Renu Electronics WP6 Plus Web HMI Series User manual

User Manual
WP6 Plus Web HMI Series®

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 2of 23
Table of Contents
INTRODUCTION...............................................................................................................................................................3
BEFORE YOU START .....................................................................................................................................................3
SAFETY PRECAUTIONS.................................................................................................................................................4
PRODUCT OVERVIEW....................................................................................................................................................5
INSTALLATION OF THE WEB HMI PRODUCTS......................................................................................................................5
PRODUCT SPECIFICATIONS...............................................................................................................................................8
PRODUCT NOMENCLATURE /ORDERING PART NUMBER.....................................................................................................8
DISPLAY SPECIFICATIONS.................................................................................................................................................8
CPU, MEMORY AND POWER SUPPLY................................................................................................................................9
COMMUNICATION INTERFACES........................................................................................................................................10
DEFAULT PRODUCT SETTINGS..................................................................................................................................11
ENVIRONMENTAL SPECIFICATIONS AND APPROVALS ........................................................................................................11
POWERING UP THE WEB HMI SERIES.......................................................................................................................12
GETTING STARTED WITH THE WEB HMI...................................................................................................................12
MAIN SETTINGS .............................................................................................................................................................12
ENTERING INTO DEVICE SETTINGS...................................................................................................................................13
ON-SCREEN KEYBOARD SETTING...................................................................................................................................18
WEB APPLICATION.........................................................................................................................................................19
REVISION HISTORY......................................................................................................................................................22
NOTES............................................................................................................................................................................23

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 3of 23
Introduction
The Web HMI is a ThinClient with an inbuilt browser which connects to a remote web server on
its network.
All WP6 Plus devices are compliant with EMC directive 2014/30/EU and LVD directive
2014/35/EU and certified for UL Class I Div. 2.
This user manual gives a detailed information regarding the hardware specifications, operating
conditions, installation, mounting and wiring. All the information published in this manual is
produced and governed by RENU Electronics Pvt. Ltd. and is protected by Indian Copyright Act.
Before you start
RENU Electronics Pvt. Ltd is not responsible or liable for any indirect or consequential
damage resulting from the use of this product.
The user should check and confirm the suitability of the product before using in any specific
application.
The diagrams and examples in this manual are included for illustration purposes only. RENU
Electronics assume no responsibility or liability regarding actual use based on the diagrams
or examples shown.
Reproduction of the contents of this manual, in any form (in part or in whole), is strictly
prohibited.
Following table shows various symbols that may be used in this manual to provide information
regarding safety, precautions and usage of the product:
WARNING: Indicates circumstances that may cause an explosion in hazardous
environment, which may lead to injury or death, damage or economic loss
CAUTION: Indicates specific precautions to be taken by user during installation,
operation and maintenance of the product
ATTENTION
ATTENTION: Indicates important information regarding application and functions of
the product

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 4of 23
Safety Precautions
This section of the manual provides information which is critical regarding safety and therefore
the user is advised to go through the information in detail before installing the product. User may
specific question(s) related to safety.
WARNING: EXPLOSION HAZARD
Do not disconnect equipment unless power has been removed or the area is known
to be non-hazardous.
Substitution of any component may impair suitability for Class I, Division 2.
Secure any external connections that are made to this equipment by using screws,
sliding latches, threaded connectors or any other means provided with this product.
If this product contains batteries, they must only be changed in an area known to be
nonhazardous.
CAUTION: GENERAL PRECAUTIONS
Do not use this product for emergency stop. A separate physical switch, outside the
product must be used for any emergency stop operations.
Do not use the external power supply source that does not comply with the specified
power requirements of the product, it may cause malfunction or permanent damage
to the product.
Do not attempt to open, dismantle or modify the product, doing so will void the
warranty.
This product is supplied as open-type equipment and it must be mounted within an
enclosure, suitably designed for specific environmental conditions.
When used in Class I, Division 2 hazardous location, the product must be mounted
in a suitable enclosure with proper wiring method that complies with the governing
electrical codes.
The USB port is intended for temporary local programming purposes only and not
intended for permanent connection. If you connect or disconnect the USB cable with
power applied to this product or any other device on USB network, and electrical arc
can occur, which could cause explosion in hazardous location installations.
Make sure that connectors are securely tightened to properly seal the connections
against leaks.
Do not place the product in direct sunlight. Prolonged exposure to sunlight may
degrade the LCD and housing.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 5of 23
Product Overview
This section of the manual provides an overview of Web HMI series products, its front and back view, installation
details, dimensional details, mounting method and details.
Installation of the Web HMI products
Web HMI series products are designed for front panel mounting. Before installing the products, user should review
the panel guidelines, panel cutout dimensions, product dimensions and minimum clearances.
Panel Guidelines
The panel must be at least 2mm (12 gauge), in order to provide the required support and proper sealing against
water and dust. The panel surface must be flat, devoid of any imperfection, to maintain adequate seal and IP rating.
The maximum panel thickness on which this HMI can be mounted is 6mm (±0.2mm).
Panel Cutout Dimensions
Model
Height (mm)
Width (mm)
WP6043TN Plus
80
111
WP6070TN Plus
127
175
WP6101TN Plus
178
256
ATTENTION
ATTENTION: Panel cutout
Before cutting out the panel, disconnect all electrical power from the panel.
Make sure that the area surrounding the panel cutout is clear.
Make sure that metal cutting chips do not enter any other component, already
installed in the panel.
Product Dimensions
This section of the manual provides dimensional details of Web HMI series products. All the dimensions shown
below are measured in mm.
WP6043TN Plus

