REVELL SA1000 User manual

SA1000 Subwoofer Amplifier
Owner’s Manual

2SA1000 Subwoofer Amplifier
Owner’s Manual
TABLE OF CONTENTS
About Revel®................................................................. 2
About Your Revel®SA1000 Subwoofer Amplifier.... 3
Product Highlights .................................................... 3
What’s In The Box..................................................... 3
Unpacking...................................................................... 3
Front Panel Layout......................................................... 3
Rear Panel Layout ......................................................... 4
Connections.............................................................. 4
Equalization .............................................................. 4
Installation .................................................................... 5
Cooling Requirements................................................... 5
Connections/Amplifier .................................................. 5
Configurations/Wiring................................................... 6
Troubleshooting............................................................. 7
Specifications................................................................ 7
Warranty ....................................................................... 8
Congratulations and Thank You for purchasing your new REVEL®SA1000
Subwoofer Amplifier.
Please take the time to read the following installation and setup
information in order to optimize your the performance of your amplifier
and architectural subwoofer system.
ABOUT REVEL®
Since 1996, REVEL®has stood at the forefront of loudspeaker design
and performance. Backed by Harman International’s world leading
research and design facilities, REVEL®loudspeakers benefit from
cutting-edge resources such as:
• Multiple large anechoic chambers which allow for precise testing
and measurements.
• A multi-channel listening lab for double-blind, position independent
listening tests.
• A laser interferometer that enables detailed driver and cabinet
analysis.
• Finite element analysis, utilized for advanced loudspeaker modeling.
• A stereo lithography apparatus, which rapidly “builds” tooled parts.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding-
type plug has two blades and a third grounding prong. The wide blade or the
third prong is provided for your safety. If the provided plug does not fit into
your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket or table specified by
the manufacturer or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long
periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power supply
cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, or the apparatus has been exposed to rain or moisture,
does not operate normally or has been dropped.
15. Do not expose this apparatus to dripping or splashing and ensure that no
objects filled with liquids, such as vases, are placed on the apparatus.
16. The mains plug is used as disconnect device, the disconnect device shall
remain readily operable.
17. WARNING: Apparatus shall be connected to a MAINS socket outlet with a
protective earthing connection.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.
The lightning flash with arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of
uninsulated “dangerous voltage” within the product’s enclosure
that may be of sufficient magnitude to constitute a risk of electric
shock to persons.
Warning: To reduce the risk of electric shock, do not
remove cover (or back) as there are no user-serviceable
parts inside. Refer servicing to qualified personnel.
The exclamation point within an equilateral triangle is intended
to alert the user to the presence of important operating
and maintenance (servicing) instructions in the literature
accompanying the product.
WARNING: To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture. Operating Temperature
35˚C.

3
SA1000 Subwoofer Amplifier
Owner’s Manual
ABOUT YOUR REVEL®SA1000 SUBWOOFER AMPLIFIER
The SA1000 subwoofer amplifier is a high efficiency Class D
amplifier specifically designed to be used in conjunction with REVEL®
Architectural subwoofers. It is optimized to give the best dynamics
and frequency response of REVEL®Architectural subwoofers, and is
specifically designed to drive their highly reactive load impedances.
NOTE: The EQ and headroom management have been specifically
designed for REVEL®Architectural subwoofers! Use of the
SA1000 with any other subwoofers could lead to damage of the
subwoofer or the SA1000 amplifier. Contact your dealer or visit
www.revelspeakers.com for the latest list of models that can be
safely used with your SA1000 amplifier.
PRODUCT HIGHLIGHTS
• Wide dynamic range
• Low distortion and low noise
• 2 EQ modes (Customized for in-wall and in-ceiling subwoofers)
• User-adjustable Single-band PEQ (Room Equalization)
• Automatic Turn-On (detecting signal presence) and Turn-Off after 10
minutes with no signal
• Short-circuit and over-current protection
• Over-temperature compensation
• Two dual-banana output connectors for easy installation and
connection to REVEL®Architectural in-wall or in-ceiling subwoofers
(Maximum of 2 subwoofer modules per amplifier)
WHAT’S IN THE BOX
• 1 x SA1000 Subwoofer Amplifier
• 2 x Rack Mount brackets
• 4 x Screws for installing rack mount brackets
• 1 x SA1000 Owner’s Manual
• 1 x Power Cord
UNPACKING
Carefully unpack the amplifier and accessories. If you suspect damage
from transit, report it immediately to your dealer and/or delivery service.
Keep the shipping carton and packing materials for future use.
WARNING: Before you start to set up your amplifier, make sure
you read and observe the Important Safety Instructions found at the
beginning of this manual.
1. Power LED
The Power Indicator LED identifies the current state of the SA1000
amplifier. The amplifier has three different powered states:
• Red: Standby – the SA1000 automatically enters Standby if no signal
is detected from the system for 10 minutes.
• Green: On – the SA1000 turns on to the “On” state, or when a signal
is detected.
• No Light: Off - the AC mains power switch is in the off position or the
SA1000 is unplugged.
2. Volume Control
Adjusts the volume level of the amplifier.
FRONT PANEL LAYOUT
Figure 1: Front-panel controls and indicators
1 2

