contained in the Ope-
ration Instructions unless you are qualified to do so. Refer all
servicing to qualified personnel.
Eindrigliche Warnung: Wartungsvorschriften dienen nur der
Benutzung durch qualifizieres Personal. Zur Vermeidung eines
elektrischen Schlages keine anderen als die in den Betriebsvor-
schriften beschriebenen Wartungsarbeiten ausführen, es sei denn
Sie sind dafür qualifiziert. Wartungsarbeiten auszuführen.
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the use to the presence of uninsulated
"Dangerous Voltage" within the product's en-
closure that may be of sufficient magnitude
to constitute a risk of electric shock to hu-
mans.
The exclamanation point, within an equilateral
presence of important operating and mainte-
nance (servicing) instructions in the literature
accompanying the product.
VORSICHT
RISK OF ELECTRONIC SHOCK:
OPEN ONLY IF QUALIFIED AS
SERVICE PERSONNEL
GEFAHR EINES ELEKTRISCHEN SCHLAGES:
NUR VON QUALIFIZIEREM WARTUNGSPERSONAL
ZU ÖFFNEN
Der Blitz mit nach untenzielendem Pfeil in
einem gleichseitigen Dreieck weist den
Benutzer auf das Vorhandensein einer
unisolierten, "gefährlichen Spannung" im
Gehäuse hin, die stark genug sein kann, einer
Person einen gefährlichen elektrischen Schlag
zu versetzen.
Das Ausrufezeichen in einem gleichseitigen
Dreieck weist den Benutzer auf wichtige
Betriebs- und Wartungsvorschriften in den
beiliegenden Unterlagen des Gerätes hin.
Erklärung der graphischen SymboleExplanation of Graphical Symbols
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions
5. o not use this apparatus near water. The apparatus shall not be
exposed to dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on it.
6. Clean only with dry cloth.
7. o not block any ventilation openings. Install in accordance with
the manufacturer’s instructions.
8. o not install near any heat sources such as radiators, heat regis-
ters, stoves, or other apparatus (including amplifiers) that produce
heat.
9. o not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong is provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particular-
ly at plugs, convenience receptacles, and the point where they exit
from the apparatus.
11. Make sure the power cord remains readily accessible at all times.
12. The AC Power Cord is the AC Mains disconnect.
13. Only use attachments/accessories specified by the manufacturer.
14. isconnect this apparatus during lightning storms or when
unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such as
power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.
“WA NING - TO EDUCE THE ISK OF FI E O ELECT IC
SHOCK, DO NOT EXPOSE THIS APPA ATUS TO AIN O MOIS-
TU E”
“CAUTION: THESE SE VICING INST UCTIONS A E FO USE
BY QUALIFIED SE VICE PE SONNEL ONLY. TO EDUCE THE
ISK OF ELECT IC SHOCK DO NOT PE FO M ANY SE VICING
OTHE THAN THAT CONTAINED IN THE OPE ATING INST UC-
TIONS UNLESS YOU A E QUALIFIED TO DO SO”.
IMPO TANT
Your Iconyx Steerable Column Loudspeaker contains no user-serviceable
parts and all service should be referred to qualified service personnel.
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
TABLE OF CONTENTS
Page
Introduction 4
General Information 4
Assembly Instructions 4
Address Number Verification 6
Introduction To HAON 7
RHAON Organization 8
Preparation 10
Computer Requirements 10
Software Installation 10
Virtual Systems 12
Assigning a Static IP Address 13
Saving Your Work 15
Connect Mode 16
Linking Software With Networked Loudspeakers 16
Properties Windows 18
Assigning igital & Analog Inputs 20
CobraNet Signal Routing 21
Beam Steering 23
Presets 31
Control Mode 32
User Configurable SP Functions 33
Saving Changes 34
All Loudspeakers Control 35
Group Control 36
Copy/Paste Shortcut 37
Supervise Mode 38
Event Logging & Notification 40
General Preferences 41
Password Protection 42
Installation 44
Wall Mounting 44
Suspended (Flying) 45
Servicing 45
Trouble Shooting Hints 45
Appendix I
Audio Evacuation & Life Safety Functions 46
Appendix II:
RHAON System Block iagrams 47
Appendix II
IC-R Hardware Inputs, Outputs & Indicators 50
IC-R imensions 51
Appendix IV:
Keeping Your RHAON Program Up-To- ate 53
Networking and HAON Systems 60
HAON Network Trouble Shooting Tips 61
Index 63
333
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
INT ODUCTION
Congratulations on your purchase of a Renkus-Heinz RHAON Empowered digitally steered Iconyx IC Live column loudspeaker. We
hope you enjoy it.