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 6of 23
WP6070TN Plus
WP6101TN Plus

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 7of 23
Minimum Clearances
Maintain minimum clearance of 2” from enclosure walls, wires and other adjacent devices on all sides for adequate
ventilation. Plan for adequate space around the product and inside the enclosure for ventilation and cabling. Take
into consideration the heat produced by other devices in the enclosure. The operating temperature for this product
is between 0° to 50°C. Care should be taken in-order to maintain the ambient temperature around the Web HMI
within this range.
Mounting Web HMI Products
Web HMI series products must be installed on the front panel, using the clamp accessories shipped with the product.
Before mounting, make sure that sealing gasket is properly positioned. This gasket forms a compression type of
seal. Do not use sealing compounds. Place the unit in the panel cutout and tighten the mounting screws evenly
(torque 0.4Nm) to maintain water and dust resistance.
ATTENTION
ATTENTION: Mounting Web HMI on Panel
Do not push directly on the LCD display of the HMI when placing the unit into the
panel as it may damage the display. Push on the bezel or the border of the LCD
display.
Connecting Power
Web HMI series require 24VDC to operate. Follow the steps mentioned below to connect a power supply to the
device:
Make sure that terminal is not connected to power source.
Secure the 24VDC power wires.
Secure the functional earth ground wire to the functional earth ground terminal screw on terminal block.
Apply 24VDC power to the terminal.
Grounding
The optimum method for grounding electronic equipment is to ground it separately from other high-power systems
and to ground more than one unit of electronic equipment with a single-point ground. Following marked terminal is
provided with the unit for grounding:

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 8of 23
Product Specifications
This section of the manual provides detailed specifications of Web HMI series products, ordering part numbers,
operating conditions, environment and approvals.
Product Nomenclature / Ordering Part Number
Web HMI series has three models, depending on the display size. The detailed part number or ordering information
is as follows:
Display Specifications
Web HMI series products support high quality color TFT display range.
Size: 4.3" Color TFT, WQVGA Web Panel Analog Resistive Touch Screen
Resolution: 480 x 272pixels
Colors: 16M
Brightness: 400cd/m2
Backlight life: 30,000Hrs.
Size: 7” Color TFT, WVGA Web Panel Analog Resistive Touch Screen
Resolution: 800 x 480pixels
Colors: 16M
Brightness: 350cd/m2
Backlight life: 30,000Hrs.
Size: 10.1” Color TFT, WSVGA Color Web Panel Analog Resistive Touch Screen
Resolution: 1024 x 600pixels
Colors: 16M
Brightness: 350cd/m2
Backlight life: 50,000Hrs.
Plus

