Resco StormCube User manual

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
1
Job# 5256
Product:
Resco StormCube
Product Code:
StormCubeWW
Installation Guide
Wall to wall version. January 2018
Step-by-step
Installation Guide
WALL TO WALL VERSION
JANUARY 2018

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
2
WALL TO WALL VERSION
IMPORTANT
SAFE PANEL
HANDLING
INSTRUCTIONS
DO NOT store in sun or rain,
or at high temperatures.
STORE INSIDE and keep in original
packaging until needed.
DO NOT slide panels - LIFT them!
3
DO NOT walk-over.
FIRST AID MEASURES.
Eye: Flush with owing water for at least
15 minutes, and if symptoms persist
seek medical attention.
Skin: Wash with mild soap and running
water. Seek medical attention if
symptoms persist. For cuts, clean
wound and apply antiseptic dressing.
Inhaled: Leave the dusty area.
USE CAUTION,
machined edges
may be razor
sharp!
Although Compact Laminate panels are tough and durable, they must be treated with
care. Panels can be damaged if not stored or handled properly during assembly.
3
Sheets can scratch if not stored
correctly - ensure free of dust and debris.
2 MAN LIFT.
Use suction lifting aids if available.
PERSONAL PROTECTION.
Eye: Dust resistant safety glasses should
be worn when machining.
Skin: Protective gloves should be worn.
Respiratory: A class P1 or P2 replaceable
lter or disposable half face piece
particulates respirator should be
worn when machining.
Flammability: Keep all storage and work
areas well ventilated to avoid a
buildup of dust that could ignite.
Take care
when
moving
panels
they can
be damaged
if not
handled correctly.

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
3
WALL TO WALL VERSION
CLEANING & MAINTENANCE
OF COMPACT LAMINATE
Compact laminate is engineered to last for many years.
We provide a 10 year guarantee on panel integrity.
The non-porous surface is easy to clean. The decorative surface
and resin core of Compact Laminate is impervious and resistant
to most commonly used cleaning agents and disinfectants.
Recommended cleaning agents
Surfaces can be easily cleaned with a dry or damp cloth and if necessary a mild
household cleaner.
•General cleaning: All-purpose cleaner (e.g. Ajax Spray & Wipe),
household cleaners, water or soap are recommended.
It is resistant to everyday wear and tear but needs some attention for harsh
conditions and staining.
•Surfaces and edges: Are easy to disinfect with hot water, steam and all common
types of disinfectant used in hospitals and professional applications.
•Spray paint: Turpentine or SPC 801.
•Permanent marker: Methylated spirits or SPC 801.
Never use any of the following on
the panels, aluminium or hardware:
•Do not use abrasive or polishing materials. Abrasive cleaners such as Jif Cream
Cleanser, Ajax (powder or liquid), Chemco, Brasso, Mr. Muscle oven cleaner or
Scrub free.
•Scourer pads, Wire wool or Sandpaper.
•High pressure water cleaning or steam cleaning of panels is not recommended.
•Neat Janola or other equivalent brands of bleaches.
•Any product containing strong mineral acid such as sulphuric acid, Battery acid,
hydrochloric acid, nitric acid or phosphoric acid. Commercial toilet cleaners, grout
removers, descalants, rust removers, bleach, etc.
•Care must be taken where cleaning agents or solvents are highly acidic or alkaline as
these may permanently damage the surface.
Ongoing Maintenance:
•The use of CRC or equivalent on hinges and indicator bolts is recommended at least
once every 3 months (sooner for challenging environments).
•An occasional re-nish of the exposed edges with an “off the shelf” wood-polish will
rejuvenate the original polished seen edges.
•Any chemicals should be washed off so that they don’t keep working.
•Finger prints and other such surface marks can be neutralised with a silicone spray
and a micro-bre cloth.
See our Web site:
www.resco.co.nz/product/multicom - Cleaning instructions
For removal of grafti – Please call our
customer service team 0800 800 950
IMPORTANT