Your Iconyx IC Live steerable column loudspeaker was carefully tested and inspected before leaving our factory and should have
arrived in perfect condition. Please carefully inspect the shipping carton(s) and loudspeaker(s) for any noticeable damage, and if any
damage is found, immediately notify the shipping company. Only you, the consignee, may institute a claim with the carrier for any
damage incurred during shipping. Be sure to save the carton(s) and all packing material for the carrier’s inspection. It is also a good
idea to save the carton and packing material even though the loudspeaker arrived in good condition. If you should ever need to ship
the loudspeaker, it should be shipped in its original factory packaging.
TECHNICAL SUPPO T
If you have any questions about RHAON-Empowered Loudspeakers or encounter a problem designing, installing, setting up or oper-
ating a RHAON system, please call our technical support staff at 949-588-9997 and ask the operator for technical support on
RHAON. Call Monday through Friday from 8:00 AM to 5:00 PM Pacific Time.
The latest information on RHAON Technical Support is always available online at http://www.renkus-heinz.com/support/software-sup-
port/rhaon/e-mail.html. You will also find a support request form at http://www.renkus-heinz.com/support/request-info/tech-
info/index.html.
IMPO TANT INFO MATION
Portable IC Live arrays and their ICL-F & ICL-F -DUAL fixed installation counterparts are nearly identical
except for their assembly/mounting hardware. The following instructions were written for the the fixed
installation models. Owners of Portable IC Live arrays should refer to their IC Live Operators Guide for
assembly and operating instructions.
ICL-F -DUAL ASSEMBLY INST UCTIONS
To simplify shipping and handling, ICL-FR- UAL arrays are shipped as two modules in separate cartons and
need to be assembled in the field. All the hardware needed to assemble the ICL-FR- UAL is included in the car-
tons.
If you ordered a HK-ICL-F2 mounting hinge kit with your ICL-F- UAL array, the top and bottom female portions of
the hinge assembly will have been installed on the modules for you; the third center hinge assembly will be
packed with the other hardware.
In the following instructions, the term “module” is used to refer to one of the 8-channel sections of the finished
assembly, which is called a column or a column array.
Prepare an assembly area. Each module is 4 feet long, so you need a flat surface at least 8 feet long to assemble
the dual array. We suggest covering the assembly area with a heavy cloth or some other soft material to prevent
damaging the finish on the cabinets while assembling them.
Avoid resting the modules on their grille. The modules are heavy and may deform the grille. Instead, rest the
modules on their sides or back.
Place the modules in their respective positions on the assembly area.
Note: The proper way of assembling the two modules is to join the horn sections together as shown in this photo.
344
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
55
Attach the heavy joining plate to the rear of the cabinet using the
machine screws provided with the hardware. See below. Tighten
the screws loosely to allow a little movement while joining the two
modules.
Plug one end of the flat wire signal cable into the socket provided.
It only goes into the socket one way and the cable is reversible. It
does not matter which end goes into which module. Using a #1
Phillips screw driver, secure the connector with two 4-40 Phillips
head screws (supplied). Make sure the connector is fully seated.
See below.
If you purchased two ICL-F arrays separately and now want to
turn them into a ICL-F- UAL array, you will first need to remove
the top of one module and the bottom of the other module. You
will also need an ICL-F-UP joining kit..
If you purchased an ICL-F- UAL array, the top of one module
and the bottom of the other module will have been removed for
you by Renkus-Heinz prior to shipping.
To remove the top/bottom, remove the eight machine screws
from each side of the cabinet and lift the end piece and its
mounting brackets out of the cabinet as shown.
Now, use the mounting bracket machine screws you removed to
install the two heavy joining plates. (They will be packed with the
hardware if you ordered an ICL-FR- UAL).
Tighten the screws lightly. The joining plates need to be a little
loose to slide easily into the other cabinet.
Refer to graphic at the top right of this page.
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
6
Align the two modules to be joined on a tabletop or on the floor so that the top of the lower one and the bottom
of the upper one are close to one another, say 4” (10 cm) apart.
Insert the free end of the short ribbon cable into the socket on the second module. Using a small Philips screw
driver, secure the connector with two 4-40 Philips head screws (supplied). Make sure the connectors are fully
seated. If necessary, use a flashlight to check because if the connectors are not seated properly, you may have
to disassemble the column in order to seat them correctly.
Align the two modules and slide them together, making sure the holes in the heavy joining plates align with the
holes in the modules. Install the remaining screws into the joining plates and tighten all the screws.
The assembly is now complete.
Address Number Verification
All that remains is to identify which module is the Master and which is the Slave. This is
accomplished with the Master/Slave dip switches located on the input panel. See page 50 for
a detailed view of the input panel.