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 9of 23
CPU, Memory and Power Supply
Power Rating
Unit
Voltage
Current
Wattage
WP6043TN Plus
24VDC
220mA
5.5W
WP6070TN Plus
24VDC
250mA
6W
WP6101TN Plus
24VDC
350mA
8.5W
CPU: 2xARM Cortex-A9 upto
1GHz with GPU 2D/ GPU 3D
support
eMMC:4GB
RAM:1GB
Power Supply:
24VDC (±15%) with isolation
RTC: Built-in.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 10 of 23
Communication Interfaces
This section provides detailed information regarding various communication interfaces supported by the Web HMI
series.
Interfaces
WP6043TN Plus
WP6070TN Plus
WP6101TN Plus
USB Type C
1
1
1
USB Host
1x 2.0
1x 2.0
1x 2.0
RJ45/Ethernet
1x 10/100Mbps
1x 10/100Mbps
1x 10/100Mbps
RJ45/Ethernet Port
The Web Panel HMI series devices come with an in-built RJ45/Ethernet port. The RJ45 port is a shielded female jack
with link and activity LEDs.
Pin number
Signal
1
TX+
2
TX-
3
RX+
4
NC
5
NC
6
RX-
7
NC
8
NC
Type C USB Port
The Web HMI comes with a Type C USB port.
Pin number
Signal
1
GND
5
D-
6
D+
7
D-
8
D+
12
GND

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 11 of 23
USB Host Port
The Web HMI devices support one USB Host port that connect to a USB 2.0 compatible USB Flash drive.
This port can be used to upgrade the firmware and the browser.
Pin number
Signal
1
VCC
2
D-
3
D+
4
GND
Default Product Settings
Network Settings
DHCP
Brightness
Full Scale
Screen Touch Beeper
On
Default Language
English
Environmental Specifications and Approvals
Feature
Specifications
Operating Temperature
0 to 50°C
Storage Temperature
-20 to 85°C
Relative Humidity
10 to 95% non-condensing
Shock
IEC 60068-2-27
25g, 11ms, 6 shocks per axis,
total 18 shocks (X, Y, Z)
Vibration
IEC 60068-2-6
5 to 150Hz, 3g peak (X, Y, Z)
EMC
EN 55011 :2009/A1 :2010
EN 61131-2 :2007
EN 61000-6-2 :2005/AC :2005
EN 61000-6-4 : 2007/A1 :2011
Protection
IP66 rated for front panel
mounting
CE
Yes
UL
Yes (Class I Division 2)
RoHS
Yes

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 12 of 23
Powering up the Web HMI Series
To use the Web HMI as a browser, follow these steps to connect the device to a web-server.
1. Connect an Ethernet cable to the device.
2. Power up the device using 24VDC power supply by connecting it to the device’s pluggable terminal block.
3. If the browser or the firmware needs to be updated, connect a USB flash drive to the device.
Getting started with the Web HMI
Main Settings
Settings
Description
Device Settings button. This button is used to enter into device
configuration. Settings for Network, Calibration, Password, On-
Screen Keyboard, Time and Brightness can be accessed using this
button.
URLs Settings button.
Device Information button.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 13 of 23
Entering into device settings
1. At power on the user will see the screen as shown below. To change configuration of the device, press the button
within 5 seconds to enter into device configuration settings.
On clicking the button, the following screen will open up. This page is the home page of the device settings screen. The
screen shows the product part number along with selectable settings tabs on the left hand side.
Administrator Password
Clicking on any tab on the left hand side, the user will have to enter an admin password. The factory default password
for the device is ‘admin@123’. Clicking on the textbox brings up the On-Screen Keyboard (OSK). Enter the password
and click on OK to continue. If user click on the checkbox next to the assign password, it will display the password
characters.
[Note: Password must be at least 7 or more characters with 1 capital letter (0-9, a-z, A-Z).]

