Reya BATVIEW 2 User manual

BATVIEW 2
State of charge
controller
DOPERATING AN
USERS MANUAL
12V-24V
Code REYA : 399032
UK

TO PREVENT ANY RISK
BEFORE OPERATION THIS MANUAL CONTAINS
VITAL AND ESSENTIAL INFORMATION. IN
ORDER TO AVOID ELECTRICAL SHOCKS OR
OTHER DAMAGE, THE OWNER SHOULD READ
AND UNDERSTAND THIS IMPORTANT
DOCUMENT BEFORE OPERATING THE
CHARGER.
In the event of any problems or misunderstan-
dings, please contact mdp electronics.
This equipment is not designed for use by people
(including children) with diminished physical, sen-
sorial or mental capacities or people without ex-
perience or knowledge of such equipment, unless
they have received prior instruction in the use of
the equipment from a person responsible for their
safety or are under the supervision of such a per-
son. Ensure that children are supervised in order to
prevent them playing with the device.
This equipment contains components that may
cause electric arcs or sparks, when connecting
cables, for example. To prevent any risk of re or
explosion, do not install this equipment close to
ammable materials, liquids or gases.
Installation precautions
An de prévenir tout risque de surchauffe ou de
dommage irréversible sur le matériel, veillez à
suivre de manière impérative et rigoureuse les
recommandations ci-dessous.
4This device must not be exposed to running
water, water spray or dust of any kind.
4Under no circumstances should this device be
seen as a toy.
4Therefore, it should not be left in the hands of
a child.
Connection precautions
To prevent any risk of electric shock or irreversible
damage to the equipment, you should comply
strictly with the following recommendations.
The installation to which the device is connected
must comply with the applicable regulations.
To prevent parasite heating, ensure the cable
cross-sections are correct and the connectors are
suitably tightened.
Activation precautions
To prevent any risk of electric shock during activa-
tion or operation, you should comply strictly with
the following instructions.
Obviously, the product must not be dismantled
and the housing assembled correctly.
This device complies with the applicable regula-
tions governing transmitted interference and im-
munity from external disturbances.
CONTENTS OF BATVIEW2 PACKAGING
Please check the contents when opening the
BATVIEW packaging
Batview2-rev 01Batview2-rev 01
UK
TO PREVENT ANY RISK
4A VISION 5 housing and its
graphic display
4Chrome plated trim

GENERAL CHARACTERISTICSCONTENTS OF BATVIEW PACKAGING
Batview2-rev 01Batview2-rev 01
UK
4A angled connectors
10 points
4A angled connectors
6 points
4A 300A 100mV shunt
4A temperature sensor
4A bag of xing screws
4A user manual
The Peukert coefcient allows the actual capacity
of a battery to be estimated. For example, a ca-
pacity of 100Ah is applicable for a C/20 discharge
rate, i.e. 5A per hour for 20 hours at an ambient
temperature of 20°C. However, this same battery
will provide less than 100Ah if the amperage used
exceeds 5A, or more if the amperage is lower.
It is therefore an intelligent battery management
system, which is able to automatically adapt to
any consumption or charge on one or two house
batteries, in such a way as to provide an extre-
mely precise indication of the remaining charge
percentage.
The BATVIEW2 is easy to connect and automatical-
ly recognises a 12V DC or 24V DC supply voltage
when it is powered on.
The BATVIEW2 is equipped with a non-volatile me-
mory allowing the conguration settings to be
stored, even when there is no power, when it is
reactivated.
The BATVIEW2 is not sensitive to cycling effects as
it automatically detects oating mode, which
means that the batteries are fully charged. It is
therefore not affected by measurement drift over
the course of successive charging and dischar-
ging cycles, which, for other management sys-
tems on the market, results in a need to comple-
tely reinitialise the charge status.
The shunt supplied is made from a special alloy,
which allows a voltage drop, calibrated in mV
(converted into amps by the management sys-
tem), to be measured. This value is etched on the
shunt as is the maximum amperage that can ow
through it. This maximum amperage is 300A for a
maximum of 5 minutes. The permanent ampera-
ge that can ow through this type of shunt is two
thirds of this value (200A).
GENERAL CHARACTERISTICS
The BATVIEW2 is a battery management system
that allows the voltage of 4 different sets of batte-
ries and the amperage of 2 different sets of bat-
teries to be measured (1 shunt supplied, a second
optional shunt is available).
A calculation algorithm based on the Peukert
exponent allows the charge percentage for two
sets of batteries to be displayed (if a second op-
tional shunt is used).