The bottom modules will be the Master and the top module the Slave. Set both dip switches
on the bottom module to “00” (off & off) and the dip switches on the top module to “01” (on &
off). On single ICL-FR arrays the dip switches should always be set to the Master setting
(“00”).
Note that certain functions will be disabled on the Slave module as their control has been
turned over to the Master module. Preset Up, Preset own, Preset Enter , Input Pad, Volume Up & Volume own, AES/EBU Input and
Mute functions are all controlled only by the controls on the Master module. Signal cables must be brought into the Master module. AC
power must be brought separately into the two modules.
MASTER
SLAVE
MASTER
SLAVE
Master Switch
Setting
Slave Switch
Setting
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
INT ODUCTION TO HAON
Your digitally controlled, steerable Iconyx IC Live ICL-FR series column loudspeaker is RHAON Empowered.
HAON
RHAON (“rayon”), the Renkus-Heinz Audio Operations Network, is the first practical system to combine digital audio distri-
bution with precise control and supervision of self-powered loudspeakers. RHAON uses standard Ethernet hardware,
advanced CobraNet technology and on-board SP (digital signal processing) to turn self-powered Renkus-Heinz loud-
speakers from “black boxes” into “smart boxes” that can respond to user input in real time.
Multi-dimensional RHAON technology lets you:
• Connect multiple loudspeakers with multiple channels of high quality digital audio via CobraNet; identify CobraNet
devices and link them using an intuitive point-and-click interface; set up IC Live steerable arrays and their beams; store
preset configurations.
• Control every RHAON-Empowered loudspeaker on the network. A computer running Windows-based RHAON software
gives you password-protected access to the powerful SP inside each RHAON hardware module.
• Supervise the entire system’s operation and performance over the network using RHAON software. Supervise mode
includes logging and operator alert functions.
You can use all three RHAON modes, or any combination of them. For instance, each RHAON hardware module has dual
analog inputs and a serial digital audio input (often called an AES/EBU input) along with redundant Ethernet connections.
General Information
Your RHAON-Empowered Loudspeaker’s amplifier stores all onboard SP settings, including the input source selection, in
non-volatile memory. Analog Input 1 has been pre-selected at the factory so you can use the loudspeaker as an ordinary
self-powered loudspeaker. Just connect a line level audio signal to Analog Input 1, connect the AC power and turn the
loudspeaker on. This input is always available for testing the loudspeaker and amplifier, regardless of the programmed
input settings.
You will need a computer with a NIC (Network Interface Card) and Windows-based RHAON software to change the input
selection or any of the other SP settings. Once your SP settings are stored in non-volatile memory, the computer can
be disconnected from the network. You will need to connect a computer only when you want to change the settings or
when you want to use the supervise feature.
Renkus-Heinz engineering has programmed the onboard SP to optimize the loudspeaker’s performance and to ensure
its safe operation. Replace the RHAON hardware module only with another unit that has been factory programmed for the
same loudspeaker. Contact our Technical Support epartment for details and assistance.
Access Control Note
RHAON systems feature several levels of password-protected access control to prevent inadvertent or unauthorized
changes of the control settings. Even when you connect a computer running RHAON software, you may be denied access
to some or all of the Connect and Control mode functions, depending on how the access control system is configured. For
further information on password protection refer to page 40 of this manual or contact the person responsible for the setup
and tuning or commissioning of your system.
Important
Several functions are described in this manual that may not yet be supported by the software version you are using. In
many cases these missing features are not essential, but if they are for you, please check our website for available
updates. Go to www.renkus-heinz.com and click on the RHAON button on the left side of the Home page. You’ll see the
link to the latest version at the top of the page. For more detailed information on keeping your system up-to-date, refer to
pages 53 to 59 of this manual.
In case the updates do not correct your problem and the missing function is important to you, please contact our Technical
Support group by phone or e-mail.
377
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
HAON O GANIZATION: Three Fundamental Audio Operations
Before we go on, let’s take a look at the structure of RHAON. Audio operations comprise three fundamental areas that are nec-
essary for the success of any sound system:
CONNECT
In a RHAON system there are both physical connections and network (software) connections. The physical connections are
made using UTP cable meeting at least CAT5e standards and/or analog cables as well as AC power cords. Network connec-
tions are established in the software. You don’t have to make the two types of connections in a particular order. RHAON soft-
ware allows you to set up a “virtual system” using beam steering, pre-configure SP settings for individual loudspeakers and
establish and store preset configurations before the physical connections are made. If you are using RHAON’s CobraNet digital
audio functions, you will also need to connect a CobraNet source (an analog to CobraNet converter) to the network.