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
4
WALL TO WALL VERSION
IMPORTANT
NOTES
•When screwing into compact you must
pre-drill.
•Use low setting on your drills when
screw xing into Compact Laminate.
Compact Laminate can break screws or damage
the head if your drill is
too powerful.
•Don’t use hammer drills when installing into
Compact Laminate.
•Compact Laminate and Aluminium can damage
if not stored or treated properly – take care
when you are moving sheets.
Larger sheets require 2-man lift.
•The system will be packed so division panels are
at the top and the doors are
at the bottom.
•Use Diamond tip drill bits for drilling
into tiles.
•Oversize Fascias – rivet inll in the middle (of
the 2 other rivets on the other side)
of the pedestal at the opposite side to ensure
that the inll can’t be moved.
Sit in place and ensure that all the doors are perfect
before nal rivet. Therefore you can adjust. Ensure
plumb both ways.
Tools needed
• Level
• String line
• Chalk line
• Stool or small step ladder
• Timber blocks (155 mm)
• Timber wedges
• Rivet tool
• 3.5 mm drill bit
• 5 mm Masonry bit
• No. 1 Square drive
• No. 2 Pozi-drive
• Drop saw
• Nylon hammer
• Circular saw
Step-by-step
Installation Guide
Follow the installation instructions
and reference numbered steps on the
illustrations.

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
5
WALL TO WALL VERSION
Step 1
Step 2
Step 4
Step 3
From the ‘Resco Shop Drawings’, mark Datum on
relevant walls.
Note: on our proprietary system the Datum is normally
1960mm.
Ensure that the lowest point in the oor is used for
the Datum line otherwise posts could be too long, the
system could be on an angle, or the Headrail height
could be too low.
From the ‘Resco Shop Drawings’, mark the distance
from the back wall to the front of the cubicles.
From the ‘Resco Shop Drawings’, mark the division
centres on the back wall.
a. Check location of toilets and ensure centered (these
are sometimes tted differently to the plans).
Fix back U-Channels (1748mm) centered on your marks,
52mm below the Datum line.
a. The U-Channels are predrilled. Ensure screws go
into wall frame.
Use (A) 8GA x 32 screws (with a (F) plastic
anchor if required).

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
6
WALL TO WALL VERSION
Step 6
Step 5
Mark centre location of ½ Stile using shop drawings
a. Place top of ½ Stile on datum line centred at this
mark and plumb.
b. Screw x ½ stile to wall through pre-drilled holes on
½ stile
Use (C) 8GA x 50 screws
Note: If ½ Stiles have hinges, the hinges will be tted
on the ½ Stile without the centre screw. Place top of
½ Stile on the datum line, plumb and screw x to wall
through all 3 centre hinge holes.
Mark a ‘front face’ chalk line on the oor.
a. Chalk line from the center of the ‘side wall ½ Stiles’.
b. Place division panels into the rear U-channels with
the adjustable feet underneath. Adjust them so they
are level.
c. Adjust division panels so they are -15mm from the chalk
line and aligned with the top of the U-Channel then x.
Rivet through one side of U-Channel, Use
3.5mm Drill but with a (D) Stainless steel pop
Rivets.
Note: Sometimes the back wall is not straight. This can be
ok as you can either trim the division panels as required, or
adjust the front face. Just ensure you remark the chalk line
and that it’s straight, ts and looks good.
Chalk line
Mark centre location of stile

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
7
Step 7
Step 8
From the Resco Shop drawings, mark the full stile
centres on the chalk line.
Note: make sure to leave enough pencil mark along the
chalk line to be seen from under the full stile footprint.
This is so you can ensure the panels will be centred.
Floor mounted bracket positions are located by placing
a small off cut of the Full stile over the full stile centres
you marked in the previous step. Ensure you have
the correct orientation, by checking the Resco Shop
Drawings to ensure the full stile is orientated correctly.
Then place the oor mounted bracket into position and
Fix in place.
Use 5mm Masonry drill bit in concrete
oor and 3.5mm drill bit in wood oor or a
diamond drill bit for tiles.
Place (F) plastic anchor in hole.
Secure oor block, using (A) 8gax32 screws.
Trim Style to fit
Step 9
Full-Stiles
Use a laser level (or string line) between the tops of the
½ Stiles.
a. Trim all full Stiles to height, by putting each full Stile
upside down over the appropriate oor mount, mark
and then trim.
Floor mount brackets located in position. (Indicative only. Not to scale.)
WALL TO WALL VERSION

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
8
13mm
Step 10
Push aluminium bead to click in place.
(use additional polymer as required).
Place left hand end Fascia in position and Screw x in
place, ensuring you leave a 2-3mm gap for the Aluminium
bead to slot in.
WALL TO WALL VERSION
Sit panel on notch with gap behind panel.
Aluminium bead in position
Use (A) 8GA x 25 mm screws.
Clip ½ Stile bead in place.
Use Silicone to hold in place.
Place the right hand side end fascia into position onto
blocks – just hold it in position for now.