Batview2-rev 01
INSTALLATION GUIDE
Batview2-rev 01
UK
INFLUENCE OF THE PEUKERT EXPONENT:
The Peukert exponent allows the life of a bat-
tery, which is not linear, to be better estimated.
In the example opposite, for a 350A bat-
tery, with a discharge capacity of 20 hours
(C20) stated by the battery manufacturers,
we could actually expect use of 17.5A per
hour for 20 hours (in green on the graph).
If this discharge was linear, it could be argued
that in 10 hours we could obtain 35A per hour, ex-
cept that in reality, the result is 9 hours, the Peukert
exponent allowing this to be determined. The re-
maining capacity, according to the BATVIEW2, ex-
pressed as a charge percentage, is therefore as
accurate as possible compared with the reality.
GENERAL CHARACTERISTICS
Quick installation guide
15 mm
72 mm
73 mm
C lic

Batview2-rev 01
UK
CONNECTIONS
Batview2-rev 01
INSTALLATION GUIDE
List of terminals PRECAUTIONS TO BE TAKEN FOR INSTALLATION
4Allconnection errors(polarityreversalsinparticu-
lar) cause irreversible damage to the equipment.
Youshould,therefore,payparticularattentiontothis.
4For the measuring wires for each shunt (ri-
ght hand terminal 1&2, 9&10), use a shielded
twisted pair cable (otherwise there is a risk of
measurement being frozen), tin-plated with ring
terminals (Ø 4 mm). Use the same pair for the 2
measuring screws (– and +) for the same shunt.
4A cross-section of 1 mm2, if possible tin-pla-
ted, is recommended for the other connected
wires. The use of shielded cable is not necessa-
ry in this case, except if there is the potential for
disturbance by the wiring for other equipment.
4 The external shunt for current measure-
ment must be positioned as close as possible
to the positive on the battery, i.e. the + BAT.
4An error in the direction of the 2 jumper wires
between one of the shunts and the BATVIEW2 will
result in an error in the direction of the current, i.e.
an arrow pointing down during charging and up
during discharging, as well as incorrect informa-
tion on the quantity of power remaining. Simply
reverse the 2 wires in question in order to restore
the correct direction and resolve the problem.
Dry alarm contact
(normally open)
Dry alarm contact
(common)
Dry alarm contact
(normally closed)
BAT.2 temperature sensor
(no direction)
Common temperature
sensors for BAT.1 and 2
BAT.1 temperature sensor
(no direction)
Wiring :
SHUNT.1, measuring screw on
battery 1 side
SHUNT.1, measuring screw on
the distribution side
Common negative or ground
BAT.1, SHUNT.1 measuring
screw on the distribution side
BAT.3, positive terminal for
battery 3
BAT.4, positive terminal for
battery 4
BAT.2, SHUNT.2 measuring
screw on the distribution side
Not used
SHUNT.2, measuring screw on
the distribution side
SHUNT.2, measuring screw on
battery 2 side
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6

INSTALLATION
Batview2-rev 01 Batview2-rev 01
INSTALLATION UK
1 SHUNT BATVIEW2 WIRING

INSTALLATION
Batview2-rev 01 Batview2-rev 01
INSTALLATION UK
2 SHUNTS BATVIEW2 WIRING