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 14 of 23
Network Setting
The first tab on the left is the Device Settings Tab. Clicking on it Network Setting screen will appear. On this screen the
IP of the device can be set. The device defaults to acquire a dynamic IP from the network when connected. In order to
provide a static IP, the user should click on the “Static” radio button and enter the IP Address, Subnet Mask and the
Default gateway manually by using the On-Screen Keyboard. The On-Screen Keyboard pops-up when the respective
textboxes are clicked.
[Note: On-Screen Keyboard- over the screen keypad.]
Time Settings
This setting is used to set the Time of the device.
On the network settings screen, click on the right arrow at the bottom right corner to view the Time settings. Time setting
will be on screen. The device defaults to acquire a NTP Time when connected. In order to provide a Manual Time, the
user should click on the “Manual” radio button and enter the Date & Time.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 15 of 23
Calibration Settings
This setting is used to set the calibration of the touch-screen of the device. The device is already calibrated at the factory
before shipping. In case re-calibration needs to be done, this setting screen can be used to calibrate the touch-screen.
On the Time settings screen, click on the right arrow at the bottom right corner to view the calibration settings.
1. Click on the Calibrate Touch-Screen button after the screen opens up.
2. On clicking the “Calibrate Device”button a dialog box opens up which asks for a final confirmation before
restarting the device in calibration mode.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 16 of 23
3. After entering into the calibration mode the following screens open up. Follow the directions given on the screen
to calibrate the touch-screen by touching and releasing the crosshairs.
1st stage 2nd stage
4th stage 3rd stage
5th stage
The device restarts with new calibrated touch-screen.
ATTENTION
ATTENTION: False Calibration
The calibration must be done correctly in order to avoid false calibration. To re-
calibrate a misaligned calibrated device, plug in a mouse into the device and repeat
the process.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 17 of 23
Password Setting
Use this screen to change the system password of the device. The factory set password is ‘admin@123’.
Click the right arrow on the bottom right corner of the Calibration settings screen. The following screen will open up.
1. Click on Current Password text box to enter the current system password using the On-Screen Keyboard. Click
on the New Password text box to assign New Password and enter a Confirm Password. If user click on the
checkbox next to the assign password, it will display the password characters.
2. Click on Save to save the changes or click on ‘Reset’ to clear all text boxes.
[Note: Password must be at least 7 or more characters with 1 capital letter (0-9, a-z, A-Z).]
CAUTION: If any other button is pressed before clicking on the ‘Save’ button, all
changes will be lost. Make sure to click on ‘Save’ before continuing.
Brightness Control
This option gives the user to select option of controlling the brightness of the Web HMI.
1. To open the Brightness control screen, click on the highlighted button from the Password setting screen as
shown below.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 18 of 23
2. The following screen will appear. Here the user can select the brightness of the screen as required by clicking
on the brightness control button.
On-Screen Keyboard Setting
This option gives the user to select option of controlling the Over Screen Keypad language.
1. To open the On-Screen Keyboard setting screen, click on the highlighted button from the Brightness Control
screen as shown below.
ATTENTION
ATTENTION: Home button and Left Arrow
The user can exit the settings screens by clicking on the Home button placed at the
bottom center of the screen.
The user can go to the previous screen by clicking on the Left Arrow placed at the
bottom left corner of the screen.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 19 of 23
2. The following screen will appear. Here the user can select the language for the On-Screen Keyboard by clicking
on the Language selection radio button.
Web Application
A Web Application button is provided below the Settings button, as highlighted below. On this screen the user can set
the URLs of the web servers to which the HMI would connect.
1. Click on the Web Application settings button.
2. Using the On-Screen Keyboard URLs can be entered by typing into the textboxes next to the radio buttons.
3. On the screen the user can enter up to 5 URLs or IP addresses of webservers.
4. After entering the URLs or IP addresses select the URL that the browser should open upon restart by clicking
on the respective radio button.
5. Click on ‘Save’ to save the changes before clicking on the ‘Home’ button.
6. Upon device restart the browser will browse the selected URL. If the URL or the IP address is not available,
then an Error 404: Page not found will be shown.

WP6 Plus Web HMI Series
© RENU Electronics Pvt. Ltd. Page 20 of 23
Device Information
This screen shows the information of the device. This is the only screen that is not password protected. This provides
information like the Product Name, the MAC Address, the IP Address, Subnet Mask and the Default Gateway address
of the device. To reach this screen, click on the third button from the top left.
Under the device information, the user will find the ‘Factory Reset’ button. After click on this button it will perform the
following functions:
1. Erase all URLs and IP addresses stored in the Web Application.
2. Erase the static IP if it was provided.
3. Reset the brightness to maximum.
4. Reset the password back to the factory password of ‘admin@123’.
After the above functions are performed, the device restarts with factory settings loaded.
Copyrights
The copyrights button on the right corner of the device information page displays the Open source licenses used in the
product.
ATTENTION
ATTENTION: Make of USB Flash drive
This device has been tested to work with Strontium® make USB flash drive.
This manual suits for next models
3
Table of contents