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
9
Step 12
Step 11
Fix losely
Fix to Spigot
Fix to oor mount Bracket
Headrail - Sit in place. This may require trimming
as Headrails are supplied oversize. As Headrails are
predrilled, make sure any trimming is done at the correct
end - there will be a sticker to indicate which end.
a. Ensure the Headrail is touching the
walls perfectly.
b. Fix headrail to side ½ stiles, with screws through the
top, 20mm from each end.
Ensure you drill holes straight so you don’t drill
through the panel.
Use 3.5mm drill bit with (D) Stainless
Steel Pop Rivets.
Place the locating pin into the hole, place the template of
the stile over the pin, drill and x down compact block.
Place the rst Full-Stile over
the appropriate oor mount.
Check the Resco shop
drawings to ensure
that the full stile is
orientated correctly.
a. Make sure it sits on the oor with the
Stile mounted over the oor
bracket. (Not to scale).
Headrail connecting
into the Full Stile.
(Not to scale).
Full Stiles located in position over the oor mount brackets. (Indicative only. Not to scale.)
chalk line running through the centre of
the stile.
b. Fix the top (loosely) through the Headrail’s predrilled
holes into the Full Stile.
Use 14g x 65 pan head screws.
WALL TO WALL VERSION

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
10
Step 15
Insert
p
ocket infils
Step 16
Fix this side as well
Step 13
Step 14
Ma
y
need trimmin
g
Place the next full stile into position and x in place.
Check the ‘Resco shop drawings’ to ensure that the full
stile is orientated correctly.
Insert appropriate Fascia and align U-Channel with
corresponding division panel.
Apply 4 blobs of silicon in Stile pocket to prevent panel
rattling in the future.
a. Move Fascia (and division panel) sideways across
into xed Stile pocket.
b. Ensure pushed hard into Headrail and put block
under Fascia to maintain height.
c. Slip next Full-Stile onto the other side of the
Fascia.
Check the Resco shop drawings to ensure that the
full stile is orientated correctly.
d. Move the top-end in to position above the screw.
e. Fix loosely for now to Headrail.
Use 14g x 65 pan head screws.
Repeat for the remaining Stiles and Fascias.
Check the last Fascia before xing as it may
need trimming.
To trim use a tungsten tipped blade.
Tighten up all of the Headrail screws.
Fix Fascia panels in place, screw x Headrail into the top
of the full stiles.
Use a 3.5mm drill and x with (E)
8GA x 20 counter sunk screws.
Place Full-Stile pocket-inlls to ll pockets between the
nished oor and the bottom of the panels. These may
need trimming if Stiles have been shortened.
Clip into place.
Fix division panels
a. Ensure all division panels line up with the bottom of
each U-Channel.
b. Drill 4 x holes on one side of each U-Channel.
Use 3.5mm drill bit with (D) Stainless Steel
Pop Rivets 30mm and 600mm from the top
and the same from the bottom.
WALL TO WALL VERSION

Resco StormCube WW version. Step-by-step Installation Guide. January 2018
11
Resco Limited.
12 Kahu Crescent
Te Rapa Park, Hamilton 3200. New Zealand
Phone: 0800 800 950, +64 850 1025
Fax: +64 7 850 1026
(www.resco.co.nz)
©Resco April 2017
Step 18 Fit hardware
COAT HOOK
Line up the coat hook with the pre-drilled holes in the
doors and screw on.
Use (B) 8GA x 12 screws.
INDICATOR BOLT
Step 01 - Front Component Coat Hook
Step 02 - Diamond Back Plate
Step 03 - Inside Bolt
Step 04 - Coverplate, Knob & Keeper
Insert the green and red plate into the inside of
the front component of the indicator bolt.
Fix the front part of the indicator bolt to the outside of
the door using the diamond back plate on the inside of
the door.
Use 2 x 8g x ½ screws.
Insert the hexagon shaped spindle into the front plate
from the inside.
Check the indicator is green and then check the bolt
lock is in the Open position.
Screw the inside bolt component onto the inside of the
door over the Diamond Back Plate.
Use 4 x 6g x 20mm screws.
Check that the lock can slide back and forth smoothly.
In case it jams it means that the hexagon spindle is not
perfectly perpendicular. You will need to gently slide the
front of the indicator left/right.
Fix the indicator bolt in the pre-drilled position.
Step 17 Hang doors
Lining up the hinges attached to each stile with the
predrilled holes on the doors, hang the doors.
Use the supplied (B) 8GA x 12 screws.
WALL TO WALL VERSION
Step 19 Clean Panels
Clean all components, including pencil marks on
the oor and walls.
Sweep the oor and remove rubbish.
Wipe down with soapy water.
Then clip on the cover plate. Push on the knob and
tighten the grub screws with the allen key supplied.
A keeper will already be installed on the Stile.