TECHNICAL SPECIFICATIONS USE
Batview2-rev 01 Batview2-rev 01
UK
Power supply
Voltage 12V DC or 24V DC (+/-25%), automatic
selection
Consumption 10mA to 30mA (Alarm) depending on the
operating mode
Display
Type of display OLED graphic display
Selection mode 5-button keypad
Alarms
Battery under-
voltage
Active as soon the voltage of BAT.1 2 3 or 4
< 11V (or 23.5V)
Can be set at
between 10V
and 12V (or
between 18V
and 24V)
Active dès que la tension de BAT.1 2 3 ou 4
> 16V (ou 32V)
Battery overvol-
tage
Active as soon as the voltage of BAT.1 2 3
or 4 > 16V (or 32V)
Battery tempe-
rature
Active as soon as the temperature of BAT.1
or 2 > 60°C
General
Battery capacity Between 30 and 5000Ah
Operating t° -10°C to +50°C
Storage t° -20°C to +70°C
Relative humi-
dity 10% to 70% without condensation
Circuit board
moulded and
protected
Instrument à encastrer Ø 93mm
Presentation Instrument for embedding/mounting Ø 93
mm
Housing Ø 72 mm (use a Ø73 mm hole saw)
Depth 30 mm
(including
connections)
93 x 30mm
Mounting 4 screws supplied
Overall dimen-
sions (Ø x D) 93 x 30 mm
Weight < 500 g
Connections Batteries and shunts by 10-point screw
terminal for wires of 1.5 mm2 max
Shunt 300A 100mV
Temperature
sensor
NCT moulded into a Ø 8 mm terminal, to be
attached to the battery terminal
Tested settings
Battery voltage 8V DC to 35V DC (measuring accuracy
+/-2%)
Battery current Permanent +/-350A (measuring accuracy
+/-5%)
Battery tempe-
rature
-10°C to +100°C (measuring accuracy
+/-5%)
Remaining bat-
tery life 0% to 100% (measuring accuracy +/-10%)
IMPORTANT when rst powered on
Disregard the initial information provided on the
basis of factory settings.
Adjust the type and capacity settings for different
sets (see SETTINGS MODE).
For increased accuracy when measuring current,
it is necessary to reset the current. To do this, en-
sure that no current is owing through the shunt
or shunts (no battery power consumption or char-
ging in progress).
Disconnect then reconnect the BATVIEW2.
The BATVIEW2 produces an estimate of the remai-
ning capacity, in Ah, by measuring the no-load
voltage of the batteries. This is only an initial esti-
mate.
To completely initialise the device, simply per-
form a rst charging cycle, preferably by using
the built-in charger. 100% initialisation becomes
effective once the batteries have been charged
(VBAT > 13.2V or 13.6V depending on the chosen
technology and once the charging current has
been reduced to zero).

USE SETTINGS MODE
Batview2-rev 01 Batview2-rev 01
UK
Settings mode
Factory settings (default settings):
4 Temperature expressed in degrees Celcius.
4A single set of batteries.
4Capacity of house batteries: 340Ah.
4 Type of shunt: 300A.
4Low battery voltage alarm: 11.0V.
4 Type of house batteries: With free electrolyte
(FREE)
Factory settings are operational until the user en-
ters his/her own settings.
To save any changes, quit by pressing and holding
the SET button. The conguration settings are sa-
ved in a non-volatile memory, as a replacement
for the factory settings.
These settings will, therefore, be automatically
applied when the device is next powered on.
It should be noted that the device automatically
leaves settings mode 45 seconds after the last
time the SET button is pressed without saving the
modied settings in a memory.

USE USE
Batview2-rev 01 Batview2-rev 01
UK

ALARMS ALARMS
Batview2-rev 01 Batview2-rev 01
UK
Set the Alarme mode
The device switches to Alarm mode when it de-
tects
4An undervoltage fault on any one of the 4 sets
of batteries.
4An overvoltage fault on any one of the 4 sets
of batteries.
4A temperature fault on sets 1 or 2.
4A low capacity fault on sets 1 or 2.
This mode is signalled by a ashing display indica-
ting the type of fault detected.
This mode results in the closure of an RCT dry loop
(terminals 1, 2, 3). The maximum switchable cur-
rent for the dry loop relay is 1A at 36V DC max.:
Return to “Normal” mode is automatic as soon as
the fault has disappeared.
Pressing “SET” allows you to momentarily return
(for 10 seconds) to “Normal” mode to allow you
to view various settings. If the fault persists, a re-
turn to “Alarm” mode is automatic.
Batteries 1 and 2
*ALARM* BAT(No.)
Vbat LO Battery undervoltage alarm (No.)
*ALARM* BAT(No.)
Vbat HI Battery overvoltage alarm (No.)
*ALARM* BAT(No.)
Temp HI Battery temperature alarm (No.)
*ALARM* BAT(No.)
Capa LO Battery low capacity alarm (No.)
*ALARM* BAT(No.)
CTN 1 T° sensor battery fault alarm (No.)
Batteries 3 and 4
*ALARM* BAT(No.)
Vbat low Battery undervoltage alarm (No.)
*ALARM* BAT(No.)
Vbat high Battery overvoltage alarm (No.)
BATVIEW2

For further information or assistance,
please contact:
REYA SAS
2599 Route de la Fènerie
06580 Pégomas
FRANCE
Tél : (33) 0 493 904 700
Fax : (33)0 493 902 440
www.reya.com
Table of contents
Popular Controllers manuals by other brands

Honeywell
Honeywell ML6284 Product data

Spa-Quip
Spa-Quip SPA Power 2000 user guide

Panasonic
Panasonic AWRP605P - MULTI FUNCTION CONTROLLER operating instructions

AL-KO
AL-KO ATC-AL-KO manual

elsner elektronik
elsner elektronik KNX eTR 205 Light Installation and adjustment

Felix Instruments
Felix Instruments AccuStore F-901 manual