repabad Easy-in User manual

Please be sure to read these operating
instructions carefully before using the
Easy-in!
Make sure that you observe the care
instructions!
repaBAD cannot be held liable for
damages caused by inappropriate use.
BEDEASYIN E © 08/2009 repaBAD GmbH
Operating instructions
Easy-in

2repaBAD GmbH • We reserve the right to make technical changes
3
repaBAD GmbH • We reserve the right to make technical changes
Operation
The Easy-in is always in standby mode. The operation of the motorised
sliding door is currently in standby mode.
Operating the sliding door
Press the arrow keys (1 or 2) to move the sliding door in the direction
of the arrows. You must keep the respective arrow key pressed here.
The corresponding LED (3) lights up in green at the same time.
If you let go of the arrow key, the sliding door movement is interrupted
immediately. When closed, the sliding door initially moves in the opposite
direction and is then brought to a halt. Both LEDs (3) then ash in green.
If there is resistance when the sliding door is moved, the movement is
stopped and the door moves a little in the opposite direction and the
two LEDs light up in red. After the obstacle has been removed and an
arrow key pressed repeatedly, the door can be operated again
(as described above).
If there is resistance when the door is being closed (protection against
getting stuck), the door moves in the opposite direction and is then brought
to a halt. Both LEDs ash in green. Press one of the arrow keys once more
to operate the door again.
Electricity failure
Should the power for the bathtub be cut at any time (e.g. due to electrical
failure) and be re-commissioned (power supply functions again), one of the
two arrow keys („Open“ or „Close“) must be held pressed until the door is
fully open (the door is referenced and the zero point set).
1
3
2
Safety information
Danger to life! Danger of electric shock!
When taking a bath or showering, no electrical devices may be
operated in the bathtub or its proximity. Any contact between
an electrical device which is plugged in and water can cause a fatal
electric shock.
Children may not use the bathtub unsupervised.
If older or handicapped persons who have a limited scope of movement
use the bathtub, they should exercise special care.
Normally, anybody whose cardiovascular system, metabolism and nervous
system copes with normal everyday stress can bathe. If you have any
doubts, consult a doctor.
Do not use the bath if you have a cold, an infection, ulcers, suppurating
wounds or inammations until they are fully healed. Likewise after alcohol
consumption or directly after eating.
The specialist companies and the rst owner of the bathtub provide the
subsequent owners and users with the operating instructions.
Table of contents
Safety information 2
Operation 3
Keylock (child safety device) 3
Overview of the operator panel alarm indications 4
Care instructions for repaBAD Easy-in 7
Care instructions for repaCLEAR coated glass partitions 7
Warranty card 8

4repaBAD GmbH • We reserve the right to make technical changes
5
repaBAD GmbH • We reserve the right to make technical changes
Operator panel alarm indications
Code Cause Repair
Constant green
when the key
is pressed
Everything OK
The door moves as long
as the key is held.
Flashing green
when the key
is pressed
End position reached
Let go of the key.
Parallel green
ashing
Intermediate position
The door is in an inter-
mediate position, neither
fully open nor fully closed.
Use the „close“
or „open“ keys to move
to the end position.
Constantly red
Recognition
of an obstruction
The door has hit an obstruc-
tion and has therefore been
stopped and reversed.
Remove the obstruction
and use the keys to move
the door further in the
desired direction.
Zu
Auf
Parallel green/
red ashing,
acoustic alarm
Water stop
When lling the bathtub,
the door is not (fully) closed.
Water supply interrupted,
the door can only be
moved
in the „Closed“
direction.
Drain off water
or close the door.
Zu
Auf
Constantly red
when the key
is pressed
Bathtub lled
Opening not possible Drain off water fully,
wait approx. 1 minute
Parallel orange
ashing whilst
the key is pressed
Child safety device
activated.
Deactivate child
safety device
Keylock (child safety device)
If both LEDs ash in orange when an arrow key is pressed, the keylock
is activated. The door cannot be closed.
In order to avoid unauthorised operation of the door (e.g. by children),
you can activate the keylock.
To activate the keylock: press the „Open“ key when the door is open and
keep the key pressed. Press the „Close“ key too and keep both keys pressed
until you hear the acoustic signal.
To deactivate the keylock (no LED lights up): press the „Open“ key and
keep it pressed. Press the „Close“ key too and keep both keys pressed until the
fast ashing of the two LEDs (orange) stops and you hear the acoustic signal.