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
1
Job# 5252
Product:
Resco StormCube
Product Code:
StormCube-R
Installation Guide
Return version. January 2018
Step-by-step
Installation Guide
RETURN VERSION (Only 1 side wall)
JANUARY 2018

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
2
RETURN VERSION
IMPORTANT
SAFE PANEL
HANDLING
INSTRUCTIONS
DO NOT store in sun or rain,
or at high temperatures.
STORE INSIDE and keep in original
packaging until needed.
DO NOT slide panels - LIFT them!
3
DO NOT walk-over.
FIRST AID MEASURES.
Eye: Flush with owing water for at least
15 minutes, and if symptoms persist
seek medical attention.
Skin: Wash with mild soap and running
water. Seek medical attention if
symptoms persist. For cuts, clean
wound and apply antiseptic dressing.
Inhaled: Leave the dusty area.
USE CAUTION,
machined edges
may be razor
sharp!
Although Compact Laminate panels are tough and durable, they must be treated with
care. Panels can be damaged if not stored or handled properly during assembly.
3
Sheets can scratch if not stored
correctly - ensure free of dust and debris.
2 MAN LIFT.
Use suction lifting aids if available.
PERSONAL PROTECTION.
Eye: Dust resistant safety glasses should
be worn when machining.
Skin: Protective gloves should be worn.
Respiratory: A class P1 or P2 replaceable
lter or disposable half face piece
particulates respirator should be
worn when machining.
Flammability: Keep all storage and work
areas well ventilated to avoid a
buildup of dust that could ignite.
Take care
when
moving
panels
they can
be damaged
if not
handled correctly.

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
3
RETURN VERSION
CLEANING & MAINTENANCE
OF COMPACT LAMINATE
Compact laminate is engineered to last for many years.
We provide a 10 year guarantee on panel integrity.
The non-porous surface is easy to clean. The decorative surface
and resin core of Compact Laminate is impervious and resistant
to most commonly used cleaning agents and disinfectants.
Recommended cleaning agents
Surfaces can be easily cleaned with a dry or damp cloth and if necessary a mild
household cleaner.
•General cleaning: All-purpose cleaner (e.g. Ajax Spray & Wipe),
household cleaners, water or soap are recommended.
It is resistant to everyday wear and tear but needs some attention for harsh
conditions and staining.
•Surfaces and edges: Are easy to disinfect with hot water, steam and all common
types of disinfectant used in hospitals and professional applications.
•Spray paint: Turpentine or SPC 801.
•Permanent marker: Methylated spirits or SPC 801.
Never use any of the following on
the panels, aluminium or hardware:
•Do not use abrasive or polishing materials. Abrasive cleaners such as Jif Cream
Cleanser, Ajax (powder or liquid), Chemco, Brasso, Mr. Muscle oven cleaner or
Scrub free.
•Scourer pads, Wire wool or Sandpaper.
•High pressure water cleaning or steam cleaning of panels is not recommended.
•Neat Janola or other equivalent brands of bleaches.
•Any product containing strong mineral acid such as sulphuric acid, Battery acid,
hydrochloric acid, nitric acid or phosphoric acid. Commercial toilet cleaners, grout
removers, descalants, rust removers, bleach, etc.
•Care must be taken where cleaning agents or solvents are highly acidic or alkaline as
these may permanently damage the surface.
Ongoing Maintenance:
•The use of CRC or equivalent on hinges and indicator bolts is recommended at least
once every 3 months (sooner for challenging environments).
•An occasional re-nish of the exposed edges with an “off the shelf” wood-polish will
rejuvenate the original polished seen edges.
•Any chemicals should be washed off so that they don’t keep working.
•Finger prints and other such surface marks can be neutralised with a silicone spray
and a micro-bre cloth.
See our Web site:
www.resco.co.nz/product/multicom - Cleaning instructions
For removal of grafti – Please call our
customer service team 0800 800 950
IMPORTANT