CONT OL
You can control many SP parameters in real time, and/or pre-configure them in software prior to installation and make final
adjustments during commissioning or setup. Preset configurations are available for instant recall.
SUPE VISE
RHAON allows both real-time supervision while the system is in use, and remote supervision with fault logging and operator
alerts via e-mail, text messaging, etc. In steerable arrays, every single driver is supervised and its status displayed, any failures
detected trigger an alarm.
At any time you can switch into any of the three RHAON modes using the Connect | Control | Supervise tool bar directly above
the work space. You can also switch between the three modes using tabs inside the Loudspeaker Properties windows.
8
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
TYPICAL PROJECT WORKFLOW
P E P A A T I O N
CONNECT
C O N T O L
SUPE VISE
INSTALL RHAON
software under
Windows 2000,
Windows XP
CHOOSE BACKGROUND I AGE
This can make it easier to see
where Groups and Loudspeakers
are in the venue
ADD VIRTUAL SPEAKERS
or scan network for actual
loudspeakers
GROUP VIRTUAL SPEAKERS
or group actual loudspeakers
found on your network
SET STATIC IP ADDRESS TO 192.168.1.1
(or a different value if you need to).
192.168.xxx.xxx are local IP addresses
that won’t appear on the Web.
PRESETS
Control & Store
Presets
SCAN THE NETWORK
RHAON assigns
IP Addresses as needed
ASSOCIATE VIRTUAL &
ACTUAL LOUDSPEAKERS
Drag from left panel,
drop on icon in right panel
SELECT DIGITAL and/or
ANALOG INPUTS
ROUTE COBRANET
CobraNet Source
Drag-and-Drop Tx/Rx links
EQUALIZATION
8-band parametric EQ,
hi-and lo-shelving
hi-pass and lo-pass
CO PRESSION
Threshold / Ratio
Attack / Release
Soft Knee / Trigger Point
DELAY
0 to 340 milliseconds @ 48 kHz
0 to 170 milliseconds @ 96 kHz
PRIORITY OVERRIDE
Attack / Release
Threshold / Hold
Engage / Disengage
BEA STEERING
Configure and Aim
Array’s Sonic Beams
OPERATOR ALERTS
RHAON indicates problems
such as over temperature,
clipping or driver failure at
System, Group and
Loudspeaker levels
DETAILED INFOR ATION
Just click through to the
loudspeaker’s Supervise screen
to identify the nature of the
problem and take corrective
action
FAULT LOGGING
RHAON logs the fault
conditions you specify to a
file on your hard drive
OPERATOR NOTIFICATION
via e-mail or text message
(if your computer has a second
NIC with an Internet
connection)
ULTI-LEVEL PASSWORD
PROTECTION
restrict access to Connect and
Control functions
9
CONTROL PANEL
Configure Loudspeaker
Array
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL
P E PA AT I O N
10
Software Installation
You need a Windows PC running RHAON software in order to maximize the performance of RHAON-Empowered loudspeakers and
your RHAON system. You can use RHAON software during the design stage, for system setup, tuning and commissioning, and for
remote control and supervision. You can disconnect the computer from the network after commissioning the system, if you or your
client are not using RHAON’s system supervision capabilities.
RHAON software will run on any PC computer that meets or exceeds the following requirements.
Processor / Speed: Pentium / 800 MHz minimum (faster recommended, especially for large systems)
RAM: 256 MB minimum (more recommended, especially for large systems)
Interface: At least one Network Interface Card (NIC) with a 100 BaseT (100 MB/second) or faster
Ethernet Port; two NICs are needed if the computer will also be used to e-mail alerts
Operating System: Windows XP
Associated Software: .NET Framework 3.5 or higher (supplied with RHAON installation C )
Screen Resolution: 1024 x 768 or higher
To install the software insert the RHAON Installation isk into the computer’s C drive. The installation program should start auto-
matically. If it doesn’t, go to your Start menu. Then select Settings/Control Panel & Add/Remove Programs. Click on Install to start
the installation manually.
If you have an older version of RHAON installed, a prompt will inform you that you must remove the older version before installing
the new version. Use Control Panel & Add/Remove Programs to remove the older version and then restart the Setup program.
The RHAON Setup window shown below will open.
Click on Next to proceed to the next step. Then follow the screen prompts until the installation is complete.
uring the installation you will be asked if you want to install the CobraNet Components. Answer “Yes”, even if you will not be using
CobraNet digital audio distribution. These CobraNet files are needed by RHAON for control and supervision.
IC Live Users Manual. Models: ICL- , ICL-F & ICL-F -DUAL