4SA1000 Subwoofer Amplifier
Owner’s Manual
The rear panel of the SA1000 amplifier, shown in Figure 2, contains the
following connectors and controls:
CONNECTIONS
1. Input
Input is made through RCA line level input jacks, Connect the outputs
of the preamplifier, receiver or surround processor to these connectors.
If you are connecting to a single LFE output, you can connect it to either
jack. If you need more sensitivity from the subwoofer/amplifier system,
then connect the LFE signal lead to a Y-adapter cable and connect one
output into each jack.
2. Output(s)
Two output connections with 5-way binding post terminals are provided.
Each binding post accepts standard 4mm banana connectors, crimp-on
lugs, pins or twisted bare wire through the post hole under the post nut
covers, and twisted bare wire around the metal post. Each output has a
minimum impedance of 8 Ohms (one B28W or B28C).
IMPORTANT NOTE: The SA1000 is not designed for use in Bridged
configuration.
3. Low Pass Crossover
The variable 50Hz – 150Hz low-pass crossover determines the frequency
at which the SA1000 blends to the main speakers.
NOTE: This control does not limit the frequency range of the main
speakers in the system. Adjust the Low-Pass Crossover control to
properly blend to the satellite speakers. When the blend is correct,
notes of instruments and voice in the crossover region should sound
correct in level; not too loud relative to the subwoofer frequencies or
satellite frequencies, but also not too soft. When the control is turned to
“LFE” the crossover is by-passed and all crossover settings are now set
in the Processor or AVR menu.
EQUALIZATION
The equalization controls tailor the amplifier’s response for your listening
position in your specific listening room. The parametric equalizer
includes variable controls to adjust Frequency, Bandwidth (or “Q”) and
EQ Level of one band of eq, as shown in Figure 3. To use these controls,
you first must set the EQ switch to “ON”.
Figure 3: Rear-panel equalization controls
NOTE: Specific measurement equipment is required to properly
adjust the Equalization controls. Your authorized REVEL®dealer
can make the appropriate measurements, using suitable
equipment to ensure optimal results.
4. EQ Frequency Control
This adjustment allows you to select the center frequency of the
particular problem area. The range is from 32Hz to 100Hz.
5. EQ Bandwidth Control
Sets the range of frequencies over which the equalizer will have an
effect. The range is from 0.1 octaves to 0.6 octaves.
6. EQ Level Control
Allows you to adjust how much boost or cut is applied to the selected
frequency by the EQ Frequency Control. This control adjusts from -12dB
to a maximum of +3dB.
7. Phase Switch
Adjusts the phase of the subwoofer’s output to the front speakers.
Proper phase adjustment can also depend on variables such as the
in-wall subwoofer placement and listener position. Set this switch for
maximum mid-bass output at the primary listening position.
REAR PANEL LAYOUT
Numbers in Figure 2 correspond with the numbered items in this section
Figure 2: Rear-panel controls and connectors
1 11
109876543
2