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
4
IMPORTANT
NOTES
•When screwing into compact you must
pre-drill.
•Use low setting on your drills when
screw xing into Compact Laminate.
Compact Laminate can break screws or damage
the head if your drill is
too powerful.
•Don’t use hammer drills when installing into
Compact Laminate.
•Compact Laminate and Aluminium can damage
if not stored or treated properly – take care
when you are moving sheets.
Larger sheets require 2-man lift.
•The system will be packed so division panels are
at the top and the doors are
at the bottom.
•Use Diamond tip drill bits for drilling
into tiles.
•Oversize Fascias – rivet inll in the middle (of
the 2 other rivets on the other side)
of the pedestal at the opposite side to ensure
that the inll can’t be moved.
Sit in place and ensure that all the doors are perfect
before nal rivet. Therefore you can adjust. Ensure
plumb both ways.
Tools needed
• Level
• String line
• Chalk line
• Stool or small step ladder
• Timber blocks (155 mm)
• Timber wedges
• Rivet tool
• 3.5 mm drill bit
• 5 mm Masonry bit
• No. 1 Square drive
• No. 2 Pozi-drive
• Drop saw
• Nylon hammer
• Circular saw
Step-by-step
Installation Guide
Follow the installation instructions
and reference numbered steps on the
illustrations.
RETURN VERSION

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
5
RETURN VERSION
Step 1
Step 2
Step 3
Step 5
From the ‘Resco Shop Drawings’ mark the division
centers on the back wall.
a. Check location of toilets and ensure centered
(these are sometimes tted different to the plans).
Fix back U-Channels (1748mm) centered on your marks,
52mm below the Datum line.
a. The U-Channels are predrilled.
Ensure screws go into wall frame.
Use (A) 8GA x 32 screws (with a (F) plastic
anchor if required)
There is a gusset already xed in the return Headrail.
On the ground slot the front Headrail into position and
x (like the return Headrail) ensuring a perfect mitre.
Take care not to scratch the Headrails.
Use (E) 8GA x 20 screws.
Hold Headrail in position to nd where side and return
(1795mm) ½Stiles go.
Balance the difference (if any) between both ‘side ½
Stile’ and ‘return ½ Stile’ and mark centers to ensure
perfect mitre cut.
Note: This adjustment allows for walls that are not at
right angles.
From the ‘Resco Shop Drawings’ mark the distance from
the back wall to the front of the cubicles.
From the ‘Resco Shop Drawings’ mark the Datum on
relevant walls. Ensure that the lowest point from the
marks on step one is used for Datum line and transfer
this to the relevant walls - otherwise posts could be too
long, the system could be on an angle, or the Headrail
height could be too low.
Note: on our proprietary system the Datum is normally
1960mm.
Adjust ends so
that the corner
mitre is perfectly
square with
the walls.
Step 4

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
6
Step 6
a. Fix ‘side ½ Stile’ and ‘return ½ Stile’ at predrilled
locations.
b. Ensure that the bead side of the extrusion is facing
back into the cubicles – so it looks best from the
front
Use (A) 8GA x 32 screws.
Note: If ½ Stiles have hinges, hold the ½ Stile in place, at
Datum, and mark on wall the centres of the hinges.
RETURN VERSION
13mm
Step 7
Place return panel on adjustable support blocks, ush
with the bottom of the ½ Stile. Screw x in place,
ensuring you leave a 2-3mm gap for the Aluminium bead
to slot in.
Use (A) 8GA x 32 screws.
Sit panel on notch with gap behind panel.
a. Plumb and Fix in place at ½Stile. Counter sink
screws through panel into ½Stile.
b. Clip ½Stile bead in place.
Use Silicone to hold in place.
CONTINUED NEXT PAGE

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
7
Step 7
RETURN VERSION
Aluminium bead in position
Step 9
Step 8
Fix Corner Channel
Fix corner channel to return panel, leaving a 2mm gap,
with 4 rivets.
Use 3.5mm drill bit with (D) Stainless Steel
Pop Rivets 30mm and 600mm from the top
and the same from the bottom.
Mark a ‘front face’ chalk line on the oor.
a. Chalk line from the centre of the ‘side wall’ ½ Stile
to the centre of the corner channel.
b. Place division panels into rear U-Channels with
adjustable support blocks underneath to make them
level.
c. Adjust division panels so they are -15mm from the chalk
line and aligned with the top of the U-Channel then x.
Rivet through one side use 3.5mm drill bit
with (D) Stainless Steel Pop Rivets 30mm and
600mm from the top and the same from the
bottom.
Note: Sometimes the back wall is not straight. This
can be ok as you can either trim the division panels as
required, or adjust the front face.
Just ensure you remark the
chalk line and that it’s
straight, ts and looks good.
CONTINUED FROM PREVIOUS PAGE

