VIP Vision INTKIT-A1 Intercom Installation Manual - Version: INT-A1-Q20121
6
6. Wiring & Power
Wiring Specication
Cable Specication
Power Specication
• Port A of the indoor monitor can be
connected to Port C of another indoor
monitor.
• Port B of the indoor monitor can be
connected to Port D of another indoor
monitor.
• Port A of the indoor monitor cannot be
connected to Port B or D of another
indoor monitor.
• Port C of the indoor monitor cannot
be connected to Port B or D of
another indoor monitor.
• For a transmission distance of <= 50m use a 0.75mm² 4 Core cable.
• For a transmission distance of >50m use a coaxial cable.
• The Kit includes a 12VDC 2A Power supply suited for a one Door Station to one Monitor
setup.
• Each device requires 12VDC 1A power.
• If you wish to add additional Door Stations or Monitors, replace the Power Supply with one
with the following output:
2 Devices 12VDC 2A
3 Devices 12VDC 3A
4 Devices 12VDC 4A
5 Devices 12VDC 5A