5
SA1000 Subwoofer Amplifier
Owner’s Manual
8. EQ On/Off Switch
Enables/Disables the parametric EQ controls (Frequency, Bandwidth,
and EQ Level, but not Phase).
9. “1 2”, or Subwoofer Type Switch
Selects the factory pre-programmed subwoofer type settings:
• Select the Type 1 setting for use with with the Revel®B28C
• Select the Type 2 setting for use with the Revel®B28W
10. AC Mains Power Switch
Connects and disconnects power from the AC input cord. During periods
of intermittent use, the power switch can be left On. It is recommended
to turn off the power switch for extended periods of non-use.
11. Power Cord Connector
Plug the supplied power cord into this connector and into a wall-
mounted AC outlet. Due to the current draw of the SA1000, accessory
outlets on the back of any audio/video components should NEVER be
used to power this product.
The power cord connector includes the fuse tray, located at the lower
side of the receptacle. If you need to gain access to the fuse, always
disconnect the unit from the AC source/outlet. Replace the fuse with the
same type, voltage and current rating specified.
100-120VAC Model: 10AH,250V
230-240VAC Model: 5AH,250V
INSTALLATION
CAUTION: Before you begin, make sure your amplifier is disconnected
from the power source and all level controls turned completely down
(counterclockwise).
Make sure the power source is adequate to supply the correct AC mains
voltage and current for the Revel®SA1000 amplifier. Be sure that your
amplifier operating voltage matches your available AC mains voltage.
To install the SA1000 in your cabinet/rack system, follow the steps below:
• If applicable and or required by the installation, attach the rack
mount brackets to each side of the front of the amplifier using the
screws provided. Refer to Figure 4
• Install the assembly into the cabinet using the mounting screws for
your rack through the rack mount brackets. For details of installation
into the cabinet, refer to the user guide of your cabinet.
Figure 4
COOLING REQUIREMENTS
With proper installation, your new Revel®SA1000 amplifier is designed
for continuous operation of your Revel®Architectural subwoofer, either
the B28W In-wall subwoofer or the B28C In-ceiling subwoofer.
Your Revel®SA1000 amplifier is equipped with a thermal protection
circuit, which will shut the amplifier off when it gets too hot. If you
experience thermal issues, several factors may be contributing to the
problem, including load impedance, air flow and ambient temperature.
To avoid impedance related heating, DO NOT USE any subwoofer other
than the recommended REVEL®Architectural subwoofers.
Air flow restrictions could be another factor. Always install the amplifier
allowing sufficient air flow around the unit, favoring natural convection.
The SA1000 works fine in a rack-mounted environment of conventional
design. You may have to experiment with positioning, as hotter
equipment below it will raise its ambient temperature. If you experience
it thermally cycling, then you may need to move it lower in your rack.
Ambient temperature can also be a factor as a higher room temperature
will start the SA1000 closer to its thermal limit than a lower room
temperature. If the room is excessively hot, either cool the room or use
the amplifier/subwoofer system at a cooler time.
CONNECTIONS/AMPLIFIER
CAUTION: NEVER make or break connections unless all system
components are powered off.
2 CHANNEL APPLICATION –
CONNECTING TO THE MAIN OUTPUTS
L
R
L
R
RECIEVER/PREAMPLIFIER
MAIN OUTPUT
INPUT
SA1000 INPUT PANEL
Figure 5
CONNECTION TO MAIN OUTPUTS
1. Connect a dual-channel RCA patch cable between Left & Right main
outputs of the receiver/preamplifier and to the respective INPUT
connectors on the SA1000 rear panel, as shown in Figure 5.
NOTE: This configuration applies to receivers with preamplifier
outputs or to preamplifier/subwoofer amplifier configurations
in which there are two sets of Main outputs. If the receiver has
jumpers from the Pre- or Main-Out to the Amp-in connectors
or if the preamplifier has only one set of Main-Out connectors,
a Y-adapter should be used to send the same signal to both the
main power amplifier and the subwoofer(s). Tape Out or Record
Out connectors cannot be used.