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
8
RETURN VERSION
Step 10
From the Resco shop drawings,
mark the centers for the oor mount on the chalk line.
Step 11
Centre the oor mounts in place and drill the 2 side
holes to x in place.
Use 5mm masonry drill bit in concrete
oor and 3.5mm drill bit in wood oor or a
diamond drill bit for Tiles.
Place (F) plastic anchor in hole. Secure oor
mount, using (A)8GA x 32 screws.
Trim Style to fit
Step 12
Full-Stiles
Use a laser level (or string line) between the tops of the
½Stiles.
a. Trim all Stiles to height, by putting each Stile upside
down over the appropriate oor mount, mark and
then trim.
Floor mount brackets located in position. (Indicative only. Not to scale.)
Step 13
Hold in place corner channel Fascia with one rivet ush
with the bottom and then plumb.
Use 3.5mm drill bit with (D) Stainless Steel
Pop Rivet 30mm from the top.
Sit in place the Return Headrail.
a. Ensure the Headrail is touching the walls perfectly.
b. Drill 3.5mm holes, 200mm apart through the head
rail and into the top of the return panel. Be careful
not to drill through the side of the panel.
Use a 3.5mm drill and x with (E) 8GA x 20
counter sunk screws.
Step 14
Install wall ½ Stile Fascia using Polymer as you did for
the Return panel in Steps 6 and 7.
Headrail - Sit in place.
a. Ensure the Headrail is touching the walls perfectly.
The mitre should be perfect from the earlier step.
b. Fix Headrail to side ½Stiles.
Use 3.5mm drill bit with (D) Stainless Steel
Pop Rivets.
Step 15

Resco StormCube-R version. Step-by-step Installation Guide. January 2018
9
RETURN VERSION
Step 16
Place the rst Stile over the appropriate oor mount
bracket.
Check the Resco shop
drawings to ensure
that the Stile is
orientated correctly.
Stile mounted over the
oor bracket.
(Not to scale).
Fix losely
Fix to spigot
a. Make sure it sits ush on the oor then rivet through
the Stile into the oor block.
Use 3.5mm drill bit with (D) Stainless Steel
Pop Rivets.
b. Fix the top (loosely) through the Headrails predrilled
holes into the Full Stile bracket.
Use 1 x (AA) 14g x 65mm Screw.
Headrail connecting
into the Full Stile.
(Not to scale).
Full Stiles located in position over the oor mount brackets. (Indicative only. Not to scale.)
FasciaDoor Door DoorFascia Fascia
Step 17
Place the next Stile into position and x in place. Check
the ‘Resco shop drawings’ to ensure that the Stile is
orientated correctly.
Insert appropriate Fascia and align U-Channel with
corresponding division panel.
Apply 4 blobs of silicon in Stile pocket to prevent panel
rattling in the future.
a. Move Fascia (and division panel) sideways across into
xed Stile pocket.
b. Ensure pushed hard into Headrail and put block
under Fascia to maintain height.
c. Slip second Stile onto the other side of the Fascia, by
placing it orientated correctly over the oor mount.
d. Move the top-end in to position above the coach
screw.
e. Fix loosely for now to Headrail.
Use 1 x (AA) 14g x 65mm Screw.
This manual suits for next models
1
Table of contents
Other Resco Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

PIP STUDIO
PIP STUDIO GARDEN DINING CHAIR quick start guide

Regalo
Regalo 1164 EW owner's manual

Rauch
Rauch 16293.5430 Assembly instructions

Tchibo
Tchibo 342 466 Assembly instructions

AMES
AMES CLOSETMAID Bamboo Laundry Hamper with Sliding... installation instructions

ROOMS TO GO
ROOMS TO GO Sofia Vergara NAJA BDPAT2HBQ Assembly instructions

Target
Target CAHRZLBKES Assembly instructions

Emmezeta
Emmezeta ALICANTE ATCF01 Assembling instructions

BUT
BUT TIME 4894223220842 Assembly instructions

Northbeam
Northbeam ADIRONDACK ADC0111100910 Care Instructions

Reer
Reer Guardino 700010 instructions

tikamoon
tikamoon Edos CUP0018 Assembly, Use, Maintenance Manual