6repaBAD GmbH • We reserve the right to make technical changes
7
repaBAD GmbH • We reserve the right to make technical changes
Care instructions for Easy-in
Do not use cleaning agents which contain solvents, are aggressive
or abrasive! They damage the acrylic surface / glass partition.
Only use soft, non-abrasive and lint-free cloths for cleaning!
The acrylic surface / glass partition must be freed of abrasive dust etc.
before cleaning, e.g. by rinsing it with clear water.
Chemical drain cleaners may not be used.
After showering / bathing, clean the bathtub with a household cleaning
agent, rinse it out, clean the door and seal before opening it and rub dry.
Use a wiper to remove all water drops on the glass partition.
Clean the acrylic parts at regular intervals with anti-static acrylic and
plexiglass cleaner repaBAD „Spezial-Reiniger“ [special cleaner] (art. no. RR).
Repabad‘s acrylic material maintenance set (art. no. PF) is suitable for the
elimination of minor scratches in the acrylics.
Treat the seal in accordance with the frequency of use with sealant
cleaning agents.
Care instructions for repaCLEAR coated glass partitions
Do not use concentrated cleaning agents containing vinegar or citrus,
stainless steel cleaners, micro bre cloths or similar to clean glass partitions
coated with repaCLEAR!
We recommend repaCLEAR glass cleaner (art. no. GLASREIN) as the ideal
cleaning agent for repaCLEAR glass coated partitions. With repaCLEAR
glass cleaner, you can freshen up the glass renement.
Operator panel alarm indications
Code Cause Repair
Parallel red
ashing
Running time monitoring
A (partial) movement
of the door takes too long.
Systematic error.
Call the service
Alternately red
ashing
Sensor error
Plausibility check
for the level sensors failed.
Systematic error.
Call the service
1 LED
continuously red,
1 LED ashing red
Motor error
Motor is faulty Call the service

BEDEASYIN E © 08/2009 repaBAD GmbH
Technical hotline +49 (0) 70 24/94 11-88
repaBAD GmbH
Bosslerstr. 13-15
D-73240 Wendlingen
Tel. +49 (0) 7024/94 11-0
Fax +49 (0) 7024/94 11-30
www.repabad.com
repaBAD Schweiz GmbH
Unterer Rebberweg 129
CH-4153 Reinach
Tel. +41 (0) 61/71 39 13 4
Fax +41 (0) 61/71 10 82 6
www.repabad.com
✁
Warranty card
for repaBAD Easy-in
We grant a 5-year warranty on all acrylic parts for the repaBAD Easy-in
supplied by us provided the care instructions are observed and it is used
correctly and carefully in accordance with our general terms and conditions
of use. The warranty period for the Easy-in technology and electronics is 2
years. This warranty begins on the day of delivery by repaBAD. Any possib-
le
claim must be notied to the specialist tter from whom our product was
purchased, specifying the data provided below.
Delivered on: Customer‘s address:
Invoice no.:
Reason for complaint:
Specialist tter‘s address
Fitter‘s stamp / signature
Only send the warranty card in case of a complaint.
Table of contents
Other repabad Bathtub manuals
Popular Bathtub manuals by other brands

glass 1989
glass 1989 nubea 160/70 manual

Ella's Bubbles
Ella's Bubbles WALK IN BATHTUB S Series owner's manual

KARAG
KARAG K1202 Manual Installation

Aquatica Digital
Aquatica Digital PureScape 171 Mini Installation & Care Manual

BATO
BATO SM-4250 installation guide

Sterling
Sterling Bath/Shower Whirlpool System 76090110 Specifications