6SA1000 Subwoofer Amplifier
Owner’s Manual
CONFIGURATIONS/WIRING
SINGLE SUB CONNECTIVITY (B28W SHOWN)
CAUTION: NEVER make or break connections unless all system components are powered off.
Line level connection options to SA1000:
• Connect a pair of RCA cables to left and right main outputs of your receiver/processor to L and R inputs of the SA1000 amplifier
• Connect receiver/processor subwoofer output to either of the L or R inputs
VOLUME
SOURCE
SA1000
B28W
REAR VIEW
Figure 6
IMPORTANT: For B28W in-wall sub select EQ2. For B28C in-ceiling select EQ1.
DUAL SUB CONNECTIVITY (B28W SHOWN)
CAUTION: NEVER make or break connections unless all system components are powered off.
A A
VOLUME
SA1000
B28W
REAR VIEW
B28W
FRONT VIEW
(REFERENCE ONLY)
SOURCE
Figure 7
IMPORTANT: For B28W in-wall sub select EQ2. For B28C in-ceiling select EQ1.

7
SA1000 Subwoofer Amplifier
Owner’s Manual
TROUBLESHOOTING
CONDITION POSSIBLE REASON
Front LED is not On • No power to the amplifier: The amplifier is not plugged into the power receptacle. Make sure power cord is
plugged into a properly working AC power outlet.
• No power to the amplifier: AC Mains power switch is set to Off. Make sure Mains power switch is set to On.
• No power to the amplifier: Main fuse is blown.
IMPORTANT!
Always disconnect unit from the AC Mains before checking AC mains fuse section. The AC Mains fuse,
should not generally blow unless a malfunction has occurred. The fuse must be replaced only with the
exact type and rating of the fuse originally supplied and specified. If the fuse has been replaced but blows
again within a short time, disconnect all power immediately and contact your dealer for support.
Green LED but no sound or low
output sound level
• Input signal is not present or is at a very low input level; Check subwoofer level settings at the preamp or
processor.
• Volume control is turned down: turn the SA1000 front-mounted volume control clock-wise.
• Crossover control is set too low: Raise the crossover frequency by rotating the crossover control clock-wise.
Intermittent operation (front panel
led transitioning from green to red)
• Output connections are shorted: Check for shorts in the loudspeaker cables.
• Amplifier is in thermal protection: Refer to the “Cooling Requirements” section of this manual. Look for
ventilation restrictions and/or high ambient temperature.
SPECIFICATIONS
DESCRIPTION SPECIFICATION
Rated Output Power (RMS) into the minimum
impedance of 4 Ohms
700 Watts
Peak power 1500 W
Rated impedance 8 Ohms per speaker output
Minimum load impedance 4 Ohms
Model-Specific EQ 1: Only for Revel B28C; 2: Only for Revel B28W
Input Sensitivity to 1W @ 50Hz 16.3mVrms +/- 1dB (Single input driven) Gain=41.7dB
Input Overload (Both inputs driven) ≥2.0Vrms
Input Impedance > 10K Ohms
Low Pass Crossover range 50-150Hz
Auto Turn On Input Sensitivity @ 50Hz Typical 10mV
THD+N at 1W <0.3%
THD+N at Rated Output Power <1%
Signal-to-Noise ratio to 1W >65dBA
Minimum AC Mains power requirements 100-120VAC-50-60Hz Model: 700W, 5A
230VAC-50-60Hz Model: 700W, 3A
Power consumption (Standby) 0.5W
Height 3.50 in (88.90mm)
Width 17in (431.8 mm)
Depth 11.04in (280.3mm)
Weight 14 Lb (6.35Kg)
Features, specifications and appearance are subject to change without notice.

8SA1000 Subwoofer Amplifier
Owner’s Manual
LIMITED WARRANTY
Revel loudspeakers are warranted against defects. The duration of a warranty depends on the laws in the country in which it was purchased.
Your local Revel retailer can help you determine the duration and coverage of your warranty.
For more information please visit: REVELSPEAKERS.COM
Please visit REVELSPEAKERS.COM for additional language support on the user manual.
Veuillez visiter REVELSPEAKERS.COM pour obtenir le mode d’emploi en d’autres langues.
Para obter o manual do usuário em outros idiomas, acesse REVELSPEAKERS.COM
Ga naar REVELSPEAKERS.COM voor de handleiding in andere talen.
Gå til REVELSPEAKERS.COM for bruksanvisning på flere språk.
Если вам требуется дополнительные версии руководства пользователя на других языках, посетите сайт REVELSPEAKERS.COM.
別の言語に対応したユーザーマニュアルを読むには、REVELSPEAKERS.COMにアクセスしてください 。
사용자 설명서에 대한 추가 언어 지원은 REVELSPEAKERS.COM에서 확인하십시오
请访问 REVELSPEAKERS.COM 以获取其他语言版本的用户手册。
Visita REVELSPEAKERS.COM para obtener el manual de usuario de soporte en idiomas adicionales.
Weitere Sprachfassungen der Bedienungsanleitung findest Du unter REVELSPEAKERS.COM.
Si prega di visitare REVELSPEAKERS.COM per i manuali di istruzioni in altre lingue.
Jos tarvitset ylimääräistä kieleen liittyvää tukea käyttöohjeesta, käy osoitteessa REVELSPEAKERS.COM.
Gå ind på REVELSPEAKERS.COM for at se betjeningsvejledningen på flere sprog.
Gå till REVELSPEAKERS.COM för mer information om språk i användarmanualen.

Торговая марка: Revel
Назначение товара: Пассивная акустическая система
Изготовитель: Харман Интернешнл Индастриз Инкорпорейтед, США, 06901
Коннектикут, г.Стэмфорд, Атлантик Стрит 400, офис 1500
Страна происхождения: Китай
Импортер в Россию: ООО Внешторг-Юг, Россия, 171640, Тверская область, г.Кашин, ул.
Карла Маркса, д.57A
Гарантийный период: 1 год
Информация о сервисных центрах: http://absolut-audio.ru/Servis/ тел. +7 (495) 995-10-80
Срок службы: 5 лет
Номер документа соответствия: Товар не подлежит обязательной сертификации
Дата производства: Дата изготовления устройства определяется по двум буквенным
обозначениям из второй группы символов серийного номера изделия,
следующих после разделительного знака «-». Кодировка соответствует
порядку букв латинского алфавита, начиная с января 2010 года:
000000-MY0000000, где «M» - месяц производства
(А - январь, B - февраль, C - март и т.д.) и «Y» - год производства (A -
2010, B - 2011, C - 2012 и т.д.).
HARMAN International, Incorporated
8500 Balboa Boulevard, Northridge, CA 91329 USA
© 2016 HARMAN International, Incorporated. All rights reserved.
Revel and the Revel logo are trademarks of HARMAN International Industries, Incorporated,
registered in the United States and/or other countries.
Features, specifications and appearance are subject to change without notice.
For questions, assistance or additional information concerning any of our products,
call us at: (516) 594-0300 or (888) 691-4171. For technical support, submit your detailed inquiry
www.revelspeakers.com
Part No. 950-0546-001
产品中有害物质的名称及含量
部件名称 目标部件
有害物质或元素
铅(Pb) 汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI)) 多溴联茉(PBB) 多溴二苯醚
(PBDE)
电路板 印刷电路板,电路板上的电子零件(不包括特定电
子零件),内部相关连接线 X 0 0 0 0 0
框体 外壳,面板,背板等 X 0 0 0 0 0
特定电子零
部件 变压器,保险丝,大型电解电容,电源插座 X 0 0 0 0 0
附件 电线,说明书,包装等 X 0 0 0 0 0
本表格依据SJ/T 11364的规定编制
O:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572规定的限量要求。
在中华人民共和国境内销售的电子电气产品上将印有”环保使用期”(EPuP)符号。
圆圈中的数字代表产品的正常环保使用年限。
Table of contents